Page 1
MILLENNIUM Operation Manual SF822B Blood Pressure Monitor • Welcome to use MILLENNIUM Microcomputer Blood Pressure Monitor Series. • Please read the Manual carefully before use so as to operate the Blood Pressure Monitor correctly. • Please retain this manual for future reference.
Page 2
Foreword Hypertension (High Blood Pressure) is one of the three major diseases that are of great danger to mankind. It is known as the INVISIBLE KILLER. The higher the blood pressure, the higher the incidence of the heart disease or incidental cerebrovascular (apoplexy) disease.
Page 3
Blood pressure values change is the same by measuring wrist or upper arm. Therefore, one can monitor the change of his blood pressure values by measuring wrist blood pressure. Blood pressure changes throughout the day and even without feeling, body blood pressure will change ranging from 30mmHg-50mmHg according to body tension or relaxation state.
Page 4
(such as wrist or upper arm), different blood vessel wall thickness as well as different measurement time will probably generate different measuring results. SF822B It uses the Oscillometric method of measurement and automatically pressurizes and measures blood pressure and is capable of displaying minor changes of the blood pressure measured.
Page 5
Special Features of SF822A Microcomputer Wrist Blood Pressure Monitor All in one compact unit and easy to be portable. Memory function for storing 30 measurements for 3 persons including measured time, total 90 memories. Query function to view saved pressure data available, helping you constantly monitor your blood pressure.
Operation Guide Batteries Installation 1. Remove the battery compartment cover as illustrated by sliding the cover in the direction of the arrow. 2. Insert the batteries as per the polarity indicated inside the compartment. 3. Replace the battery cover. - 6 of 35 -...
Page 8
Caution: 1. Please remove batteries when unit is not in use for extended periods. 2. Replace promptly with new batteries in case low battery indicator is displayed on the LCD (must be two NEW AAA size batteries of the same brand). 3.
Page 9
Time Display and Set 1. Time Display When the unit is on, the system can display time and date except for query and save mode. Day/Month, Year is in the left lower corner of the screen such us 18/01 2004 09:28.
Page 10
The detailed time set process is as following procedures. Turn on the unit after replacing batteries. The screen time display is 01/01 (day/month), 2000(year) and 00:00(hour: minute). Moreover, the first character of “day” is flashing and by then “day” can be set by pressing MODE/+ key. After pressing set key to confirm, the second character of “day”...
2003, the screen will display “EE”. Please power on the unit and re-set time. Remark: If time set is not finished, Measure, Save, Query functions shall not be operated; when the device is switched on again, time set is still needed. Measuring Blood Pressure Fastening the Wrist Holder 1.
Page 12
lead to inaccurate readings. 2. The upper end of the unit should be located about 5mm to 10mm away from the palm base line and the centerline of the unit should be in line with the middle finger as shown in the figure.
Page 13
5. If the left hand wrist cannot be used due to reasons such as injury, sprain etc, you may use your right hand wrist following the above procedure. - 12 of 35 -...
Page 14
Posture for Measuring Be seated as shown while measuring blood pressure. 1.Place your left arm with the unit wrapped around your wrist gently on a table . 2. Place your forearm on the plastic case (the packing case of the unit ) as illustrated, making the center of the Wrist Holder in the same horizontal level as that of your heart.
Page 15
Do not speak and do not touch the monitor when measuring is taking place. Your blood pressure readings displayed may be higher than normal under the following circumstances: a) if you measure immediately after drinking alcohol or smoking, having meals or after a strenuous physical workout b) if you are stressed out, have mood swings or have had inadequate sleep...
Page 16
2. After about one second , the air relief symbol begins to flash, indicating the Blood Pressure Monitor is deflating the residual air in the Wrist Holder. 3. Upon the completion of air deflating, you will hear the buzzer beep and meanwhile the air relief symbol will disappear.
Page 17
setting of the upper limit of pressurization is not activated by the user for 3 seconds, the unit will automatically commence to pressurize. Pressurizing symbol will be displayed and the air pump will automatically inflate and pressurize the Wrist Holder and the system enters the measurement mode. The MODE key and SET key will not respond to operation before the completion of measurement.
Page 18
pressure levels set as follows, in mmHg unit: 180, 240 and 290, totaling 3 grades. 6. Upon the completion of pressurization, the air pressure inside the Wrist Holder will decrease automatically. A buzzer accompanied by flashing of the symbol on the Display Window indicates the beginning of the measurement of your blood pressure and pulse.
Page 19
the air pressure inside the Wrist Holder descends below 5mmHg, and meanwhile, the symbol will appear on the Display Window. And then, your blood pressure values as well as pulse will show upon the screen alternately (blood pressure and pulse displayed about 3.5 seconds and 2 seconds respectively).
Page 21
The basic blood pressure is your blood pressure taken when you are at your calmest, both mentally and physically. Since it is the basic index used when assessing the current state of your health, due importance should be accorded. This basic blood pressure should be measured ideally under the following conditions: 30 minutes to one hour after waking up (before breakfast) At room temperature of 15 degrees to 25 degrees Celsius...
Page 22
dramatically different, and it is caused by changed volume of blood flow resulted from deformed blood vessels upon pressure (particularly common for the old because of the poor flexibility of their blood vessel, their high blood viscosity as well as low recovery speed). Generally, your blood pressure value taken in a hospital is higher 20mmHg-30mmHg than that taken at home.
Save, Inquiry and Clear The SAVE function can record the high blood pressure (systolic) value, low blood pressure (diastolic) value, pulse and measured time upon the completion of measurement by pressing MODE key to select SAVE function followed by pressing SET key to confirm SAVE function. The system will not respond to SAVE function other than in the above situation even if the MODE key is pressed down to select the SAVE function followed by pressing SET key to confirm.
Page 24
can continue to press MODE key to save the second (NO.2) or the third (NO.3) measurement. It can save measured pulse, systolic, diastolic values and measured time only after pressing set key again. The system automatically chooses saving order and can save 30 measurements for each one at most.
Page 25
screen. The system is in command waiting status and press MODE key to select query measurements function. When the mode indication QUE displays, NO.1 will appear on the screen and indicate to query the first person’s measurements. You can choose to query the second or the third person’s measurements by pressing MODE key continuously.
Page 26
numbered 30 set of saved values has thus been displayed, pressing SET key once again, the system will display saved values numbered 1 again. Further pressing of SET key will again display the values at number 1 and so on cyclically. Clear Saved Measurements When the system is in command waiting status, press MODE key to select clear function.
Page 27
measurements. Remarks: 1. The saved data will still be kept in the system when the machine is turned off and then on or after the batteries are replaced. The system will appear 0 in case no data has been stored and QUE function is selected.
Page 28
Error Display Display Cause Treatment Release the Wrist With Noise Holder and Re-wear it for another measurement. Your wrist, finger or body moved Keep calm & quiet for 5 minutes or you talked and measure again. while measuring Wrist Holder Unbutton sleeve and wrap unit worn over shirt directly over the wrist.
Page 29
Upper Limit for Set a higher upper limit and Pressurization measure again. For e.g. if the upper limit was earlier set to High Enough 180, reset this to the next higher limit, 240. Faults & Causes Fault Treatment Systolic Blood Pressure Value Wrong Wrist Holder Location, too High while Diastolic Blood or Wrist Holder incorrectly...
Page 30
People tend to have subtle Difference in readings when psychosomatic changes in measured at the doctor’s clinic the presence of a doctor, and identical results are rare. No display when turning the Battery used out or wrong machine on by pressing installation of the batteries.
Page 31
Maintenance & Operation Precautions DO NOT inflate the unit without drop or give a strapping it on your wrist. DO NOT strong shock to the unit. - 30 of 35 -...
Page 32
DO NOT store in extremely low(less attempt than 0°C) or high (more than 60°C) disassemble the unit. temperature. Do not expose to moisture. - 31 of 35 -...
Page 33
DO NOT bend the Wrist Holder direction opposite to its shape. Warranty will be void if any of the above occurs. - 32 of 35 -...
Page 34
Specifications SHENGFU Microcomputer Wrist Name Blood Pressure Monitor Model □SF822B Large Digital Liquid Crystal Display Display Mode (LCD) Pressure: 0 - 37.3kPa Measurement Range ( 0 - 280mmHg ) Pulse: 40-200 Beats/Min Pressure: ± 0.4kPa (± 3mmHg ) Accuracy Pulse: ± 5%...
Page 35
Maintenance Temperature: 0°C-40°C Temperature & Relative Humidity (RH)≤80% Relative Humidity (RH) Airpressure:50kPa--106kPa airpressure 375mmHg—795mmHg Packing Dimension 100mm×83.3mm×88mm(L×W×H) Guarantee MILLENNIUM blood pressure monitor is guaranteed for 2 years from date of purchase. - 34 of 35 -...