QD Dynamics Pi HSC816 Programming And Installation Manual

Home security controller

Advertisement

Home Security Controller
Programming and Installation Manual
Release Versions
R1.00
R1.01
This document and product are copyrighted and all rights are reserved.
Pi HSC816 Installation Manual - Revision Beta
Pi HSC816
Release History
First production release
Second production release
QD Dynamics (Pty) Ltd
Kyalami Business Park
Kyalami, Midrand 1685
PO Box 888
Wendywood, 2144
Tel:
(011) 996-4400
Fax: (011) 466-1878
Date
18-08-2010
5-02-2011
1

Advertisement

Table of Contents
loading

Summary of Contents for QD Dynamics Pi HSC816

  • Page 1 Pi HSC816 Installation Manual - Revision Beta QD Dynamics (Pty) Ltd Kyalami Business Park Kyalami, Midrand 1685 PO Box 888 Wendywood, 2144 Tel: (011) 996-4400 Fax: (011) 466-1878 Pi HSC816 Home Security Controller Programming and Installation Manual Release Versions Release History Date R1.00...
  • Page 2: Table Of Contents

    Pi HSC816 Installation Manual - Revision Beta TABLE OF CONTENTS Introduction Terminology Arming Options Arm when faulted Auto Re-arm Quick arm Quick bypass Siren alert options Bus Line Transceiver Adding codex remotes Adding wireless detectors Connection Codex Remotes Adding or deleting remotes...
  • Page 3 Pi HSC816 Installation Manual - Revision Beta Programming levels Siren Options Alert on keypad arm Alert on remote away arm Alert on remote home arm Siren timer Siren trip count Siren beep on exit time expired Timers AC fail Auto test delay...
  • Page 4: Introduction

    Pi HSC816 Installation Manual - Revision Beta Introduction: The PI HSC816 is a South African designed and manufactured Security System, carrying full ICASA licensing and complying with all safety regulations and specifications. Features: 8 -16 programmable EOL or wireless or a combination of hardwire and wireless per zone.
  • Page 5 Pi HSC816 Installation Manual - Revision Beta Congratulations on your purchase of the PI HSC816. The South African designed and manufactured solution to all your electronic security requirements. Please take the time to read and familiarize yourself with the terms used throughout this manual.
  • Page 6 Pi HSC816 Installation Manual - Revision Beta Instant - A zone or input will create an immediate alarm condition when armed. Keypad - The user interface to the control panel, from which all commands and functions are carried out. Keypad tamper - After 21 incorrect key depressions on the keypad, the system will go into a keypad tamper condition.
  • Page 7 Pi HSC816 Installation Manual - Revision Beta Motherboard layout: AC +……………..AC input maximum 16.5V 40va AC -………………Negative to be taken from any negative (Earth) ....This must be connected to building earth were possible, alternately to mains earth AUX 12V .... 12V + to peripherals i.e. IR detectors, beams, etc. (Fused at 1 amp) AUX NEG……….Negative to be taken from any negative or common.
  • Page 8 Pi HSC816 Installation Manual - Revision Beta Expander board layout: ZONE 9 ....Zone 1 input EOL resistor 2K7 C ......Common ZONE 10 .... Zone 2 input EOL resistor 2K7 ZONE 11 .... Zone 3 input EOL resistor 2K7 C .......
  • Page 9 Pi HSC816 Installation Manual - Revision Beta Keypad wiring: 4 wire bus line BLACK GREEN YELLOW Door O/P Indications (remote LED) Off = system off. On = system on. Flashing = system alarmed. Keypad LED indications: Bank 1 led indicates zones 1 to 8. Bank 2 led indicates zones 9 to 16 Disarmed state: Zone LED slow flash = Zone bypassed.
  • Page 10 Pi HSC816 Installation Manual - Revision Beta Remote expander layout The remote expander is an 8 zone input and 4 trigger output self contained unit with independent charger and battery. Connection is via the 4 wire bus line and the zone and trigger numbers are link selected.
  • Page 11 Pi HSC816 Installation Manual - Revision Beta BUS LINE CODEX TRANSCEIVER. By using the bus line transceiver, the HSC816 has the capability of accepting up to 16 codex transmitters. Each button could be assigned to any of the keypad functions with encrypted user identification, any keypad emergency condition or any trigger output.
  • Page 12 Pi HSC816 Installation Manual - Revision Beta Defaulting the control panel: 1. Default the control panel by removing all power and placing a jumper across LK1. 2. Apply power (ac volts) to the control panel. 3. After +/- 15 seconds, all leds will return to normal operation. Remove the jumper on LK1.
  • Page 13: Led Indication

    Pi HSC816 Installation Manual - Revision Beta Step 1 – Adding remotes: 1) Enter user programming mode. Select # 6. Ready LED will flash slowly 2) Enter the remote number to be programmed on the keypad 1-8. Key 0 will toggle between Bank 1 and Bank 2 (9 to 16) 3) The remote number LED will flash.
  • Page 14 Pi HSC816 Installation Manual - Revision Beta Bottom row of status LEDs indicate data present in a location. A flashing ready LED indicates that the panel is in a programming mode. Binary values: Zone LED Binary value Status LEDs Home1...
  • Page 15 Pi HSC816 Installation Manual - Revision Beta 24-hour silent - This zone type when activated will cause an instant alarm condition without any siren but with communicator. 24-hour fire - This zone type when activated will cause an instant alarm condition with siren and communicator.
  • Page 16 Pi HSC816 Installation Manual - Revision Beta QUESTION 1 to 16: Location 1 = Zone type Location 2 = Reserved Location 3 = Chime and home types Location 4 = Hardwired / wireless. Location 1 : Zone type Disabled Entry / exit...
  • Page 17 Pi HSC816 Installation Manual - Revision Beta QUESTION 17 to 37: Reserved QUESTION 38: Expander options Select onboard or remote expander Location 1 = Expander options Location 2 = Reserved Location 3 = Reserved Location 4 = Reserved Enable remote...
  • Page 18 Pi HSC816 Installation Manual - Revision Beta QUESTION 45 : Timers Location 1 = Siren timer Location 2 = Siren delay timer Location 3 = Tel line fault timer Location 4 = Ac fail (random time of 1 to 16 minutes + Selection)
  • Page 19 Pi HSC816 Installation Manual - Revision Beta QUESTION 54: Auto test delay Location 1 = Auto test delay Location 2 = Reserved Location 3 = Reserved Location 4 = Reserved Value Delay 1 Day 2 Days 3 Days 4 Days...
  • Page 20: Auto Re-Arm

    Pi HSC816 Installation Manual - Revision Beta QUESTION 59: Arming options Location 1 = Fast arm Location 2 = Fast bypass Location 3 = Arm when faulted Location 4 = Auto re-arm Location 1 Location 2 Value Fast arm Value Fast bypass ...
  • Page 21 Pi HSC816 Installation Manual - Revision Beta QUESTION 65: D ialer options: Location 1 = Reporting formats Location 2 = Dial attempts Location 3 = Ring count Location 4 = Dual reporting. Location 1: Select the desired format required by the monitoring centers base station for landline communications.
  • Page 22 Pi HSC816 Installation Manual - Revision Beta Location 4: Value Dual Reporting  QUESTION 66: Dialer options Location 1 = Enable dialer Location 2 = Reporting delay Location 3:= DTMF Tx level (do not change) Location 4 = DTMF Rx level.(do not change)
  • Page 23 Pi HSC816 Installation Manual - Revision Beta QUESTION 84: Trigger polarity on power up Location 1 = Trigger polarity Location 2 = Reserved Location 3: = Reserved Location 4 = Reserved. Location 1: Select as positive on power-up to give a negative switch on trigger...
  • Page 24 Pi HSC816 Installation Manual - Revision Beta Trigger Event EVENT RESTORE Event 24h Zone 1 Event 24h Zone 2 Event 24h Zone 3 Event 24h Zone 4 Event 24h Zone 5 Event 24h Zone 6 Event 24h Zone 7 Event 24h Zone 8...
  • Page 25 Pi HSC816 Installation Manual - Revision Beta Trigger Event EVENT RESTORE Battery Low Zone Bypass Alarm Any alarm condition Keypad Duress Keypad Medical Keypad Panic Event Keypad Fire Event Zone Tamper Siren On Siren Off Hash Key Event See Question 57 loc 4 = 0...
  • Page 26 Pi HSC816 Installation Manual - Revision Beta Location 4: Trigger action (Wireless triggers) Wireless triggers can only be timed and location 4 must be selected as a zero for a single transmission. If a trigger number is inserted in location 4 this trigger number will transmit once at the end of the trigger timer...
  • Page 27 Pi HSC816 Installation Manual - Revision Beta Q176 L1 to L4 Reporting code Zone 1 Default = 0010 Q177 L1 to L4 Reporting code Zone 2 Default = 0010 Q178 L1 to L4 Reporting code Zone 3 Default = 0010...
  • Page 28 Pi HSC816 Installation Manual - Revision Beta Q283 Codex remote4 Button 1 Button 2 Button 3 Button 4 Q284 Codex remote4 Button 5 Button 6 Button 7 Button 8 Q285 Codex remote4 Button 9 Button 10 Button 11 Button 12...
  • Page 29: Quick Arm

    Pi HSC816 Installation Manual - Revision Beta Q331 Codex remote16 Button 1 Button 2 Button 3 Button 4 Q332 Codex remote16 Button 5 Button 6 Button 7 Button 8 Q333 Codex remote16 Button 9 Button 10 Button 11 Button 12...
  • Page 30 Pi HSC816 Installation Manual - Revision Beta Arm Home (Stay) Key Switch E=Open R=Close Time / Date Inaccurate Bell Trouble Telco Fault E=fail R=restore Battery Test Failure TABLE: B Full Point ID Table (must only be used with new serial TX firmware. Or with teledialer)
  • Page 31: Programming

    Pi HSC816 Installation Manual - Revision Beta 24 Hour Non-Burglary - 150 and 160 24 Hour Non-Burglary Zone Gas Detected Zone Refrigeration Zone Loss Of Heat Zone Water Leakage Zone Foil Break Zone Day Trouble Zone Low Bottled Gas Level Zone...
  • Page 32 Pi HSC816 Installation Manual - Revision Beta Repeater Failure Zone Local Printer Out Of Paper Zone Local Printer Failure Zone Exp. Module DC Loss Zone Exp. Module Low Battery Zone Exp. Module Reset Zone Exp. Module Tamper Zone Exp. Module AC Loss Zone Exp.
  • Page 33 Pi HSC816 Installation Manual - Revision Beta Remote Arm/Disarm User Quick Arm User Keyswitch O/C User Armed STAY User (HOME) Keyswitch Armed STAY User Exception O/C User Early O/C User Late O/C User Failed To Open User Failed To Close User...
  • Page 34 Pi HSC816 Installation Manual - Revision Beta Reversing Relay Disable Zone Notification Appliance Ckt.# 3 Disable Zone Notification Appliance Ckt.# 4 Disable Zone System Peripheral Disables -530 and 540 Module Added Zone Module Removed Zone Communication Disables - 550 and 560...
  • Page 35 Pi HSC816 Installation Manual - Revision Beta Misc - 650 Reserved For Ademco Use Zone Reserved For Ademco Use User Reserved For Ademco Use User System Inactivity Zone Default User Codes: Enter Installer programming level # 3. Press PROG key...
  • Page 36 Pi HSC816 Installation Manual - Revision Beta HSC816 PROGRAMMING WORK SHEET Installer code is changed in question # 000 Question Description Zone type Reserved Home 1 or 2 Hardwired Default Zone 1 1004 Question Description Zone type Reserved Home 1 or 2...
  • Page 37: Error Beep

    Pi HSC816 Installation Manual - Revision Beta Question Description Entry time Reserved Reserved Reserved Default Entry time 5000 Question Description Exit time Reserved Reserved Reserved Default Exit time 5000 Question Description Siren time Siren delay Line fault Ac fail Default...
  • Page 38 Pi HSC816 Installation Manual - Revision Beta Question Description TG 1 to 4 Reserved Reserved Reserved Default Trig polarity 0000 Question Description Condition Reserved Reserved Reserved Default Auto arm 0000 Question Description Hours x 10 Hours x 1 Minutesx10 Minutesx1...
  • Page 39 Pi HSC816 Installation Manual - Revision Beta Question Description Digit 1 Digit 2 Trig num Trig action Default H/W Triggers 0000 Question Description Digit 1 Digit 2 Trig num Trig action Default H/W Triggers 0000 Question Description Digit 1 Digit 2...
  • Page 40 Pi HSC816 Installation Manual - Revision Beta Question Wireless Digit 1 Digit 2 Trig num Trig action Default Triggers 0000 Question Wireless Digit 1 Digit 2 Trig num Trig action Default Triggers 0000 Question Wireless Digit 1 Digit 2 Trig num...
  • Page 41 Pi HSC816 Installation Manual - Revision Beta Question Reporting Full Id d1 Full Id d2 Restricted d1 Restricted d2 Default codes. Z14 0010 Question Reporting Full Id d1 Full Id d2 Restricted d1 Restricted d2 Default codes. Z15 0010 Question...
  • Page 42 Pi HSC816 Installation Manual - Revision Beta Question Rpt Codes Full Id d1 Full Id d2 Restricted d1 Restricted d2 Default KP Medical 0010 Question Rpt Codes Full Id d1 Full Id d2 Restricted d1 Restricted d2 Default Siren Tamp...
  • Page 43 Pi HSC816 Installation Manual - Revision Beta Green Ready LED stops flashes. Repeat for all required users User 1 and 2 master users (all user functions including code changes) Users 3 to 12 are normal users (arm and disarm). Users 3 and 4 can bypass zones.
  • Page 44: Led Indications

    Pi HSC816 Installation Manual - Revision Beta Program Codex remotes: Two separate stages are required to program the Codex remote Step 1 – Learn the remote into the HSC816 Step 2 – Define button functions. Step 1 - Adding remotes Enter programming mode Select #6.
  • Page 45 Pi HSC816 Installation Manual - Revision Beta The zone leds will flash fast to indicate that the zone has triggered Enter a user code to cancel walk test or allow to time out after Sms control functions: These functions are only available if a QD Serial GPRS communicator is connected to the system.