Indicators - Sony VPL-EW295 Operating Instructions Manual

Data projector
Hide thumbs Also See for VPL-EW295:
Table of Contents

Advertisement

B Others

Indicators

The indicators allow checking the status and notify you of abnormal operation of the projector.
If the projector exhibits abnormal status, address the problem in accordance with the table
below.
ON/STANDBY indicator
Status
Lights in red
Flashes in green
Lights in green
Lights in orange
Flashes in red
Flashes twice
Flashes six times
Other number of
flashes
LAMP/COVER indicator
Status
Flashes in red
Flashes twice
Flashes three times The temperature of lamp is unusually high. Turn off the power and
52
Indicators
Meaning/Remedies
The projector is in Standby mode.
• The projector is ready to operate after having been turned on.
• The lamp cools after the projector is turned off.
The projector's power is on.
The projector is in With No Input (Lamp Cutoff). (page 28)
The projector is in abnormal status. Symptoms are indicated by
number of flashes. Address the problem in accordance with the
following. If the symptom is shown again, consult with qualified Sony
personnel.
The internal temperature is unusually high. Check the items below.
• Check if nothing is blocking the ventilation holes. (pages 4, 4)
• Check if the air filter is not clogged. (page 58)
• Check if the Installation Attitude in the Installation menu is set
correctly. (page 30)
Unplug the AC power cord from a wall outlet. After checking that the
ON/STANDBY indicator goes out, plug the power cord to a wall
outlet again then turn on the projector.
Consult with qualified Sony personnel.
Meaning/Remedies
Symptoms are indicated by number of flashes. Address the problem in
accordance with the following.
The lamp cover is not attached securely. (page 56)
wait for lamp to cool then turn on the power again. If the symptom is
shown again, the lamp may be burnt out. In this case, replace the lamp
with a new one (page 56).