INSTRUCTION MANUAL Installation & Operation Induction Cookers MODELS: MI-3.5 CT 7 MI2-7.0 CT COUNTER MODELS MI-3.5 DI & M12-7.0 DI DROP-IN MODELS MI4-14 LEGEND MODELS These instructions should be read thoroughly before attempting installation. Set up and installation should be performed by qualified installation personnel. Keep area around appliances free and clear from combustibles.
IMPORTANT FOR YOUR SAFETY POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPORTANT SHIPPING DAMAGE CLAIM PROCEDURE: For your protection, please note that equipment in this shipment was carefully inspected and packed by skilled personnel before leaving the factory. The transportation company assumed full responsibility for safe delivery upon acceptance of this shipment. IF SHIPMENT ARRIVES DAMAGED: 1.
INTRODUCTION Thank you for purchasing this Montague Induction range. Before operating this unit, read and familiarize yourself with the following operating and safety instructions. SAVE THESE INSTRUCTION FOR FUTURE REFERENCE. WARNING: ELECTRIC SHOCK, FIRE OR BURN INJURIES CAN OCCUR IF THIS EQUIPMENT IS NOT USED PROPERLY...
INSTALLATION & OPERATION PRECAUTIONS Studies have shown that the induction element presents no danger. However, as a precaution for persons using a pacemaker, please keep 12 inches ( 30cm ) from the unit while in operation. The top is made from a strong non-porous material. However, in case of cracking or breakage, ...
Page 7
Unplug when not in use. Never store objects on top of your induction range. Do not use this product for any purpose other than cooking. Unplug and let cool before cleaning and moving. Do not spray controls or outside of unit with liquid or cleaning agents. ...
INSTALLATION This unit is to be used in a level position. Counter top units are designed to be installed on a flat horizontal surface with a minimum clearance of 3” at the rear and 1” at the bottom of the unit. Drop-In units are designed to be installed into an enclosed area with adequate ventilation.
OPERATION 1. Plug power cord into a grounded electrical outlet with the nameplate rated voltage. IMPORTANT! : Using a voltage other than the nameplate rated voltage will cause damage to the unit. WARNING: ELECTRICAL SHOCK HAZARD ! Keep water from entering the inside of the unit. If liquid spills or boils over onto the surface of the unit, Immediately unplug the unit and wipe up any liquid.
Page 10
4. The display will be continuously on displaying the power level when an appropriate pan is placed on the unit. If the unit is running and the power display is flashing, the cooking utensil may not be suitable. WARNING: BURN HAZARD! Induction ranges heat extremely fast.
APPLICABLE COOKWARE The performance of your induction cooking system is enhanced with high quality cookware. All cookware must have a ferrous material bottom, which include: Most Multi-layer Cookware Steel Plated Copper / Bronze Stainless Steel Iron Cast Iron ...
CLEANING To maintain appearance and increase the service life, the induction range top should be cleaned at least daily. 1. Before cleaning, unplug the unit and let it cool completely. WARNING: BURN HAZARD! The top surface gets very hot during cooking. Hot surfaces and hot pans can burn skin.
TROUBLESHOOTING In the event of an error, there will be an error code shown on the display corresponding to the cook surface that has the error. Display Definition Course of Action Change the type of cookware you are using. Refer to the Applicable types of Inadequate load or no load Flashing cookware listed in this manual.
APPENDIX “A” CUT-OUT FOR COUNTER TOP DROP-IN Cut-Out for Countertop Cut-Out for Countertop Drop-In (Single) Drop-In Control Panel (Single) Cut-Out for Countertop Cut-Out for Countertop Drop-In Control Panel (Double) Drop-In (Double)
Page 15
In order to establish full compliance with Proposition 65, we attached a yellow warning label to each gas fired unit manufactured by the Montague Company. Carbon Monoxide would not be present in concentrations that would pose a “significant rist” to the consumer when the equipment is installed, operated and maintained as follows: 1.
Page 16
Serial No. _____________________________________ Model No._____________________________________ Change No.____________________________________ Name & No. of Part Model No. Change No. Serial No. The Montague Company 1830 Stearman Avenue P.O. Box 4954 P/N 32403-5 REV. A 04/12 Hayward, Ca. 94540-4954...