7. After 10 seconds, check of ALARM LED is ON. (When ALARM LED is on, it means
the system has been shutdown as external input signal strength is
too strong. Please refer the Trouble Shooting below and check the system status.)
8. At normal operation, the LED status indicates as below;
ALARM LED OFF/ POWER LED, FWD LEVEL LED ON
Operation Instruction
-Upon confirmation of electric power (100~240V/AC), insert AC cable to power supply,
then using DC cable, insert power cable to DC power input terminal, which is set on the
bottom of the equipment
LED Configuration
-
Power : DC Power is normal -Green LED ON
-
Alarm : FEW,REV over power, When Shut Down- Red LED ON
-
FWD Level : FWD(Down Link) Indicates output Level-Green LED ON/OFF
-
No. of LEDs at ON status
0
1
2
3
4
5
Condition ( Input Signal Level )
Less than -80dBm
-80~-76dBm
-75~-71dBm
-70~-66dBm
-65~-61dBm
-30~-60dBm