FAN STORAGE HEATER RANGE
MODELS: WMF718i - 2.6kW / 18kWh STORAGE & 1.5kW BOOST
WMF724i - 3.4kW / 24kWh STORAGE & 1.5kW BOOST
INSTALLATION
OPERATING
AND
INSTRUCTIONS
IMPORTANT
PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE.
NOTE ALSO THE INFORMATION GIVEN ON THE HEATER
The Installation must be carried out by trained personnel in accordance with Australian wiring rules AS/NZS 3000.
A means for disconnection must be incorporated in the fi xed wiring in accordance with the said rules.
The heater must not be installed immediately below a fi xed socket outlet.
Do not position the heater under windows where curtains can contact the heater casing. Maintain a minimum
distance of 150mm at all times between the heater and combustible materials, such as furniture and curtains.
WARNING in order to avoid overheating, do not cover the heater. Do not place objects in contact with the heater.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
This heater meets AS/NZS 60335 electrical safety requirements. However, any heater type becomes hot in normal
operation. Care must be taken to ensure that prolonged skin contact with the heater does not occur.
WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE
ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction concerning
use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
This appliance is very heavy and must be securely fi xed to a wall. DO NOT UNDER ANY CIRCUMSTANCES
ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.
To maintain stability, it is essential that the heater is placed on a level surface and care should be taken to avoid
irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater.
This heater must be installed where it is impossible for switches and other controls to be touched by a person using
a bath or shower.
IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the fi rst few days of
operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS
WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING
THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS DAMAGE
OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART.

Advertisement

loading

Summary of Contents for Unidare WMF718i

  • Page 1 10452 WMF(i) FAN STORAGE HEATER RANGE MODELS: WMF718i - 2.6kW / 18kWh STORAGE & 1.5kW BOOST WMF724i - 3.4kW / 24kWh STORAGE & 1.5kW BOOST INSTALLATION OPERATING INSTRUCTIONS IMPORTANT PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE. NOTE ALSO THE INFORMATION GIVEN ON THE HEATER The Installation must be carried out by trained personnel in accordance with Australian wiring rules AS/NZS 3000.
  • Page 2: Installation Instructions

    Remove the packing pieces from the slots BOTH SUPPLIES ARE SWITCHED ON AT THE WALL them across the terminal block, marked on the inner front (3 on the WMF718i and 4 Two supplies are required for the “Timer”, having already removed the link on the WMF724i).
  • Page 3 11. Carefully fi t the bottom row of the back relay. This relay will inhibit the operation of the WMF724i and three for the WMF718i. layer of bricks placing the two end bricks into position fi rst. Ensure that the recess the fan during the off peak periods.
  • Page 4: Operating Instructions

    OPERATING INSTRUCTIONS automatically operate at Normal speed when Principles of Operation Control Functions half boost conditions apply. If boost option is selected, the fan will automatically operate at High speed when full Setting the Controls Heat Retention boost conditions apply. The controls are located at the top right hand This storage heater takes in energy when electricity Option 2...