1. General safety information
The use of defective equipment can lead to personal
injury and damage to property (electric shocks, short
circuiting).
Never use defective or damaged equipment. Please contact
our Customer Service department in this event .
Incorrect use leads to an increased risk of injury by
electric shocks or short circuiting.
STOP
Children are not permitted to play with the DuoFern Switch
Adapter Plug.
Danger from fatal electric shock
DuoFern adapter plugs are never fully de-energised. Even
when the DuoFern adapter plug is switched off, the plugged
in electrical appliance is not completely (galvanically) discon-
nected from the mains power supply.
Pull the unit from the socket or DuoFern adapter plug before
undertaking all work on the electrical appliance.
2. Proper use
Proper use
Only use the DuoFern Switch Adapter Plug for connecting and controlling
electrical appliances (e.g. lighting etc.) up to the stated total power level
(Technical Specifications).
Operating conditions
◆ Only operate the DuoFern Switch Adapter Plug in dry rooms.
◆ Only use with 230 V / 50 Hz mains sockets.
◆ The installation and operation of the DuoFern radio system and its
components (e.g. DuoFern Switch Adapter Plug) is only permitted for
those systems and devices where a malfunction in the transmitter or
receiver would not cause a danger to personnel or property or where
this risk is already covered by other safety equipment.
3. Improper use
Never use the DuoFern radio system and its components (e.g. DuoFern Switch
Adapter Plug) for the remote control of devices and systems with height-
ened safety-relevant requirements or where there is a heightened risk of
accidents. This shall require additional safety equipment. Observe the respective
statutory regulations for the installation of such systems.
IMPORTANT
Do not install the DuoFern Switch Adapter plug outside.
4. Brief description
The DuoFern Switch Adapter Plug can be used to integrate and control
one electrical appliance (e.g. lighting) within a DuoFern radio network.
Many of the functions provided by the DuoFern transmitter (e.g.
HomePilot® or DuoFern manual central operating unit) can thereby
be used.
4.1 Function table
DuoFern function
1. Manual operation
2. Unit / light mode
3. Manual mode on / off
4. Automatic timer on / off
5. Random function
6. Automatic dawn function
7. Automatic dawn function on / off
8. Automatic dusk function
9. Automatic dusk function on / off
10. Sun function
11. Automated solar function on / off
12. Connectivity test
13. Connect with radio code
14. Reset via radio (3-stage)
15. Single-button operation
16. Stairwell function
17. Stairway time (impulse duration)
*
The "WR ConfigTool" software can be downloaded from our website www.rademacher.de.
4.2 Functional description
The DuoFern Switch Adapter Plug has two switching modes (unit and light
mode) with which you can control electrical appliances.
You can switch between the two switching modes using the relevant DuoF-
ern transmitter (e.g. HomePilot® etc.). To do so, please read the operating
instructions for the respective DuoFern transmitter.
Factory setting = Unit mode
The following table shows the reactions of the DuoFern Switch
Adapter Plug to the switching commands from a DuoFern trans-
mitter:
Reactions of the DuoFern
Switching commands from
Adapter Plug in:
a DuoFern transmitter*
Unit mode
Light mode
UP
ON
OFF
STOP
OFF
OFF
DOWN
OFF
Automatic dawn function
ON
OFF
Automatic dusk function
OFF
Sun function
OFF
OFF
* e.g. DuoFern standard manual transmitter
DuoFern environmental sensor
DuoFern manual central operating unit
* WR ConfigTool with DuoFern central operating unit
RolloTron Comfort DuoFern / Troll Comfort DuoFern
DuoFern standard manual transmitter
DuoFern wall controller
DuoFern radio transmitter, flush-mounted
Value range
Factory setting
on / off
-
Unit / light mode
Light mode
on / off
Off
on / off
On
-
-
-
-
on / off
Off
-
-
on / off
Off
-
-
on / off
Off
-
-
-
-
-
-
-
-
on / off
Off
100 ms - 3276 s
180 seconds
4.2 Functional description
1
ON
2
3
ON
On-site button for manual control (On/Off) and
1
status LED
Disconnect button
2
Connect button
3
5. Logging DuoFern transmitters on / off
You must assign every required DuoFern transmitter to the DuoFern Switch
HomePilot®
Adapter Plug in order that the DuoFern Switch Adapter Plug can be controlled with
a DuoFern transmitter. You can assign a maximum of 20 DuoFern transmitters
(e.g. HomePilot®; DuoFern manual transmitter standard etc.).
1. Switch the desired DuoFern transmitter to registering mode (please
refer to the corresponding operating instructions).
Registering mode remains active for 60 seconds.
2. Press either the switch 3 Connect (login)" or the switch 2 "Disconnect
(logout)" on the bottom of the DuoFern Switch Adapter Plug.
3. The DuoFern Switch Adapter Plug then transmits either a log-on or
log-off signal.
- The status LED flashes green during login.
- The status LED flashes red during logout.
4. If registration is successful, the status LED will light up constantly green
for approx. 20 seconds.
5. Log the next DuoFern transmitter on / off. In order to do so, repeat steps
1 to 3.
NOTE
The status LED lights up red if the registration process fails, for example
if:
- 20 DuoFern transmitters have already been registered.
- An unsuitable device (e.g. other DuoFern actuator) is registered.
- An attempt was made to log-off a DuoFern transmitter that is not
logged-on.
6. Erase data (Reset)
1. Press and hold the "Disconnect button" 2 until the status LED lights
up constantly red.
2. All of the registered DuoFern transmitters are logged-off.
3. Subsequently, the DuoFern Switch Adapter Plug will be reset to its
original supplied state.
7. Technical Specifications
Supply voltage:
Standby consumption:
Switching capacity:
Protection class:
Frequency:
Dimensions (without plug):
- W x H x D:
230 V / 50 Hz
0.5 W
max. 1300 W
II (only for use in dry areas)
434.5 MHz
64 x 106 x 41 mm

Advertisement