Advertisement

Quick Links

GITLC
User Guide
 Single gang time lag switch
 Replaces a standard light
switch or dimmer
 Suitable for lighting, heating or
ventilation loads
 Turns on for adjustable time period
 Illuminated locating ring
 Switches all lighting, heating and venti-
lation loads up to 10A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GITLC and is the answer not in the manual?

Questions and answers

Summary of Contents for green-i GITLC

  • Page 1 GITLC User Guide  Single gang time lag switch  Replaces a standard light switch or dimmer  Suitable for lighting, heating or ventilation loads  Turns on for adjustable time period  Illuminated locating ring  Switches all lighting, heating and venti-...
  • Page 2 installation This product should be installed in accordance with the current IEE wiring regulations. If in doubt consult a qualified electrician. Compatible with all Use the extender if there is less than 25mm BS4662 dimen- free space. sions back boxes. REMEMBER—put the wires through the ex- Remove top and tender before connecting...
  • Page 3 wiring—2 way switching 2 way switching If more than one time lag switch is required to switch the lighting (e.g. At the top and bot- tom of a staircase) they can be wired in parallel, as in the diagram. LINK com L1 LINK com L1 Locating ring The GITL comes with an LED locating ring which is used to locate the buttons at night.
  • Page 4 Short press—lights on for time period Press for more than 5 seconds to activate (see Activate section). Short press—lights off Press for more than 5 seconds to de-activate (see Activate section).
  • Page 5 setup Remove front cover Time setting (determined by switch, see below) 5 sec—15min 15min—2hour The lights will turn off after the time setting has fin- ished. Clockwise = longer delay. Standard operation Bottom button de-activated. The lights will turn off automatically, but will not turn off manually.
  • Page 6 activate Before using, the unit needs to be activated.  Press and hold the top button for more than 5 seconds.  The red LED will flash to indicate that has activated and the unit will now operate. If the unit is going to be out of use for prolonged peri- ...
  • Page 7 batteries The internal battery should last more than 5 years  When it needs replacing, a red LED will flash on the front of the unit  Follow the steps opposite to replace the battery  Use only good quality, 9V alkaline batteries type PP3 ...
  • Page 8 troubleshooting Lights flicker when off Fan does not stop completely when off Contactor does not open when off Remove the link wire to disable the locating ring—see “wiring” section  ratings Voltage 230VAC +/- 10% Frequency 50Hz Temperature 0ºC to 35ºC Power Compliance BS EN60669-2-1 &...