1-800-253-2991. Information finest materials available and is assembled Fill in the information in the next col- to Roundup’s strict quality standards. This Warnings umn and have it handy when calling for toaster was tested at the factory to ensure Specifications assistance.
IMPORTANT SAFETY WARNINGS The following tips are recommended for maintenance of your stainless steel INFORMATION Be advised of the following warnings when equipment: operating and performing maintenance on Always use soft, damp cloth for Use the following guidelines for safe opera- this unit.
Remove all packing materials and protective Drip Pan coverings from the unit. MS-250: Remove and wash the Wire Trivet, Spatula, Spatula Liner, and Drip Pan (Figure 1) in soap and water. Rinse with clean hot water and allow to air dry.
Electrical Plumbing Turn the water valve on. NOTE: Miracle Steamer models are Hold the Quick Disconnect Insert Place the unit on a sturdy, level table over a bucket, then press and hold designed to use cold tap water. or other work surface. the white plastic tip until there’s a Distilled water may be used to Ensure that the line voltage corre-...
OPERATION NOTE: 208V and 220/240V Miracle Steamers are factory pro- READY LIGHT 1. Turn the power on and allow the grammed for the following unit to preheat for approximately recommended settings: READY 20–30 minutes. • Total Cycle Time (CYC) = 15 min., NOTE: Do NOT push any button during MESSAGE...
NOTE: It is recommended that the SHO and H2O settings be adjusted to the recom- READY READY mended settings shown in the 1500 Programming section of this SINGLE SHOT SINGLE SHOT manual. DOWN PRGM START/STOP DOWN PRGM START/STOP POWER CORD B.
Tighten clamps or re- Finger marks and smears should be place parts if needed. rubbed off using soap and water. MS-250: Remove the Spatula, Hard water spots should be Spatula Liner, Drip Pan, Top Cover, removed using a vinegar solution.
Monthly NOTE: To ensure proper steaming characteristics, some calcium/ The Miracle Steamer utilizes an open mineral deposits must be pres- steam Generator. Water sprayed onto the ent on the Generator surface. If, Generator surface flashes into steam im- during cleaning, the surface does mediately, but the minerals in the water become free of calcium/mineral do not steam, they stay on the Generator...
Page 11
MESH O-RING SCREEN TUBING MALE QUICK DISCONNECT INSERT STRAINER CUP Figure 12. Inlet Hose Assembly Checking and Cleaning the Water Strainer The Water Strainer protects your equipment from any foreign debris in the water line that could get into the food or damage the unit’s solenoid and cause the unit to leak or flood.
TROUBLESHOOTING WARNING To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing. Problem Possible Cause Corrective Action Control Display is blank (power is on but indicator The power cord is not correctly plugged in.
Page 13
Problem Possible Cause Corrective Action Unit heats but there is little or Water Line Valve is closed. Check that the Water Line Valve is open. no steam produced Filter Strainer is restricted. Check and clean the Filter Strainer as described in the Maintenance section of this manual.
WIRING DIAGRAM *NOTE: For 208-240 VAC units, the two primary coils are wired in series with one another. For 120 VAC units, the two primary coils are wired in parallel with one another. P/N 1010455 Rev. E 01/15...
(100 miles/160 km) round trip from the nearest authorized service agency. Roundup reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.