  • Page 1 Miracle Steamer Model MS-250/255 owner’s manual Manufacturing Numbers: 9100430, 9100435, 9100436, 9100437, 9100438, 9100440, 9100460, 9100462, 9100466, & 9100468 www.ajantunes.com P/N 1010455 Rev. E 01/15...
  • Page 2: Table Of Contents

    1-800-253-2991. Information finest materials available and is assembled Fill in the information in the next col- to Roundup’s strict quality standards. This Warnings umn and have it handy when calling for toaster was tested at the factory to ensure Specifications assistance.
  • Page 3: Warnings

    IMPORTANT SAFETY WARNINGS The following tips are recommended for maintenance of your stainless steel INFORMATION Be advised of the following warnings when equipment: operating and performing maintenance on Always use soft, damp cloth for Use the following guidelines for safe opera- this unit.
  • Page 4: Specifications

    (435 MM) (527 MM) 9-1/2” (234 MM) Electrical Ratings Model & Plug Volts Watts Amps Hertz Mfg. No. Description MS-250 6-20P, 20 Amp., 250 VAC, 3300 15.9 50/60 9100430 Non Locking MS-250 6-20P, 20 Amp., 250 VAC, 3300 15.9 50/60 9100435...
  • Page 5: Installation

    Remove all packing materials and protective Drip Pan coverings from the unit. MS-250: Remove and wash the Wire Trivet, Spatula, Spatula Liner, and Drip Pan (Figure 1) in soap and water. Rinse with clean hot water and allow to air dry.
  • Page 6: Electrical

    Electrical Plumbing Turn the water valve on. NOTE: Miracle Steamer models are Hold the Quick Disconnect Insert Place the unit on a sturdy, level table over a bucket, then press and hold designed to use cold tap water. or other work surface. the white plastic tip until there’s a Distilled water may be used to Ensure that the line voltage corre-...
  • Page 7: Operation

    OPERATION NOTE: 208V and 220/240V Miracle Steamers are factory pro- READY LIGHT 1. Turn the power on and allow the grammed for the following unit to preheat for approximately recommended settings: READY 20–30 minutes. • Total Cycle Time (CYC) = 15 min., NOTE: Do NOT push any button during MESSAGE...
  • Page 8: Hi-Limit Reset Button

    NOTE: It is recommended that the SHO and H2O settings be adjusted to the recom- READY READY mended settings shown in the 1500 Programming section of this SINGLE SHOT SINGLE SHOT manual. DOWN PRGM START/STOP DOWN PRGM START/STOP POWER CORD B.
  • Page 9: Maintenance

    Tighten clamps or re- Finger marks and smears should be place parts if needed. rubbed off using soap and water. MS-250: Remove the Spatula, Hard water spots should be Spatula Liner, Drip Pan, Top Cover, removed using a vinegar solution.
  • Page 10: Monthly

    Monthly NOTE: To ensure proper steaming characteristics, some calcium/ The Miracle Steamer utilizes an open mineral deposits must be pres- steam Generator. Water sprayed onto the ent on the Generator surface. If, Generator surface flashes into steam im- during cleaning, the surface does mediately, but the minerals in the water become free of calcium/mineral do not steam, they stay on the Generator...
  • Page 11 MESH O-RING SCREEN TUBING MALE QUICK DISCONNECT INSERT STRAINER CUP Figure 12. Inlet Hose Assembly Checking and Cleaning the Water Strainer The Water Strainer protects your equipment from any foreign debris in the water line that could get into the food or damage the unit’s solenoid and cause the unit to leak or flood.
  • Page 12: Troubleshooting

    TROUBLESHOOTING WARNING To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing. Problem Possible Cause Corrective Action Control Display is blank (power is on but indicator The power cord is not correctly plugged in.
  • Page 13 Problem Possible Cause Corrective Action Unit heats but there is little or Water Line Valve is closed. Check that the Water Line Valve is open. no steam produced Filter Strainer is restricted. Check and clean the Filter Strainer as described in the Maintenance section of this manual.
  • Page 14: Replacement Parts

    REPLACEMENT PARTS P/N 1010455 Rev. E 01/15...
  • Page 15 P/N 1010455 Rev. E 01/15...
  • Page 16 #8-32 x 1/2” (one-way) 94b 210K123 4” Leg Kit (optional) (not shown) 0300129 Stud, Cover Hold Down 308P143* Nut, Hex, KEPS, #8-32 0800359 Trivet, Spatula (MS-250 only) 040P138* Locknut, 1/2” 310P136* Screw, Machine, 7000138 Quick Disconnect Female Kit 040K251 Strain Relief (Incl. #12) #10-32 x 1-1/4”...
  • Page 17 Dual Water Pressure Regulator Kit - Part No. 7000235 Item Part No. Description Qty. TO STEAMER 7000139 Elbow, Quick Disconnect - 1/4” TO STEAMER 2030126 Tubing 1/4” I.D. PVC BRD. 24” Long 2030125 Tubing 1/4” I.D. PVC BRD. 12” Long 2040150 Elbow, Male - Nylon 1/4”...
  • Page 18: Wiring Diagram

    WIRING DIAGRAM *NOTE: For 208-240 VAC units, the two primary coils are wired in series with one another. For 120 VAC units, the two primary coils are wired in parallel with one another. P/N 1010455 Rev. E 01/15...
  • Page 19: Notes

    NOTES P/N 1010455 Rev. E 01/15...
  • Page 20: Limited Warranty

    (100 miles/160 km) round trip from the nearest authorized service agency. Roundup reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.