13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance. ADVICE www. .co.il e-mail:advice@advice. co.il...
Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner. Figure 1 Hybrid Power System ADVICE www. .co.il e-mail:advice@advice.
7. AC input 8. AC output 9. PV input 10. Battery input 11. Circuit breaker 12. RS232 communication port 13. Parallel communication cable (only for parallel model) 14. Current sharing cable (only for parallel model) ADVICE www. .co.il e-mail:advice@advice. co.il...
Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires. SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY. ADVICE www. .co.il e-mail:advice@advice. co.il...
To reduce risk of injury, please use the proper recommended cable size as below. Suggested cable requirement for AC wires Model Gauge Torque Value 1KVA 16 AWG 0.5~ 0.6 Nm 2KVA 14 AWG 0.8~ 1.0 Nm 3KVA 12 AWG 1.2~ 1.6 Nm ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 9
Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner. ADVICE www. .co.il e-mail:advice@advice.
Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector. 3. Make sure the wires are securely connected. ADVICE www. .co.il e-mail:advice@advice.
Please use supplied communication cable to connect to inverter and PC. Insert bundled CD into a computer and follow on-screen instruction to install the monitoring software. For the detailed software operation, please check user manual of software inside of CD. ADVICE www. .co.il e-mail:advice@advice.
Warning condition occurs in the inverter. Function Keys Function Key Description To exit setting mode To go to previous selection DOWN To go to next selection ENTER To confirm the selection in setting mode or enter setting mode ADVICE www. .co.il e-mail:advice@advice. co.il...
Constant two bars will flash in turns. Voltage mode Bottom three bars will be on and the top > 2.167 V/cell bar will flash. Floating mode. Batteries are fully charged. 4 bars will be on. ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 14
Indicates unit connects to the PV panel. Indicates load is supplied by utility power. Indicates the utility charger circuit is working. Indicates the DC/AC inverter circuit is working. Mute Operation Indicates unit alarm is disabled. ADVICE www. .co.il e-mail:advice@advice. co.il...
Available options in 2-3KVA 24V models: chargers. 30A (default) (Max. charging current = utility charging current + solar charging current) Available options in 2-3KVA 24V/48V Plus and 4-5KVA 48V models: ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 16
Restart enable (default) Auto restart when over temperature occurs 50Hz (default) 60Hz Output frequency Available options in 1KVA 24V model: 20A(default): Maximum utility charging current Available options in 2-3KVA 24V and 2-3KVA 24V Plus models: ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 17
Available options in 24V models: 22.0V 22.5V 23.0V (default) 23.5V 24.0V 24.5V 25.0V 25.5V Setting voltage point back to utility source when selecting “SBU priority” in program 01. Available options in 48V models: 46V (default) ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 18
Beeps while primary source is interrupted Bypass disable Bypass enable Overload bypass: (default) When enabled, the unit will transfer to line mode if overload occurs in battery mode. Record enable Record disable (default) Record Fault code ADVICE www. .co.il e-mail:advice@advice. co.il...
PV voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, main CPU Version and second CPU Version. Selectable information LCD display Input Voltage=230V, output voltage=230V Input voltage/Output voltage (Default Display Screen) Input frequency=50Hz, Output frequency=50Hz Input frequency/Output frequency ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 20
When connected load is lower than 1kVA, load in VA will present xxxVA like below chart. Input voltage/Load in VA When load is larger than 1kVA (≧1KVA), load in VA will present x.xkVA like below chart. ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 21
Input voltage/Load in Watt When load is larger than 1kW (≧1KW), load in W will present x.xkW like below chart. Main CPU version 00014.04 Main CPU version checking Secondary CPU version 00003.03 Secondary CPU version checking ADVICE www. .co.il e-mail:advice@advice. co.il...
No charging. temperature, output short circuited and so on. Utility can power loads when Power from utility the unit starts up without battery. (Only available in 4K/5K model with single operation) ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 23
Line Mode Charging by utility. also charge the battery at line mode. Power from battery and PV energy. The unit will provide output Battery Mode power from battery and PV power. Power from battery only. ADVICE www. .co.il e-mail:advice@advice. co.il...
Over DC voltage in AC output Battery connection is open Current sensor failed Output voltage is too low NOTE: Fault codes 51, 52, 53, 55, 56, 57 and 58 are only available in 4K/5K model. ADVICE www. .co.il e-mail:advice@advice. co.il...
Overload Beep once every 0.5 second Output power derating Beep twice every 3 seconds Solar charger stops due to low battery. Solar charger stops due to high PV voltage. Solar charger stops due to overload. ADVICE www. .co.il e-mail:advice@advice. co.il...
>95% ( Rated R load, battery full charged ) 10ms typical (UPS); Transfer Time 20ms typical (Appliances) Output Power Rated Power Output power derating: When AC input voltage drops to 170V, the output power will be derated. 50% Power 170V 280V Input Voltage ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 27
@ 20% ≤ load < 50% 20.4Vdc 40.8Vdc @ load ≥ 50% 19.2Vdc 38.4Vdc High DC Recovery Voltage 29Vdc 58Vdc 62Vdc High DC Cut-off Voltage 31Vdc No Load Power Consumption <25W <50W Saving Mode Power Consumption <10W <15W ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 28
75Vdc max 102Vdc max 145Vdc PV Array MPPT Voltage Range 30~66Vdc 60~88Vdc 60~115Vdc Min battery voltage for PV charge 17Vdc 34Vdc 34Vdc Standby Power Consumption Battery Voltage Accuracy +/-0.3% PV Voltage Accuracy +/-2V Charging Algorithm 3-Step ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 29
3KVA 48V Plus Safety Certification Operating Temperature 0°C to 55°C Range Storage temperature -15°C~ 60°C Dimension (D*W*H), mm 128 x 272 x 355 140 x 295 x 479 140 x295 x540 Net Weight, kg 11.5 12.5 13.5 ADVICE www. .co.il e-mail:advice@advice. co.il...
Fault code 55 Output voltage is unbalanced. If the battery is connected Battery is not connected well or Fault code 56 well, please return to repair fuse is burnt. center. ADVICE www. .co.il e-mail:advice@advice. co.il...
Page 32
1500 2000 2500 5KVA 3000 3500 4000 4500 5000 Note: Backup time depends on the quality of the battery, age of battery and type of battery. Specifications of batteries may vary depending on different manufacturers. ADVICE www. .co.il e-mail:advice@advice. co.il...