  • Page 1: Installation Manual

    Integral Evacuated Tube Solar Water Heater ENGLISH Version 1.8 Model: GSE IP-195 INSTALLATION MANUAL Models: IP-195 (2009122A) And IP-195G (2009122B) RENEWABLE ENERGY GLOBAL INC. http://www.renewableenergyglobal.com...
  • Page 2: Table Of Contents

    13. The Plumbing Parts ........................17 14. Plumbing Diagram ........................18 15. Plumbing Connections ........................19 16. System Configuration ........................21 17. Part List ............................22 18. Specifications ..........................23 19. Company Office Addresses ......................24 INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 3: Important Notices

    TR-71Ui Temprature Bath & Shower Monitor powered by battery (T1) Serial Number Existing Hot Water Heater Date Installer Name (Signature) Renewable energy Inc. Company 6 Cornell Lane Little Neck, NY 11363 USA Service Phone INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 4: Product Description

    General system Information Model GSE IP-195 is a domestic solar water heater system designed by Globe Solar Energy Inc. a parent company of the Renewable Energy Inc.. The system meets with the requirements of the different climates , the plumbing codes in various areas in the North America and the solar domestic hot water systems standards, such as CSA-F379 and CSA- F383.
  • Page 5: Specific Notices

    Please contact to the installer to order the parts and do the replacement. The battery of the temperature monitor needs to be replaced when the battery is out. The battery can be purchased at store. INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 6: Warranty

    SOLAR WATER HEATING SYSTEMS (Version: June 2008) system Illustration Tank Surface Appearance Insulation T&P Valve Tube Ring Pressurized Inner Tank Heat Pipe and Aluminium Circle Hot Water Outlet Vocuum Tube Cold Water Inlet Frame Leg Pad Reflector End Bracket INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 7: Open Box Inspections

    Box 5: Heat Pipe Box Heat Pipes (24 Pieces) Reflectors (4 Pieces) End Brackets Bar(1 Piece) Water Tank (1 Unit) Box 1: Tank Box Contents Heat Pipes (24 Pieces in one box) Box 5: Heat Pipe Box Contents INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 8 Valve Labels on the back of the valve Tags Tube Rings Valve Tags Lock Bolts Heat Pipe Seal Rings Tank Shoulder Rests Bolts and Nuts Leg Pads Box 4: Frame Box and Accessary Contents INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 9: Valve Labels

    VAlVe lABels Valve List and Labels INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 10 Valve lables - 2 INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 11: Components Description

    CoMPonenT desCRIPTIons 3. Components description GSE IP-195 contains 24 evacuated glass tubes, which has an aluminum fin and a heat pipe in the middle. The unique design optimizes the heat absorbing and transfer efficiency. The system has five components illustrated as below.
  • Page 12: Assembling Frame

    Lift the frame to the system mounting location Mount the leg pads to the roof mounting system attached to the roof beams Cross enforce bars (2 pairs) Reflectors (4 pieces) End Caps (24 pieces) Flat Roof Frame INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 13 Aluminum Fins (24 Pieces) Fast Tank Bolts (4 Pieces) Tube Rubber Rings (24 Pieces) Electric Grounding Hole Evacuated Tubes (24 Pieces) Leg Pads (6 Pieces) End Caps (24 Pieces) Flat Roof System - Side Elevation INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 14: Assembling

    Tight the bolt until the leakage stops in any holes with leakage observed. Put the Tube Rubber Ring in the tank holes and insert the glass tubes and secure them by assembling the tube rubber rings and plastic end caps. INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 15: Pitched Roof And Footprint Dimensions

    Joist point where a foot pad rests shall be on top of a strut. If not, additional structure should be added. Reenforce Struts Reenforce Struts INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 16: Roof Mounting Details

    2 x 6” Preserved Wood Leg pad 2 x 4” Preserved Wood Typical Mounting Details 11. Grounding Aluminium Leg Cold Water Pipe Star Washers Ground Pad Bolt Ground Wire Ground Wire Grounding Details (Outside) Grounding Details (Inside) INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 17: Roof Load Distributions

    Leg Pad Placement with OC 16” 1 1/8” 7/8” 1” Sealant Leg Pad Ø1/8” Ø1/8” Shingle Wood Joist Ø1/8” Ø1/8” 1/2” Corrosion Resistant Deck Screw 3” 3” Material: Powder Coated Steel. Leg Pad Side View of Leg Mounting Placement INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 18: The Plumbing Parts

    Brass Ball Valve Thermostat 3/4” CxCxC Tee and 3/4” x 1/2” Copper x Female 3/4” Copper x Female Adapter 3/4” Type L Copper Water Couplings Adapter (2 Pieces) Tubing according ASTM B88 INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 19: Plumbing Diagram

    14. Plumbing diagram GSE IP-195 is a solar thermal hot water heater system which pre-heats city water with solar energy prior to feeding to the conventional hot water heater. It can be integrated with the existing gas, electricity, propane or oil hot water heater by installing at the upstream of the existing hot water heater.
  • Page 20: Plumbing Connections

    It will then be up to the local code to dictate exactly how this is done. INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 21 A reference diagram of installation is shown below. Hot Water Pipe Cold Water Pipe Inner Pipe Insulations 1/2” Outer Pipe Insulations 2” 4” PVCpipe Pipe Insulation for external wall mounting INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 22: System Configuration

    Bypass Valve Normal operation Position: OFF V2, V3: solar Isolation Valve Normal Operation Position: ON Existing Hot Water Heater V4, V5: solar drain Valve Normal Operation Position: OFF Mixing Valve Set temperature 145.4°F or lower INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 23: Part List

    Bolts and nuts Ø 6 x 25 mm IP-195-048 Lock Bolt IP-195-049 Valve Label V1,V2,V3,V4,V5 IP-195-050 Grand Cable * One GSE IP-195 contains either flat roof parts or pitched roof parts. PART NUMBER PART NAME Q’ty PART NUMBER PART NAME Q’ty IP-195-061** Ball Valve 3/4”...
  • Page 24: Specifications

    Flat plate diffuse, aluminum Frame Aluminum Alloy Daily Efficiency >55% ( >42% in winters) Dimensions 6’8” x 4’9” x 5’3” (W x D x H, for flat roofs) System Operation Climate -30°F to 122°F INSTALLATION MANUAL FOR MODEL: GSE IP-195...
  • Page 25: Company Office Addresses

    Renewable Energy Inc., including but not limited to: Transmission by any method; storage in any medium, system or program; display in any form performance; hire, lease, rental or loan. INSTALLATION MANUAL FOR MODEL: GSE IP-195...

This manual is also suitable for:

Gse ip-195g2009122a2009122b

Table of Contents