loading

Summary of Contents for Idylis 526011

  • Page 1 ITEM #0526011 ITEM #0526051 DEHUMIDIFIER Idylis® is a registered trademark of LF, LLC. All Rights Reserved. Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number__________ Purchase Date__________ Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday, 8 a.m. - 6 p.m., EST, Friday, 8 a.m.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PACKAGE CONTENTS ……………………………………………………………………..3 SAFETY INFORMATION…………………………………………………………....4 OPERATING INSTRUCTIONS……………………………………………………………..7 CARE AND MAINTENANCE……………………………………………......11 TROUBLESHOOTING……………………………………………........11 WARRANTY……………………………………………………………....………..12 REPLACEMENT PARTS LIST…………………………………………....…..13 (Item #0526051 only) (Item #0526051 only) PART DESCRIPTION QUANTITY Control Panel Air Vent Drain Bucket Handle Air Intake Air Filter Continuous Drain Outlet Drain Connector (Item #0526051 only) Castors Drain Tube (Item #0526051 only)
  • Page 3 SAFETY INFORMATION SAFETY INFORMATION 1. DO NOT pull on the power cord to avoid Please read and understand this entire manual before attempting to assemble, operate or install breakage, potential danger, or injury. the product. • Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit.
  • Page 4: Safety Information

    SAFETY INFORMATION OPERATING INSTRUCTIONS 5. DO NOT drop anything into the machine. Features of the Control Panel: 6. Close all windows to allow for the maximum possible efficiency or removal of moisture. 1) POWER Button: On / Off 2) FAN SPEED Button: High / Medium / Low 3) TIMER: Auto turn on / Auto turn off 4) TIMER / HUMIDITY Set 5) Filter Timer...
  • Page 5 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS START OPERATION DEFROST Fig. 1 1. Place the product in an upright position on a flat, stable, and When the machine is operated at low temperatures (less than 64.4°F), the surface of the heat-resistant surface. Make sure there is nothing flammable or evaporator may accumulate a layer of frost which would reduce the efficiency of the machine.
  • Page 6: Care And Maintenance

    OPERATING INSTRUCTIONS CARE AND MAINTENANCE INSTALLING PVC DRAIN HOSE CLEANING When the water tank is full and/or incorrectly positioned inside the cabinet, the water full red light CAUTION: Before attempting to clean and/or service this unit, always disconnect the power turns on and remains on until such time that the tank is emptied and/or correctly re-positioned.
  • Page 7: Warranty

    8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance Printed in China outdoors that is not approved for outdoor application). Idylis® is a registered trademark Proof of purchase date will be required for warranty claims; so, please retain bills of sale. of LF, LLC. All Rights Reserved.
  • Page 8 ARTÍCULO #0526011 ARTÍCULO #0526051 DESHUMIDIFICADOR Idylis® es una marca registrada de LF, LLC. Todos los derechos reservados. ADJUNTE SU RECIBO AQUÍ Número de serie __________ Fecha de compra__________ ¿Preguntas, problemas, piezas faltantes? Antes de volver a la tienda, llame a nuestro Departamento de Servicio al Cliente al 1-800-643-0067, de lunes a jueves de 8 a.m.
  • Page 10 20 cm 20 cm...
  • Page 11: Características Del Panel De Control

    Cuando la unidad esté en espera, presione el botón del TEMPORIZADOR para configurar el encendido automático de la máquina. Presione los botones "+" o "-" para seleccionar un tiempo específico.
  • Page 12 INSTRUCCIONES DE FUNCIONAMIENTO INSTRUCCIONES DE FUNCIONAMIENTO INICIO DEL FUNCIONAMIENTO DESCONGELACIÓN Fig. 1 1. Coloque el producto en posición vertical sobre una superficie plana, Cuando la máquina funciona a temperaturas bajas (menos de 18 °C o 64,4 °F), la superficie del nivelada y resistente al calor. Asegúrese de que no haya nada inflamable evaporador puede acumular una capa de escarcha que reduciría la eficacia de la máquina. o sensible al calor en un radio de 99,06 cm. El f uncionamiento del Cuando esto ocurra, la máquina entrará en modo de descongelamiento periódico. La máquina producto en cualquier otra posición podría ser peligroso.
  • Page 13 INSTRUCCIONES DE FUNCIONAMIENTO CUIDADO Y MANTENIMIENTO INSTALACIÓN DE LA MANGUERA DE DESAGÜE DE PVC LIMPIEZA Cuando el tanque de agua está lleno y/o en posición incorrecta dentro del gabinete, la luz roja indicadora de PRECAUCIÓN: Antes de intentar limpiar y/o realizar mantenimiento a esta unidad, siempre desconecte tanque lleno de agua se enciende y permanece encendida hasta el momento en que el tanque se vacía y/o el cable del suministro de electricidad del tomacorriente. reubica correctamente. Esta condición tendrá como resultado el apagado inmediato del sistema de deshumidificación (el compresor 1) NO use gasolina, benceno, disolvente de pintura ni cualquier otro químico para limpiar esta unidad, y el motor del ventilador dejan de funcionar). Esta es una característica de seguridad. Cuando el tanque de agua ya que estas sustancias dañarán o deformarán los componentes plásticos y el brillo del acabado.
  • Page 14 D5401-870-A-C7 Ruedecillas D7402-100 D7402-100 Tapa suave D7324-030 D7324-030 Enchufe D7306-160-A-A5 D7306-160-A-C7 Filtro de aire D7301-540-A-A5 D7301-540-A-C7 Rejilla de entrada D4255-210-A-A5 D4255-210-A-C7 Tubo de desagüe VB015PF5.5-5000 Impreso en China Idylis® es una marca registrada de LF, LLC. Todos los derechos reservados.