Summary of Contents for DNF Controls 4000CL-LPH

  • Page 1 12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. 4000CL-LPH 400 CLIP FAST ACCESS SYSTEM Louth Protocol - Philips Recue USER MANUAL 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 2: Table Of Contents

    LOAD AND PLAY A LOOPED CLIP CREATE NEW CLIPS RECORDING CLIPS TRANSFERRING CUELIST TRANSMIT CUE LIST FUNCTION RECEIVE CUE LIST FUNCTION MENU OPTIONS FUNCTION TABLE SPECIFICATIONS DNF CONTROLS LIMITED WARRANTY Manual Version..………........2.5 080604 Document No..……....4000CL-LPH_User_Manual 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 3: Revision History

    The ST300-S/SM is referred to as “ST300”. Words surrounded by brackets, for example, [ENTER], are keys on the ST300. [XXX] + [XXX] means hold the two keys down simultaneously. XXX = Key name. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 4: System Installation

    Press [ESC] at any time to exit. Check the other options in the SETUP MENU prior to using the ST300 to confirm proper Record mode, and other User settable modes. Installation is complete. Connection Diagram 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 5: Video Server Setup

    The contents of the selected Cue Point are shown on the bottom line of the display. Press [LOAD] to load the CLIP ID shown on the bottom line of the display. Press [PLAY] to play the clip. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 6: Recue The Currently Loaded Clip

    VIEW THE CLIP ID OF THE CURRENTLY LOADED CLIP On the ST300 Press and hold the [SHIFT] key. Press and release the [LOAD] key. The bottom line will show: “Loaded Clip: xxxxxxxx” where xxxxxxxx is the CLIP ID. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 7: Loop A Clip

    Select the desired SHOTLIST location by pressing [NEXT CUE], [LAST CUE] or manually entering the 1-, 2- or 3-digit location number Press [LOAD] to load the desired Clip. Press [PLAY]. The CLIP will continually loop until [STOP] is pressed. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 8: Create New Clips

    Press [LOAD] or [ENTER] to create the selected CLIP ID. If the selected CLIP ID already exists, a warning message will be displayed. To load the existing clip, press [ENTER]. Press [ESC] to exit without loading the existing clip. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 9: Recording Clips

    Press [CLIP LIST] and then [ENTER] to manually enter the new CLIP ID. Press [ENTER] or [LOAD] to create the new clip. Press [RECORD] to start recording. Press [STOP] to stop recording. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 10: Transferring Cuelist

    The TRANSMIT CUELIST function allows you to transmit your list of Cue Points to a PC, using the provided utility software on the PC, or to another ST300. Transfer to a PC requires OpSuite 3.0 software, which runs on a Windows-based computer. Contact DNF Controls for more information.
  • Page 11: Receive Cue List Function

    The RECEIVE CUELIST function allows you to receive your list of Cue Points from a PC or from another ST300. Transfer to a PC requires OpSuite 3.0 software, which runs on a Windows-based computer. Contact DNF Controls for more information. To Receive Cue Points from the ST300...
  • Page 12: Menu Options

    CLEAR Press [DEL] to clear all Cue Point locations to 00:00:00:00. MEMORY DISPLAY The version number for the currently installed software is displayed. SOFTWARE VERSION RECORD= [RECORD] or [RECORD] + [PLAY] 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 13 Select Louth Port numbers 1-9 for VTR 1-4 for Playout Channels. PORT At least one VTR must be assigned a Port Number. To turn the Port off, choose 00. Set maximum record length. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 14: Function Table

    Press again to put VTR into STOP mode. TIME MODE [TIME MODE] Press to toggle between Timecode (TC), VITC (VT) or Tape Timer SELECT (TM) display modes. RECUE [RECUE] Press to Recue the loaded clip. 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 15: Specifications

    Receive B Transmit B Transmit A Transmit Common Frame Ground Spare POWER CONNECTOR 9-Pin D-Type, Male Pin # +5v DC +5 VDC +5v DC Ground Ground Ground +12 VDC Ground –12 VDC 4000CL-LPH, 400 Clip Fast Access System, Louth Phillips Protocol...
  • Page 16: Dnf Controls Limited Warranty

    13. DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one (1) year from the date of sale to the original purchaser from DNF Controls. In order to enforce the rights under this warranty, the customer must first contact DNF’s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair.