Smoke & carbon monoxide alarm with silence control

Advertisement

MODEL USI-7795
SMOKE & CARBON MONOXIDE ALARM
WITH SILENCE CONTROL
The smoke alarm uses an extremely small amount of a radioactive element in the ionization
chamber. Do not tamper with radioactive sealed source or try to repair the smoke alarm
yourself. Refer to instructions for repairs.
LIMITATIONS AND FUNCTIONS
• This combination smoke/carbon monoxide (CO) alarm requires constant 120VAC power AND
a working 9 Volt battery to operate properly.
• THERE ARE TWO BASIC SMOKE ALARM TYPES - IONIZATION AND PHOTOELECTRIC.
Ionization smoke alarms (such as this smoke alarm) are your best overall choice for reliability
and fast response time, since they quickly sense small "invisible" smoke particles and will
also sense larger "visible" smoke particles. Photoelectric smoke alarms may respond more
quickly in certain types of fires, for example - slow smoldering fires with large "visible" smoke
particles. ALL TYPES OF SMOKE ALARMS HAVE LIMITATIONS. NO TYPE OF SMOKE
ALARM CAN SENSE EVERY KIND OF FIRE OR SMOKE EVERY TIME.
• SMOKE ALARMS can sound an alarm only when smoke reaches their sensors. Smoke may
not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape. They do not sense
heat, flame or gas (propane).
• ALL alarms have limitations. This combination smoke/CO alarm is not foolproof and is not
warranted to protect lives or property. It is not a substitute for insurance.
• WARNING - SINCE A SMOKE OR CO ALARM WILL NOT WORK WITHOUT POWER, having an
alarm(s) that works from two completely different power sources, such as an AC direct wire with
battery backup can give you an extra measure of protection in case of an AC power failure or a dead
battery.
• CO ALARMS are designed to detect carbon monoxide gas from any source of combustion
that reaches their sensor. They are NOT designed to detect any other type of gas.
• USING A SMOKE ALARM IN A SMOKY AREA LIKE A KITCHEN, OR IN A HIGH HUMIDITY
AREA NEAR A SHOWER, CAN CAUSE FALSE ALARMS. DO NOT TURN OFF THE AC
POWER TO QUIET THE ALARM. A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT
IS NOT POWERED. Properly locate your alarm to avoid nuisance alarms.
• A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY
CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED, VIOLENT
EXPLOSIONS, ESCAPING GAS, IMPROPER STORAGE OF FLAMMABLE MATERIALS,
OVERLOADED ELECTRICAL CIRCUITS, CHILDREN PLAYING WITH MATCHES, NATURAL
CAUSES SUCH AS LIGHTNING, OR ARSON. FIRE PREVENTION IS YOUR BEST
SAFEGUARD.
• SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM.
Smoke from fires may not reach the sensing chamber and set off the alarm. One unit should
be installed inside each bedroom or sleeping area.
• SMOKE ALARMS MAY NOT DETECT FIRE ON ANOTHER FLOOR OR AREA OF THE
HOME. Recommended minimum protection is at least one unit in every sleeping area and
every bedroom on every level of your home. Interconnected units may provide earlier warning
than stand-alone units since all units alarm when one detects smoke.
• ALARMS MAY NOT BE HEARD. The alarm horn in this unit meets or exceeds current
standards, but it may not be heard if: (1) the unit is located outside a closed or partially closed
door; (2) residents recently consumed alcohol or drugs; (3) the alarm is drowned out by noise
from stereos, TV's, air conditioners or other appliances or (4) if residents are hearing impaired
or sound sleepers.
• Because it is possible for the alarm to fail at any time, you must test the alarm weekly and
replace it every 5 years.
READ ALL INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USI-7795 and is the answer not in the manual?

Questions and answers

Summary of Contents for usi USI-7795

  • Page 1 MODEL USI-7795 SMOKE & CARBON MONOXIDE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber. Do not tamper with radioactive sealed source or try to repair the smoke alarm yourself.
  • Page 2: If The Co Alarm Sounds

    IMPORTANT SAFETY INFORMATION WHAT YOU SHOULD KNOW ABOUT CARBON MONOXIDE (CO) MILD EXPOSURE MEDIUM EXPOSURE EXTREME EXPOSURE WHAT YOU SHOULD DO IF THE CO ALARM SOUNDS...
  • Page 3: If The Smoke Alarm Sounds

    WHAT YOU SHOULD DO IF THE SMOKE ALARM SOUNDS YOU MUST QUICKLY DO THE FOLLOWING: If the smoke alarm sounds and you have not pushed the test button, it is a warning of a dangerous situation. Your immediate response is necessary. To prepare for such occurrences, develop family escape plans, discuss them with ALL household members and practice them regularly.
  • Page 4: Installing Combination Smoke/Co-Alarm For Residential Use

    INSTALLING THE COMBINATION SMOKE/CO ALARM FOR RESIDENTIAL USE...
  • Page 5: Avoid These Locations

    Mobile Home Installation: For minimum protection, smoke alarms should be installed in compliance with H.U.D. Manufactured Home Construction Safety Standards, Title 24 CFR, Section 3280.208 and Section 3282. For additional protection, see Single Story Residence smoke alarm requirements/recommendations for Existing Homes and New Construction Homes.
  • Page 6: Installation And Operation

    THIS COMBINATION SMOKE/CO ALARM WILL NOT WORK WITHOUT 120 VAC POWER AND A GOOD BATTERY PROPERLY INSTALLED. THE ALARM SHOULD BE TESTED WHEN INSTALLED AND THEN TESTED WEEKLY AFTER THAT. INSTALLATION AND OPERATION INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY. CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE! •...
  • Page 7 This combination alarm may be interconnected with as many as 11 other USI ELECTRIC model smoke alarms such as USI-1103, USI-1203, USI-1204, USI-1209, USI-1213, USI-2204, USI-3204, USI-5204 and 6 other units which may be a...
  • Page 8: Operation, Testing & Maintenance

    To activate 9 volt battery and alarm, hold battery drawer closed, pull and remove the PULL-TAB. Discard PULL-TAB. See "TAMPER LOCKING PIN." Turn on AC power and press the TEST/RESET button. Check the LED's for proper operation (see "TESTING YOUR ALARM"). After test sequence, the Green LED lights to indicate AC power and blinks off approximately every 20 seconds to indicate proper operation.
  • Page 9 NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. The built-in test switch accurately tests the unit's operation as required by Underwriters Laboratories Inc. (UL). If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc.
  • Page 10: Backup Battery Replacement

    BACKUP BATTERY REPLACEMENT Disconnect AC power before changing battery. Shock hazard exists if AC power is miswired. This alarm uses a 9 Volt Alkaline battery. The battery should last for at least one year under normal operating conditions. The alarm has a low battery indicator, an audible "beep." It will operate at 30- 40 second intervals for a minimum of 7 days.
  • Page 11 288-3309-00...