Page 1
TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling www.diversitech.com Technical Support 1-800-995-2222...
Page 2
675-TS32 3 Heating and 2 Cooling with Extra Programmable Output Standard in all DiversiTech Touch Screen Thermostats: Complete and quick set-up with gas, oil, electric, heat pump, air conditioning and multi-stage HVAC systems. • 7 Day programmable with 4 events •...
TABLE OF CONTENTS TABLE OF CONTENTS ......................5 GLOSSARY OF TERMS......................6 DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION SELECT A LOCATION......................7 MOUNTING THE THERMOSTAT TO THE WALL ..............8 WIRING LEGEND ........................9 WIRING DIAGRAMS......................10 DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION HOME PAGE........................16 CONTROL PAGE .......................17 THERMOSTAT OPERATION MODES..................18...
SELECTING A LOCATION Anticipator control – Anticipator control Programmable thermostat – A thermo- Install your DiversiTech thermostat approximately 5 feet (1.5 meters) above the floor in an is used to turn off the heating equipment stat with the capability of automatically area with good air circulation.
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION MOUNTING THE THERMOSTAT TO THE WALL WIRING LEGEND Make sure to turn off the power supply located at the electrical service panel. All heating and cooling units should be OFF.
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION WIRING DIAGRAMS WIRING DIAGRAMS 1 AIR CONDITIONER 1 AIR CONDITIONER AND 2 HEAT I1 RC DH H C Y2 RH OBW W2 G Y1 I1 RC DH H C Y2 RH OBW W2 G Y1...
Page 7
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION WIRING DIAGRAMS WIRING DIAGRAMS 1 HEAT PUMP 1 HEAT PUMP AND 2 HEAT I1 RC DH H C Y2 RH OBW W2 G Y1 I1 RC DH H C Y2 RH OBW W2 G Y1...
Page 8
DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION DIVERSITECH TOUCH SCREEN THERMOSTAT INSTALLATION WIRING DIAGRAMS WIRING DIAGRAMS 1 TRANSFORMER 2 TRANSFORMERS I1 RC DH H C Y2 RH OBW W2 G Y1 I1 RC DH H C RH OBW W2 G Y1 HEAT...
To return to the Home Page, simply touch icon at any time! The DiversiTech thermostat Control Page provides you with an easy and intuitive screen to set your thermostat – all functions are available at the Home Page displays the following information: touch of a finger! To access the Control Page, simply touch the Home Page Screen…...
DIVERSITECH TOUCH SCREEN THERMOSTAT OPERATION THERMOSTAT OPERATION MODES TEMPERATURE SETPOINTS • Your DiversiTech thermostat can run in Program Mode or can hold a fixed • AUTO, HEAT, COOL AND OFF temperature. Based on your HVAC equipment you can quickly and easily select the mode of operation - Automatic •...
Remember it is as easy as a touch of the button. • Set-up of your DiversiTech thermostat is effortless with intuitive menu driven • FAN AUTO: The fan will run on only when there is a demand for heating or cooling.
Then select the next day of the week that you would like to have the same program setting. DiversiTech thermo- stat will then prompt you to copy the settings. Remember that you must choose Run Program from...
DiversiTech thermostat screen in a sleep mode for 15 seconds. must be activated in the Advanced Settings - page 28. • SET SCREEN: Your DiversiTech thermostat has a number of options to ensure clear viewing throughout the day and night, firstly; • Backlight: choose between Auto or ON •...
IMPORTANT INSTALLER SET-UP ing the time you are on vacation, providing energy savings and comfort for your return This DiversiTech thermostat works with many different HVAC systems – home. IMPORTANT: Heat or Cool must be selected from the Control Page before Gas, Oil, Electric Heat Pump, 2 Stage Heat Pump, 2 Stage Furnace and entering the Vacation Settings page.
º F: Choose between display units of Fahrenheit or Celsius for thermostat temperature have to re-enter through the Advanced Settings button. • SECURITY: The security settings allow you to protect your DiversiTech ther- • DAYLIGHT TIME : Choose Daylight Time On or Off dependent on your Time Zone.
ADVANCED SETTINGS – SETTING THE DIFFERENTIAL ® ® IMPORTANT: BY INADVERTENTLY MODIFYING COMPRESSOR AND THE DIVERSITECH 675-TS32 THERMOSTAT ALLOWS YOU TO CON- FURNACE SETTINGS, YOU MAY SERIOUSLY DEGRADE SYSTEM TROL UP TO 3 STAGES OF HEATING AND 2 STAGES OF COOLING, PERFORMANCE.
DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION ADVANCED SETTINGS – TIMER FEATURE ADVANCED SETTINGS – HEAT PUMP • Specify the number of minutes for which Stage 1 will function until Stage 2 is • HP “ON” when Furnace On: Heat Pump and Furnace can operate together when activated to help raise (or cool) temperature (if the temperature set point is not 2nd stage furnace is required.
If you have determined due to drafts, sunlight or other environmental factors that your Thermostat Fahrenheit Celsius thermostat needs calibration, follow this easy guide. Common causes of offset are Calibration Number Change Change lack of air circulation in the vicinity of your DiversiTech thermostat or skylights. +3.0 +6°F +3.0°C +2.5 +5°F +2.5°C +2.0 +4°F...
PIN will be erased and the ther- • To revert back to the Programmable DiversiTech thermostat, simply press the mostat will unlock. reset button and touch the screen when the message “Touch for Programmable...
- see A) at the HVAC equipment. Should a covered defect occur during the warranty period and Customer notifies DiversiTech, Customer’s sole and exclu- sive remedy will be, at DiversiTech’s sole option and expense, to repair or replace the product. Replacement products or •...
Page 21
Technical Support: 1-800-995-2222 Physical Dimensions Case: 5.75” x 4.75” x 1.25” (145mm x 120mm x 30mm) Display: 3.625” x 2.125” (95mm x 55mm) Electrical Rating 24 volt AC/DC Class 2 maximum 2 amps Temperature Accuracy +/-1°F degree Power failure protection safeguards clock and memory.
Need help?
Do you have a question about the 675-TS32 and is the answer not in the manual?
Questions and answers