Installer Setup
Name
0-gas or oil furnace equipment controls fan in
Fan Control in
heating (factory setting).
Heating
1-electric furnace thermostat controls fan in heating.
Changeover Valve
O/B Terminal
0-changeover valve O/B terminal setting.
Energized in Heating
1-changeover valve O/B terminal is energized in
or Cooling (Heat
heating.
Pumps Only)
0-heat pump backup heat source is electric (factory
Backup Heat Source
setting).
(Auxiliary Heat)
1-heat pump backup heat source is fossil fuel.
0-no external fossil fuel kit is controlling heat pump
backup heat. This thermostat controls the dual fuel.
External Fuel Fossil
Must install outdoor sensor and set Installer Setup
Fuel Kit
Number 0340 to number 2. 1-external fossil fuel kit is
controlling heat pump backup heat.
Cycles per hour (cph)
3-cph recommended for compressors (factory
for 1st Stage
setting).
Compressor
1, 2, 4, 5, 6-other cycle rate settings.
3-cph recommended for compressors (factory
Cycles per hour (cph)
setting).
for 2nd Stage
Compressor
1, 2, 4, 5, 6other cycle rate settings.
CT2001 Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu.
Settings
Notes
Only shown if conventional
system is selected. If heat
pump is chosen, fan defaults
to electric.
Only shown if heat pump
system is chosen.
Only shown if 2 heat/1 cool
or 3 heat/2 cool heat pump
is chosen.
Only shown if fossil fuel is
chosen as backup heat
source.
Only shown if two stages of
cool are selected.
Initial
Setting
Record