D SERIES ELECTRIC FURNACE
!
WARNING
1.
User MUST contact a specialized contractor when a failure occurs. DO NOT ATTEMPT to repair.
2.
When using a humidifier make sure not to damage the heating element bank.
3.
We recommend that your unit be inspected by a specialized technician once a year.
4.
Poor maintenance of air filters OR an unbalanced static pressure may result in a performance decrease.
5.
Always use genuine parts for maintenance or service call. The use of unbranded parts will void the warranty.
6.
The use of this unit without an air distribution duct will void the warranty.
7.
To assure a proper performance of your furnace, we recommend that you use high quality name brand thermostats.
8.
When the federal, provincial or state legislation comprises more restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his
own expenses.
It is strictly forbidden to use jumpers to simulate heat demand.
Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all
panels before operating. Failure to do so can result in electrical shock causing severe injuries or death.
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
MISSISSAUGA, ONTARIO L5T 1H9
WARNING
!
WARNING
!
WARNING
!
TEL.: 905-670-2500
FAX: 905-795-8311
CUSTOMER SERVICE TEL.: 1-888-882-7626
30042375B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nortron D SERIES

  • Page 1 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 D SERIES ELECTRIC FURNACE WARNING User MUST contact a specialized contractor when a failure occurs. DO NOT ATTEMPT to repair. When using a humidifier make sure not to damage the heating element bank.
  • Page 2: General Requirements And Specifications

    INSTALLATION AND OPERATING INSTRUCTIONS This furnace has been designed and manufactured to give the The safe and dependable operation of the furnace depends upon most reliable performance possible. Each unit has been given a proper installation and compliance with all national and local running inspection before shipment to assure that every component codes and standards.
  • Page 3: Operating Options

    GENERAL REQUIREMENTS AND SPECIFICATIONS ’ CONT 240 VOLTS – SINGLE PHASE TEMP. RISE @ 0.20 IN. W.C. MODEL NO. BTUH AMPS INCL. MOTOR BLOWER °C °F *SPEED 21D10 34120 MED-LOW 21D15 51180 MED-LOW 21D18 61420 MED-LOW 10” x 8” (254 mm x 203 mm) 21D20 68240 MED-LOW...
  • Page 4: Installation Notes

    E. Read the current draw on the meter and reset the anticipator to match the meter reading. FOR USE IN MOBILE HOMES D Series furnaces models 21D10, 21D15, 21D18 and 21D20 are SHALLOW DUCT AREA REQUIREMENTS certified for “L” -shape and “T”-shape shallow duct installation with...
  • Page 5: Using Optional Equipment

    USING OPTIONAL EQUIPMENT 1. TWO-STAGE OR OUTDOOR THERMOSTAT Mild “ON’’ (First Stage) Cold “ON’’ (Second Stage) (The “Season Select” switch must be in the “Mild” position). Slow Response Sequence Rapid Response Sequence Follow the directions supplied with the two-stage or outdoor Element 1 - Heat on instantly Element 1 - Heat on instantly thermostat in conjunction with the furnace wiring diagram.
  • Page 6: Service Parts

    SERVICE PARTS FL0003 REPLACEMENT PARTS KEY NO. PART NO. DESCRIPTION 30270032 Automatic Limit 30030006 Season Select Switch 30030025 Speed Selector Switch 30030368 Continuous Speed Switch 30280021 Thermostat Indicator Light 30080424 Motor 1/3 HP (21D10/15/18/23/25) 30080422 Motor 1/3 HP (21D27) 30020012 Blower Wheel 10”...
  • Page 7: Wirings Diagrams

    WIRINGS DIAGRAMS WARNING Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before operating. Failure to do so can result in electrical shock causing severe injuries or death. Open: 93.3°C (200°F) MRHTL MRHTL Critical Characteristic 1.
  • Page 8 WIRINGS DIAGRAMS ’ CONT WARNING Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before operating. Failure to do so can result in electrical shock causing severe injuries or death. Open: 93.3°C (200°F) MRHTL MRHTL HEAT 4...
  • Page 9 WIRINGS DIAGRAMS ’ CONT WARNING Risk of electrical shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before operating. Failure to do so can result in electrical shock causing severe injuries or death. HEAT 5 RLY PWR2 P2-3 HEAT5 P2-2...
  • Page 10: Troubleshooting

    TROUBLESHOOTING The first step in identifying an operational problem is to determine 1. If the furnace will not start: whether the fault is in the furnace or in the thermostat and/or its Turn the thermostat to its highest setting. If the light goes on, connecting wiring.
  • Page 11 MISSISSAUGA, ONTARIO L5T 1H9 TÉL. : 905 670-2500 FAX : 905 795-8311 TÉL. DU SERVICE À LA CLIENTÈLE : 1 888 882-7626 FOURNAISE ÉLECTRIQUE DE SÉRIE D AVERTISSEMENT L’utilisateur DOIT communiquer avec un entrepreneur spécialisé lorsque l’appareil est en panne. NE PAS TENTER d’effectuer soi-même la réparation.
  • Page 12: Exigences Générales Et Normes

    INSTRUCTIONS D’INSTALLATION ET DE FONCTIONNEMENT Cette fournaise a été conçue et fabriquée pour procurer un Cette fournaise fonctionnera de façon sécuritaire et fiable, pourvu rendement des plus fiables. Avant l’expédition, chaque appareil a qu’elle soit installée adéquatement et conformément aux normes fait l’objet d’une inspection et d’un test fonctionnel pour s’assurer et aux codes locaux et nationaux.
  • Page 13: Options De Fonctionnement

    EXIGENCES GÉNÉRALES ET NORMES SUITE 240 VOLTS – MONOPHASÉ AUGM. TEMP. À 0,20 po DE COLONNE D’EAU MODELE N° BTUH A INCLUANT MOTEUR VENTILATEUR °C °F *VITESSE 21D10 34120 MOYENNE-BASSE 21D15 51180 MOYENNE-BASSE 21D18 61420 MOYENNE-BASSE 10 po x 8 po (254 mm x 203 mm) 21D20 68240...
  • Page 14: Notes D'installation

    NOTES D’INSTALLATION 1. RETOUR D’AIR FROID 3. BRANCHEMENT ET AJUSTEMENT Le conduit de retour d’air froid peut se fixer sur l’un des côtés, DU THERMOSTAT À BASSE TENSION à l’arrière ou la base de la fournaise. (N’utiliser que des fils de classe 1 à l’intérieur des compartiments de la fournaise) Pour l’installation latérale, 4 ouvertures préamorcées de 1½...
  • Page 15 UTILISATION D’ACCESSOIRES FACULTATIFS 1. THERMOSTAT D’EXTÉRIEUR OU À DOUBLE CONSIGNE Douce activée (1 consigne) Froide activée ( 2 consigne) (Le commutateur Sélecteur de saison doit être Séquence d’activation lente Séquence d’activation rapide en position « Douce ».) Élément 1 : Chauffe instantanément Élément 1 : Chauffe instantanément Suivre les instructions fournies avec le thermostat à...
  • Page 16: Pièces De Rechange

    PIÈCES DE RECHANGE FL0003 PIÈCES DE RECHANGE N° N° DE PIÈCE DESCRIPTION 30270032 Disjoncteur à réenclenchement automatique 30030006 Commutateur Sélecteur de saison 30030025 Commutateur de Sélecteur de vitesse 30030368 Commutateur de Vitesse continue 30280021 Témoin de thermostat 30080424 Moteur 1/3 HP (21D10/15/18/23/25) 30080422 Moteur 1/3 HP (21D27) 30020012...
  • Page 17: Schémas Électriques

    SCHÉMAS ÉLECTRIQUES AVERTISSEMENT Risque d’électrocution. Débranchez la source d’alimentation électrique avant l’installation, l’entretien, la réparation ou le raccordement. Replacez tous les panneaux avant l’utilisation. Le non-respect de ces directives peut entraîner une électrocution pouvant causer de sévères blessures ou même la mort. Ouverture : 93,3°C (200°F) MRHTL MRHTL...
  • Page 18 SCHÉMAS ÉLECTRIQUES SUITE AVERTISSEMENT Risque d’électrocution. Débranchez la source d’alimentation électrique avant l’installation, l’entretien, la réparation ou le raccordement. Replacez tous les panneaux avant l’utilisation. Le non-respect de ces directives peut entraîner une électrocution pouvant causer de sévères blessures ou même la mort. Ouverture : 93,3°C (200°F) MRHTL MRHTL...
  • Page 19 SCHÉMAS ÉLECTRIQUES SUITE AVERTISSEMENT Risque d’électrocution. Débranchez la source d’alimentation électrique avant l’installation, l’entretien, la réparation ou le raccordement. Replacez tous les panneaux avant l’utilisation. Le non-respect de ces directives peut entraîner une électrocution pouvant causer de sévères blessures ou même la mort. HEAT 5 RLY PWR2 P2-3...
  • Page 20: Dépannage

    DÉPANNAGE La première chose à faire pour identifier un problème de 1. Si la fournaise refuse de démarrer : fonctionnement est de déterminer si la panne est localisée dans Régler le thermostat au niveau de chaleur maximal. Si le témoin la fournaise ou le thermostat et/ou son câblage.