Do you have a question about the SI?1000 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for BT SI?1000
Page 1
Bluetooth kitchen scale User manual Gregor Papa, Barbara Koroušić‐Seljak Computer Systems Department Jožef Stefan Institute Jamova cesta 39 SI‐1000 Ljubljana Slovenia January 21, 2012 ...
Page 2
Parts: ‐ scale with Bluetooth module ‐ USB cable with micro connector for battery charging Requirements: ‐ Android/iOS device with the BTscale application, or ‐ computer with Bluetooth connection, web browser, and internet access Description: soft touch button micro USB connector LED indicator LED indicator: ‐ blue (blinking) indicates that the scale is turned on, but without connection ‐ blue (stable) indicated that Bluetooth connection is established ‐ green (blinks) when data is transmitted through Bluetooth connection ‐ red (stable) indicates the battery charging Soft touch button ( ) usage: ‐ tap the button to turn on the scale ‐ while turned on tap the button to set tare (due to small size of the scale a tare is typically set through the BTscale application) ...
Page 3
Before the first usage on each device (phone, computer...): ‐ the device and the scale (its sample name is “SCALE‐00x”) have to be paired through the standard Bluetooth pairing procedure (PIN code is “1234”) Usage: ‐ put scale onto a flat surface ‐ turn it on by tapping the soft touch button (LED indicator turns on) ‐ start the Android/iOS BTscale application and connect to Bluetooth scale ‐ put the measured item onto the scale ‐ the weighted value is shown on the phone display ‐ the units of the weighted value can be changed by the BTscale application (default is g; also available kg, oz, lb) Precautions: ‐ the scale is not water tight and must never be submerged in water or placed into the dishwasher ‐ the scale is made of plastic (do not put on it hot items above 60°C / 140°F) Scale turns off automatically 90 seconds after the last usage (button tap or weight change). If battery is low (indication on phone display, or lack of LED indication after tapping the soft touch button): ‐ use USB cable with micro connector to connect the scale with USB port, or ‐ use an appropriate phone charger with micro USB connector Completely empty battery is fully charged in about 30 minutes (charging stops when the battery is full). ...
Page 4
Scale characteristics: ‐ 4 force sensors implemented into scale legs ‐ embedded Bluetooth module ‐ maximal weight load: 5000 g (11 lb) ‐ accuracy: 1 g (0.001 lb) ‐ battery capacity: 450 mAh (for approximately 10 working hours) ‐ size (LxWxH): 114 x 63 x 16 mm ‐ weight: 99 g ‐ no user serviceable parts (if not working please return to address below) ...
Page 5
BT Tscale – An ndroid ap plication nstallation n: ‐ down nload BTs cale.apk f from http: ://csd.ijs.s si/applicat tions/BTsc cale to you ur Android d devic ce ‐ insta all BTscale .apk on yo our device e sage: ‐ open n “Bluetoo oth scale” applicatio on on you r Android device ‐ tap m menu and choose “C Connect d device” ...
Page 6
Web application ‐ Open Platform for Clinical Nutrition (http://opkp.si): Before the scale can communicate with the OPEN, it must be paired with the computer. The pairing process needs to done only once. Pairing the scale with your Mac Turn Bluetooth on. Go to System Preferences > Bluetooth. Click the 'Set up New Device' button (+) to begin the setup process. The Bluetooth Setup Assistant should launch. Power the scale on. Select the scale entry from the list then click 'Continue'. Click 'Passcode options' and choose the option 'Use a specific passcode'. Enter the passcode '1234' and click 'OK' then 'Continue' to pair the device. After a short moment a message indicating success should be displayed. If not, repeat the pairing process checking the passcode option carefully. Pairing the scale with your Windows Turn Bluetooth on. Go to Control Panel > Printers and Other Hardware > Bluetooth Devices. Ensure the 'Devices' tab is active at the top left of the window. Click the 'Add' button at the bottom of the list to begin the setup process. Power the scale on. Tick the 'My device is set up and ready to be found' checkbox on screen. Click 'Next' to search for Bluetooth devices in range. Select the scale entry from the list then click 'Next'. Now, choose the option 'Use the passkey found in documentation'. Enter the passkey '1234' and click 'Next' to pair the device. After a short moment a message indicating success should be displayed. If not, repeat the pairing process checking the passkey option carefully. ...
Page 7
ood weigh ht logging by the sc ale . Log in (h http://opk kp.si) . Allow op pkp.si app plets to ac cess your compute . Click ‘M y food dia ary’ or ‘My y diet plan nner’ . Select a meal . Log food ds . Power o on the sca le . Put a pla ate on the e scale and d tap the b button ‘Ta are’ to res set the dis splayed va alue to ‘0’...
Page 8
Scale by: Jožef Stefan Institute Computer Systems Department Platform for Clinical Nutrition ...
Need help?
Do you have a question about the SI?1000 and is the answer not in the manual?
Questions and answers