To reset protection, turn POWER off and turn on again.
⑧ ⑧ ⑧ ⑧ FUSE
FUSE (LED)
(LED)
: LED lights when the 15A glass fuse (F202,203) has blown from
FUSE
FUSE
(LED)
(LED)
excessive Id. (Two fuses are on the PC1622V PA board.)
⑨ ⑨ ⑨ ⑨ O.HEAT
O.HEAT (LED)
O.HEAT
O.HEAT
(LED)
(LED)
(LED) : When the PA module temperature reaches 80 deg.C, the LED lights to
indicate the protection circuit has worked, and the amp will enter the
through state. (It is necessary for the cooling fan to operate for several
minutes to cool the PA module.)
(Turn the main POWER switch to off, and then on again to reset the Protection Circuits.)
(Turn the main POWER switch to off, and then on again to reset the Protection Circuits.)
(Turn the main POWER switch to off, and then on again to reset the Protection Circuits.)
(Turn the main POWER switch to off, and then on again to reset the Protection Circuits.)
⑩ ⑩ ⑩ ⑩ BAND
BAND
BAND
BAND
: Select the desired operating frequency band.
⑪ ⑪ ⑪ ⑪ METER
METER
METER
METER
: To change the multi-meter scales. Meter reads Pf, Pr, Vd, and Id.
⑫ ⑫ ⑫ ⑫ FAN
FAN
FAN (LED)
FAN
(LED)
(LED)
(LED)
: LED lights brighter when fan is running at high speed. When the
heatsink reaches 50℃ the cooling fan will switch to high-speed mode to
cool the heatsink.
⑬ ⑬ ⑬ ⑬ I I I I D D D D (LED)
(LED)
(LED)
(LED)
: LED lights when the input drain current is over 20A. This does not
mean that any damage occurred to the amplifier, but is useful for the
user to notice any stress influencing the final FET caused by high drain
current, load impedance trouble, etc. We recommend that you note the
usual condition of the lighting. When any unusual symptoms are
noticed, the user may lower the drive power from the transceiver, check
the antenna SWR, etc.
⑭ ⑭ ⑭ ⑭ MULTIMETER
MULTIMETER
MULTIMETER : Pf (Forward output power), Pr (Reflected power from antenna), Vd
MULTIMETER
(FET drain voltage), and Id (FET drain current) are shown on the scale
as selected by ⑪METER select switch.