Overview: Altronix Sav Power Supplies provide 12VDC distributed via four (4), nine (9), eighteen (18), thirty-six (36) Class 2 Rated PTC protected power-limited outputs for powering Surveillance Cameras and other 12VDC devices. Sav Reference Chart: Sav4D 5 amp 12VDC 2.5 amp* 1.5 amp 0.75 amp...
Note: Voltage will be the same for all outputs. 4. Connect cameras to be powered to the terminals marked [OUT1 through OUT4 (Sav4D)] (Fig. 2, pg. 4), [OUT1 through OUT9 (Sav9D)] (Fig. 3, pg. 5), [OUT1 through OUT18 (Sav18D)] (Fig. 4, pg. 6), [OUT1 through OUT9 on each power supply board (Sav182D)] (Fig.
Page 4
Sav4D Fig. 2 115VAC, 60Hz/ 230VAC, 50Hz power mains non power- limited Class 1 Green Lead Fig. 2a Voltage Adjustment 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used.
Page 5
Sav9D Fig. 3 115VAC, 60Hz/ 230VAC, 50Hz power mains non power- limited Class 1 Green Lead Fig. 3a Voltage Adjustment 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used.
Page 6
Sav18D Fig. 4 115VAC, 60Hz/ 230VAC, 50Hz power mains non power- limited Class 1 Green Lead Fig. 4a Voltage Adjustment 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used.
Page 7
Sav182D Fig. 5 115VAC, 60Hz / 230VAC, 50Hz power mains non power-limited Class 1 Green Lead Black Lead White Lead 12VDC power outputs 12VDC power outputs (For wiring utilize (For wiring utilize knockouts on knockouts on the the right hand side of enclosure) left hand side of enclosure) Class 2 not wet, Class 3 wet,...
Page 8
Sav36D Fig. 6 115VAC, 60Hz / 230VAC, 50Hz power mains non power-limited Class 1 Green Lead Black Lead White Lead 12VDC power outputs 12VDC power outputs (For wiring utilize (For wiring utilize knockouts on knockouts on the the right hand side of enclosure) left hand side of enclosure) Class 2 not wet, Class 3 wet,...
Page 9
Note: Keep power-limited wiring separate from non power-limited. Use minimum 0.25” spacing. Ring Please refer to the SAV DC Power Supplies Installation Guide’s wiring diagram. 2. Insert AC line cord with integral strain relief through the desired enclosure knockout (Fig. 8).
Page 10
Wiring AC line cord for models SAV4D, SAV9D and SAV18D: 1. Connect black lead to terminal marked [L]. Connect green lead to terminal marked [G]. Connect white lead to terminal marked [N] (Fig. 11). Fig. 11 White Lead Green Lead...
Page 11
Enclosure Dimensions for Sav4D, Sav9D and Sav18D: 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm) 7.25” (184.15mm) 3.625” (184.15mm) 1.25” (31.75mm) 3.5” (88.9mm) 0.6” 0.6” 1.25” 6.05” (15.24mm) (15.24mm) (31.75mm) (153.67mm) 1.125” 1.125” (28.575mm) (28.575mm) 2” (50.8mm) 2”...
Page 12
Enclosure Dimensions for Sav182D and Sav36D: 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm) 1.40” 4.85” 4.85” 1.40” (36mm) (123mm) (123mm) (36mm) 1.20” (31mm) 3.25” (83mm) 12.5” (318mm) 1.20” 1.20” 0.75” 0.75” (31mm) 11.0” (31mm) (19mm) (19mm) (279mm) 0.9375”...