Tando RTR-500NW Introductory Manual

Network base station
Table of Contents

Advertisement

Quick Links

Network Base Station
RTR-500NW
RTR-500AW
Introductory Manual
Thank you for purchasing our product. This manual
explains in brief how to get an RTR-500NW/500AW
unit ready for use and how to install the software.
Details about how to use the software "RTR-500W
for Windows" and its functions can be found in the
software "Operation Guide (Help)".
© Copyright T&D Corporation. All rights reserved.
2011.05 16507060008 (2nd Edition)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTR-500NW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tando RTR-500NW

  • Page 1 RTR-500AW Introductory Manual Thank you for purchasing our product. This manual explains in brief how to get an RTR-500NW/500AW unit ready for use and how to install the software. Details about how to use the software "RTR-500W for Windows" and its functions can be found in the software "Operation Guide (Help)".
  • Page 3: Table Of Contents

    4. Repeater Registration (Only if necessary) ------ 38 What are "Base Units", "Remote Units" and "Repeaters"? ----------------------------------------12 Notes about Operation Base Unit: RTR-500NW / RTR-500AW ------------ 12 Before Using ---------------------------------------40 Remote Unit: RTR-501502/503/574/505 ----------- 12 Connecting the AC Adaptor --------------------------- 40...
  • Page 4: Introduction

    Notices Carefully read this manual so that you can properly use this product. T&D Corporation accepts no responsibility for any malfunction of and/ or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair of the attached warranty.
  • Page 5: Software User Agreement

    Software User Agreement Disclaimers - T&D Corporation does not guarantee the operation of RTR-500W for Windows. - T&D Corporation shall not accept any responsibility for any damage, whether direct or indirect, that results from the usage of RTR-500W for Windows. - Specifications of RTR-500W for Windows may be subject to change and service may be terminated without advance notice to the user.
  • Page 6: Safety Precautions And Instructions

    Safety Precautions and Instructions The following items should be strictly obeyed for the safe usage of this Unit, and for protecting yourself and other people from bodily harm and/or damage to property. Before using this product, please read the following carefully and fully understand the contents.
  • Page 7 DANGER When installing and using this Unit, make sure to follow all warnings and directions from your computer manufacturer. Do not take apart, repair or modify the Unit. Doing so may cause fire or electrocution. If water or a foreign body enters the Unit, immediately disconnect AC adaptor and communication cables, and stop using.
  • Page 8 CAUTION Please note that this Introductory Manual has been written based on the presupposition that details about contracts with an Internet provider, specific network environments and the set-up of any other necessary equipment to enable network connection has already been taken care of by the User and that connection has been confirmed as workable.
  • Page 9 Do not put anything on top of the AC adaptor. This may cause overheating. To prevent damage to the Unit from static electricity, remove static electricity from your body by touching metal around you (door knob, window frame) before touching the Unit. Static electricity may cause not only damage to the Unit, but may cause breaks in or a loss of data.
  • Page 10 Notes and Precautions for Installing Wireless Communication Devices When installing wireless communication devices take special care in selecting locations so as to ensure proper communication. Note that even after a successful installation, due to changes in environmental conditions, communication errors may occur when restarting the system. As far as possible, try to keep wireless communication devices away from metals and set them up in high unobstructed positions.
  • Page 11: Compliance Information

    Compliance Information Radio, EMC and Safety Regulations This device complies with Part 15 of the Federal Communications Commission (FCC) rules and with RSS-210 of the Industry Canada (IC). Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.
  • Page 12: Features Of Rtr-500Nw/500Aw

    Reports / Check Current Readings Wireless LAN T&D Webstorage Service After having registered an RTR-500NW/500AW as a Base Unit and making various settings, the Unit will automatically carry out a series of actions according to settings. It can be set up to periodically download recorded data and current readings from Remote Units, and send this data via e-mail to specified addresses, or by FTP to a server including T&D’s WebStorage Service.
  • Page 13: Make Registration Changes Via Network

    Make Registration Changes via Network After making initial settings via USB it is possible to make all registration changes and settings via network. Monitoring Current Readings and Viewing Recorded Data via Web Browser By sending recorded data or current readings to the T&D WebStorage Service it is possible to check and share data via a web browser.
  • Page 14: What Are "Base Units", "Remote Units" And "Repeaters

    What are "Base Units", "Remote Units" and "Repeaters"? Base Unit: RTR-500NW / RTR-500AW Base Unit collects via wireless communication current readings and data measured by and recorded in Remote Units as well as monitors for warnings. Remote Unit: RTR-501/502/503/574/505 A Remote Unit is a Data Logger designed to measure and record various items such as temperature, humidity and so on.
  • Page 15: About Registration

    About Registration It is first necessary to register Remote and Repeater Units (where needed) to a Base Unit. It is possible to register them into Groups by place or by purpose. A Wireless Communication Frequency Channel is then assigned to each Group to help avoid interference and poor transmission.
  • Page 16: Basic Procedure Flow

    Basic Procedure Flow The following shows the basic flow of procedures. Details about contracts with an Internet provider, specific network environments and the set-up of any other necessary equipment to enable a network connection should be taken care of by the User. Before getting started the connection should be confirmed as workable.
  • Page 17: Getting Ready

    Getting Ready This section explains what needs to be done before registrations and settings can be made. Package Contents --------------------------------16 Connecting the Antenna ------------------------------- 16 Appearance Diagram and Part Names -------17 Installing the Software ----------------------------19 Before Installing the Software ------------------------- 19 Procedure for Installing the Software --------------- 20 About USB Device Drivers ----------------------23 Procedure for Installing...
  • Page 18: Package Contents

    Please check that he following items are included in the package: RTR-500NW or Antenna USB Communication LAN Cable (LN-20W) RTR-500AW Cable (US-15C) *Only use for RTR-500NW AC Adaptor Software Introductory Manual (AD-0638) CD-ROM (This Manual including warranty) Make sure to install the software before connecting the Unit to a PC with the USB cable.
  • Page 19: Appearance Diagram And Part Names

    Appearance Diagram and Part Names Front and Bottom (Unit:mm) Antenna Optical Communication Area POWER LED ACTIVE LED DIAG (Diagnosis) LED ALARM LED External Input Terminal External Output Terminal Getting Ready...
  • Page 20 Sides Right Left RTR-500NW RTR-500AW (Unit:mm) LAN Cable Connector (RTR-500NW only) AC Adaptor Jack USB Mini Connector (Mini-B) From hereafter in this manual, RTR-500NW/500AW units will be referred to as the "Unit". Getting Ready...
  • Page 21: Installing The Software

    Installing the Software Make sure to install the software before connecting the Unit to a PC with the USB cable. If you have connected a Unit to your computer before installing the USB device driver, make sure to click the [Cancel] button in the Wizard window when it pops up on the computer display.
  • Page 22: Procedure For Installing The Software

    Procedure for Installing the Software This explanation uses displays from Windows XP SP2. - If your OS is Windows Vista or Windows 7, the window layout may be slightly different. However, the message contents and the button operations are the same, so please follow the directions as written below.
  • Page 23 4. The "RTR-500W for Windows" Setup Wizard window will appear. Click the [Next] Button 5. The "Software License Agreement" window will appear. Please read all the terms stipulated in the agreement. Check "I accept the terms of the license agreement" if you accept the terms.
  • Page 24 7. The "Ready to Install the Program" window will appear. Click the [Install] Button to begin installation. Although a warning message such as below may appear, there is no problem, please move on to the next step. Warning Message For Windows Vista and Windows 7 For Windows XP Click the [Install] Button Click the [Continue Anyway] Button...
  • Page 25: About Usb Device Drivers

    Upon connecting a Unit to your PC, the [New Hardware Detection Wizard] will automatically open. Please carry out the procedures on the following pages to install the USB Device Drivers for the Base Unit (RTR-500NW / 500AW), Remote Units (RTR-574), and if necessary, Repeaters (RTR- 500).
  • Page 26: Procedure For Installing The Base Unit Usb Device Driver

    Procedure for Installing the Base Unit USB Device Driver Carry out all USB Device Driver installations for only one Unit at a time. Users of Windows XP should carry out the following procedure to install the USB Device Driver. 1. By connecting a Base Unit to your computer, the [New Hardware Detection Wizard] will automatically open.
  • Page 27 If a warning message window appears, click the [Continue Anyway] button, and continue with the installation. 3. Once the completion message appears, installation has finished. Click the [Finish] Button. - See page from 28 of this Manual for about how to confirm that the USB Device Driver has been properly installed.
  • Page 28: Procedure For Installing The Rtr-574 / Repeater Usb Device Driver

    Procedure for Installing the RTR-574 / Repeater USB Device Driver Carry out all USB Device Driver installations for only one Unit at a time. Users of Windows XP should carry out the following procedure to install the USB Device Driver. 1.
  • Page 29 Check "Install the software automatically (Recommended)". Click the [Next] Button. 2. The installation process will begin. If a warning message window appears, click the [Continue Anyway] button, and continue with the installation. 3. Once the completion message appears, installation has finished.
  • Page 30: Checking A Usb Device Driver

    Checking a USB Device Driver Check the USB Device Driver installation for one device at a time. The checking procedure is the same for the Base Unit, Remote Units and Repeaters. Check using the following steps: 1. Open the Device Manager window. Procedure example: In the Windows Start Menu, click on "Control Panel"...
  • Page 31 Click on "System". In the System Properties Window, click on the [Hardware] tab. Click the [Device Manager] Button. 2. Connect the target Unit to the computer with a USB cable and look at the icon displayed in the Device Manager window in order to check whether or not the USB Device Driver has been properly installed.
  • Page 32 If the icon appears with an " ? " or an " ! ", the PC is not properly recognizing the Unit. Windows XP Windows Vista / Windows 7 3. If your PC does not properly recognize a Unit, please re-install the USB Device Driver by following the directions on the next pages.
  • Page 33: Re-Installing The Usb Device Driver

    Re-installing the USB Device Driver 1. Right click on the icon. 2. From the pop-up menu click on "Properties" . 3. When the following window appears, click on the [Reinstall Driver] button to display the Wizard window. [General] Tab Window [Reinstall Driver] Button Getting Ready...
  • Page 34 4. If you are using Windows XP, please follow the directions below and move on to step 6. Check the "Install from a list or specific location (Advanced)". Click the [Next] Button. Check the "Include this location in the search:". Click the [Browse] Button.
  • Page 35 Click the [Browse] Button. 6. Specify the location of the Driver. Click the plus (+) sign next to the folder into which the software was installed and specify "Device Driver" as the driver location. Click the [OK] button to return to the Wizard window.
  • Page 36 8. The installation process will begin. Please note that the following warning messages may appear during installation. However, this will cause no problems with USB device driver installation. Please move on to the next step. Warning Message For Windows XP For Windows Vista and Windows 7 Click the [Install] Button Click the [Continue Anyway] Button...
  • Page 37 Registering Devices and Making Settings This section explains a few items that need to be checked before registering devices and making settings and the basic processes of both. About Applications and the Operation Guide -----------36 How to Open ---------------------------------------------- 36 Registering Devices and Making Settings ---37 1.
  • Page 38: Making Settings

    About Applications and the Operation Guide How to Open Click on Windows [Start] - [All Programs] - [RTR-500W for Windows] and then click on the item in the Menu which you wish to open. MENU: - RTR-500W Settings Utility: For Base Unit, Remote Unit and Repeater Registration and Settings - Temperature / Humidity Graph: Use to view RTR-501 / 502 / 503 / 505 recorded data - Multi-scale Graph:...
  • Page 39: Registering Devices And Making Settings

    Registering Devices and Making Settings This section briefly explains in sequence what needs to be done in order to carry out registration of devices and the making of settings. 1. Base Unit Settings Before making initial settings please confirm the following: Is the Unit connected to a PC with the USB cable? Are the "POWER"...
  • Page 40: Base Unit Operational Settings

    Remote Unit Registration Items Items that are registered into the Remote Unit include Group Name, Remote Unit Name, Frequency Channel Settings, Recording Mode Settings, Warning Monitoring Settings, Auto-Download Settings and so on. 3. Base Unit Operational Settings Next please make all Base Unit operational settings from the Menu of the RTR-500W Settings Utility.
  • Page 41: Notes About Operation

    What is the External Contact Input? ---------------- 43 Installing and Removing Wires ----------------------- 43 Uninstalling the Software ------------------------44 FAQ ----------------------------------------------------46 Q&A about the Unit RTR-500NW/500AW --------- 46 Product Specifications ----------------------------48 RTR-500NW/500AW ------------------------------------ 48 Software (RTR-500W for Windows) ----------------- 49 Options -----------------------------------------------50...
  • Page 42: Before Using

    Connecting the AC Adaptor When ready for actual operation, disconnect the USB cable from the Base Unit and supply power by connecting to the supplied AC adaptor. When using RTR-500NW, please connect the LAN cable to the HUB before supplying power.
  • Page 43: Useful Features And Functions

    Useful Features and Functions Changing Settings during Operation It is possible to make changes to settings by either connecting the Unit to the same computer used when making the initial registration with a USB cable or via a network connection. When making changes to settings keep the following two points in mind.
  • Page 44: Led Lamp Display

    LED Lamp Display POWER ACTIVE ALARM DIAG Status Reason Probable Causes Power ON POWER Power OFF - A measurement has exceeded one of the set limits. Warning - The contact input is ON. Occurrence - There is trouble in the Remote Unit (battery ALARM level is low, a sensor connection is poor), etc…...
  • Page 45: External Contact Output / Input Terminals

    External Contact Output / Input Terminals What is the External Contact Output? When the "ALARM" LED lamp goes on, the external output simultaneously goes ON. If you wish to connect a buzzer, light or other warning device to the external output terminal please see the following important information.
  • Page 46: Uninstalling The Software

    Uninstalling the Software Before running the uninstall program, make sure to quit all software applications. If it is necessary to uninstall the software please follow the steps below: 1. In the Windows Start Menu, click on "Control Panel" to open. Windows XP Click the "Add or Remove Programs".
  • Page 47 3. From the list of currently installed programs, select "RTR-500W for Windows" and click the [Remove] Button or the [Uninstall] Button. Windows XP Click the [Remove] Button Windows Vista / Windows 7 Click the [Uninstall] Button 4. The "Install Shield Wizard" window will appear. Place a check next to [Remove], and click the [Next] button.
  • Page 48: Faq

    You will need some device through which you can physically connect the RTR-500NW/500AW to a Network and also a server to act as the recipient of data and warnings. Details about what is necessary will depend on your operating...
  • Page 49: Factory Default Settings

    Q4: How can I return the RTR-500NW/500AW back to its original factory default settings? Connect the target RTR-500NW/500AW to your PC with a USB cable. In the RTR-500W Settings Utility , under the [Operations] Menu, select [Return Base Unit to Factory Default Settings] and the settings will be returned to the default factory ones.
  • Page 50: Q&A About Settings

    - Check the USB connection between the computer and the RTR- 500NW/500AW. If there is a proper working connection the ACTIVE LED (green) on the RTR-500NW/500AW should be ON. Checking your Computer - Make sure that the software has been installed properly and is working.
  • Page 51: Software (Rtr-500W For Windows)

    For RTR-574 - Check the USB connection between the computer and the RTR-574. - Make sure that the supplied software has been installed properly and is working. - Use your computer's Device Manager to check whether or not the USB device driver has been installed properly.
  • Page 52: Product Specifications

    RTR-500AW: Approx. 400mA Communication Interfaces USB (with PC) Optical Communication (with Compatible Remote Units other than RTR-574) Wired LAN (RTR-500NW) / Wireless LAN (RTR-500AW) LED Display POWER, ACTIVE, DIAG, and ALARM Dimensions H83mm x W102mm x D28mm (excluding protrusions) Antenna Length: 87.3mm...
  • Page 53: Operating Environment

    Maximum Input Voltage: 30V Software (RTR-500W for Windows) Operating Environment Compatible Base Units: RTR-500NW, RTR-500AW Devices Remote Units: RTR-501 / 502 / 503, RTR-501L / 502L / 503L, RTR-574 RTR-505-TC / 505-Pt / 505-mA / 505-V / 505-P Repeater: RTR-500...
  • Page 54: Options

    Options Wall Attachment TR-5WK1 Materials: PC Resin Screw for fastening to wall x 2 Double-sided Tape x 1 Screw for fastening Unit x 1 Dimensions: W106 x H86 x D17.8mm Screw holes: 2 - ø3.2mm Usage Figure Notes about Operation...
  • Page 55 Introductory Manual downloads, as well as, other support. Please stop by and see what we have to offer. Network Base Station RTR-500NW/500AW Introductory Manual Published by T&D Corporation © Copyright T&D Corporation. All rights reserved.
  • Page 56: Warranty

    RTR-500NW/500AW Warranty Network Base Station Provisions for Free Repair RTR-500NW RTR-500AW The warranty is contained in the User’s Manual (English) included in the package. 1 year from date of purchase Warranty Period When seeking repair, please make sure to fill in all required fields and present it.