  • Page 1 MODEL TRIMMER MODEL MT10, MT12, and MT15 Operating and Maintenance Instructions Sales, Service, and Technical Assistance Call Toll Free 800 / 654-4519 Ray Foster Dental Equipment 5421 Commercial Drive Huntington Beach, CA 92649 714 / 897-7795, Fax 714 / 898-6013...
  • Page 2: Important Saftey Instructions

    INTRODUCTION Thank you for purchasing a quality Foster product. Your Foster Model Trimmer is designed to give years of trouble free service with minimal care and maintenance. Before putting your new machine to work, please become familiar with this operator's manual to obtain maximum performance and satisfaction. IMPORTANT SAFTEY INSTRUCTIONS WARNING! When using electrical tools, basic safety precautions should always be followed to reduce the risk of fire, electrical shock, and personal injury...
  • Page 3: Installation

    Wear Proper Clothing. Do not wear loose clothing or jewelry, which may get caught in rotating parts. Tie back long hair. Maintain the Unit. Inspect periodically for damaged or worn parts. Follow the instructions for maintenance. Don’t use if the power cord, motor, switch, or other parts are in poor condition.
  • Page 4: Excessive Vibration

    ELECTRIC MOTOR The motor installed on Foster model trimmers is equipped with permanently lubricated, sealed ball bearings. No lubrication or maintenance is required. DOOR SECURE When closing and securing the door, do NOT tighten the door secure knob. It is only necessary for the door to "touch"...
  • Page 5 2. If the vibration is still present with the wheel removed, the problem lies with the aluminum back plate (P/N M222 for MT10, P/N M221 for MT12 and MT15). The backing plate must be removed and cleaned of all plaster, or replaced.
  • Page 6 ACCESSORIES FOR FOSTER MODEL TRIMMERS Automatic Solenoid Water Valve – Cat. No. M008 Turns the water on and off automatically and simultaneously with the motor. A great convenience item. Comes complete with illustrated instructions for easy installation. Sediment Tray – Cat. No. M006 Helps keep the counter free of splash and drippings.
  • Page 7: Parts Diagram

    PARTS DIAGRAM...
  • Page 8: Parts List

    PARTS LIST When ordering replacement parts always include machine model number and serial number as well as individual part number. REF. PART NUMBER NUMBER DESCRIPTION M009.................Screw, Switch Box Attach M020..................Switch Mounting Box M024..................Rubber Switch Cover M081....................Motor Switch M138..................Electric Power Cord M201................Motor Mount Bolt (4 required) M202..................
  • Page 9 Huntington Beach, California. At its option, Ray Foster Dental Equipment Company will replace or repair the defect free of charge, providing the Model Trimmer has not been subjected to abuse, neglect, damage, or used in a capacity other than which was intended.