Table of Contents INTRODUCTION ................................3 CONTENTS OF WOS-SERIES OIl/WaTER/SOlIDS SEpaRaTOR ................4 SpECIFICaTIONS ................................4 IMpORTaNT SaFETy WaRNINGS ..........................5-7 RISK OF ElECTRIC SHOCK OR ElECTROCUTION ..................... 5 RISK OF EXplOSION OR FIRE ..........................6 RISK OF BURSTING ..............................6 RISK OF BURNS ..............................
Mi-T-M Oil/Water/Solids Separator. The contents of this manual are based on the latest product information available at the time of publication. Mi-T-M reserves the right to make changes in price, color, materials, equipment, specifications or models at any time without notice.
ConTEnTS oF WoS-SEriES oiL/WaTEr/SoLiDS SEparaTor Carefully unpack your new Mi-T-M WOS-Series Oil/water/solids separator. Check the contents against the packing list. Contact the freight line if a damage claim is required on any component. The following items are the basic equipment sent with your WOS-Series Oil/water/solids separator.
From moVinG parTS Serious injury may occur to the Do not operate the unit without all operator from moving parts on the protective covers in place. oil/water/solids separator. Follow the maintenance instructions specified in the manual. Mi-T-M WOS-SERIES Operator's Manual ®...
Know how to stop the oil/water/solids separator. Be thoroughly familiar with controls. Before servicing, alWayS shut off the oil/ water/solids separator. !SaVE THESE inSTrUCTionS! Mi-T-M WOS-SERIES Operator's Manual ...
WaTEr SEparaTor SYSTEm FLoW CHarT Mi-T-M WOS-SERIES Operator's Manual ®...
Page 9
2. Water Outlet Valve 2: When this valve is open and the Pit Return Valve 3 is closed, water flows through the Water Outlet Valve 2 to be used as desired. WX-OPTION: The Pit Return Valve 3 must be opened and the Water Outlet Valve 2 must be closed for auto- discharge. Mi-T-M WOS-SERIES Operator's Manual ...
Page 10
Oil/Water/Solids Separator level limit Switch Ozone Contact Tank Sump pump Receptacle Separator Tank power Supply Switch (On/Off) Oil Coalescing Grid power Cord w/20 amp plug Oil Skimmer Control panel Waste Oil Decanter Outlet to Discharge Mi-T-M WOS-SERIES Operator's Manual ®...
. a Collection pit System must already be an established structure before installing the WOS-Series oil water separator system. a well designed pit system is critical for the proper operation of the recycle system. Consult your Mi-T-M dealer for installation requirements.
Water Inlet Flow Control Valve 1. Maximum flow is achieved when the water level remains constant in the Holding Tank (15). 6. Water is now completely cycled in the system. Mi-T-M WOS-SERIES Operator's Manual ...
4. Remove the drain plug from the solids collection area on the Separator Tank (9) and clean the tank. 5. Remove the plug from the Waste oil Decanter (12) and drain. 6. Remove the remaining drain plugs from the oil/Water/Solids Separator (7) and wipe down the oil/Water/Solids Separator (7). Mi-T-M WOS-SERIES Operator's Manual ®...
Cycle pump in one minute increments several times to clear air from pump. If system includes a check valve, a 3/6" hole should be drilled in the discharge pipe approximately 2" above the discharge connections. Mi-T-M WOS-SERIES Operator's Manual ...
Short seal life. Unexpected temperature and Replace. chemical usage. WATER flOW air shoots from Water Outlet. This is a common occurrence while air will stop shooting from the water pump is priming. outlet when pump is primed. Mi-T-M WOS-SERIES Operator's Manual ®...
There are no warranties which extend beyond the description of the face hereof. Under no circumstances shall Mi-T-M bear any responsibility for loss of use of the unit, loss of time or rental, inconvenience, commercial loss or consequential damages.
Page 20
Manufactured by Mi-T-M 8650 Enterprise Drive, peosta Ia 52068 563-556-7484/ Fax 563-556-235 Mi-T-M WOS-SERIES Operator's Manual ®...
Need help?
Do you have a question about the WOS-SERIES and is the answer not in the manual?
Questions and answers