Stuart SRC14 Instructions For Use Manual

Recirculating cooler
Hide thumbs Also See for SRC14:

Advertisement

Quick Links

Recirculating Cooler
SRC14
Instructions for use
Version 2.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRC14 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stuart SRC14

  • Page 1 Recirculating Cooler SRC14 Instructions for use Version 2.0...
  • Page 2: Electrical Installation

    This model requires a supply rated at 220 - Introduction 240V, 50 Hz, ~, single phase. Thank you for purchasing this piece of Stuart equipment. Model Supply requirements Power To get the best performance from the equipment and for...
  • Page 3: General Description

    The SRC14 accurately controls the temperature of a cooling liquid between -20 to +30ºC. The cooled liquid is then circulated to an external device via the inlet and outlet nozzle. The SRC14 has a capacity of 14 litres. Safety Advice Before Use •...
  • Page 4: Maintenance And Servicing

    (calibration can only be performed between +9.9ºC and -9.9ºC). After setting Cooling liquid the correct value press the set key for more than 5 filter seconds, the display will return to the current measured temperature. Sensor Fig.5 SRC14...
  • Page 5: Warranty

    Bibby Scientific Ltd warrants this instrument to be free the unit. To change the fuse on the SRC14, switch off from defects in material and workmanship, when used the mains power. Insert a small screwdriver into the slot under normal laboratory conditions, for a period of three and push downwards, as shown in Fig.
  • Page 6: Instructions For Use

    Instructions for use Note: Alarm is cleared by turning off the power switch Problem Cause Solution Cooling liquid is not Cooling liquid filter is blocked. Clean the filter – See the Maintenance and circulated. Servicing section for details. Air is trapped in the pump. Briefly remove the drain stopper.
  • Page 7 This product meets the applicable and so we cannot guarantee that interference EC harmonized standards for radio will not occur in practice. Where there is a frequency interference and may be possibility that injury, damage or loss might occur expected not to interfere with, or be affected if equipment malfunctions due to radio frequency by, other equipment with similar qualifications.
  • Page 8: Inspection Report

    INSPECTION REPORT MODEL SRC14 ELECTRICAL SAFETY 1. Earth continuity 2. Insulation 3. Flash test FUNCTIONAL 1. Indicators 2. Speed/temperature 3. Visual acceptance QUALITY CONTROL INSPECTOR Bibby Scientific France SAS Bibby Scientific Italia Srl ZI du Rocher Vert - BP 79...