Texts and illustrations have been compiled and software created with the utmost care, however errors cannot be completely ruled out. This documentation is therefore supplied under exclusion of any liability or warranty of suitability for specific purposes. FHF reserves the right to improve or modify this documentation without prior notice.
Page 3
Intercom Station IntellyCom with casing Loudspeaker Microphone Loop Current Indicator Hook switch 3 / 18...
Intercom Station IntellyCom built-in unit assembly cut-out thread M4 or Ø 4.3 mm 4 / 18...
Page 5
Connection Opening the Intercom Station To gain access to the circuit board or the tamper alarm switch, unfasten the four screws in the front panel. Attention: Before opening or dismounting the device it has to be separated from all voltage supply. Concluding notes CE (cable entry) M20 x 1.5...
Page 6
Relay contact output The Intercom Station board comprises a relay contact which can be activated from a remote telephone or telephone system. This relay can control for example electric door entry mechanism, signaling and other electrical devices. The voltage at the relay contact terminals shall not exceed 60 V or 30 V .
Operation Making a Call Press the on/off button. The loop current indicator light blinks to indicate that a connection is being made, and changes to the continuous “on” state, when the receiving party answers the call. To converse with your respondent, speak in the direction of the Intercom station from a distance of about 30 cm.
Page 8
Programming The Intercom Station IntellyCom is designed to be programmed remotely over the telephone line. Programming is carried out using sequences keyed from a telephone, when connected to the IntellyCom to be programmed. Remote programming codes are split into two classes Class 0 and Class 1 which are distinguished by different enclosing characters;...
Page 9
*101disablebusy* Set up option "Disable in case of busy tone" disablebusy=0 Disable in case of busy tone activated disablebusy=1 Disable in case of busy tone deactivated Delivery condition: disablebusy=0 Disable in case of busy tone activated *102ringback* Set up option "Ring back schema" ringback=0 Ring back schema 2 ringback=1 Ring back schema 24 ringback=2 Ring back schema 246...
Page 10
*142duplex_profile* Set up duplex profile of voice communication duplex_profile=0-4 (full duplex -semi-duplex) Delivery condition: duplex_profile=0 full - duplex Remark: In case of inappropriate electrical and/or acoustic installation conditions co-coupling effects (whistler) may occur. In those cases modify the regulation of the profile in to the higher values (semi-duplex).
Page 11
*3000*accesscode* Access Code accesscode=0000-9999 except: 0600, 0990 and actual relaycode Factory setting: accesscode=1234 *32t_button_pressed_ Duration for which button must be pressed before_onhook* continuously for clear down to take place t_button_pressed_ before_onhook=05-99 *0.1 seconds Factory setting: t_button_pressed_ before_onhook=20 = 2 seconds *5000*phone_id* Program Intercom Station ID phone_id=0-9999...
Page 12
*5005* telephone number* Program memory M5 Factory setting: empty Note: Number chaining ends with memory M4 if memory M5 is empty. M5 is cleared with *5005** *5006* telephone number* Program memory M6 Factory setting: empty Note: Number chaining ends with memory M5 if memory M6 is empty.
Page 13
Defining Call Procedures To Define a Call from the Speed Dial Telephone Number List You can define this call scenario by programming a maximum of 8 desired telephone numbers in the number list memory M1-M8. After pressing the on/off button, the station then attempts to connect to the programmed numbers beginning with M1 in ascending sequence.
Page 14
*2015* Set minimum ringing duration to 15 sec, for example, to define how long IntellyCom should wait for the line dialed to the private branch exchange before it considers the connection failed and shuts off. Set the minimum ringing duration to “unending” by entering *2000*, if you want to determine yourself when the connection has failed by shutting it off manually.
Page 15
To Define Manual Call Acceptance You can define this call acceptance scenario by setting the programmed ring/signal counter *11xx* (3) to the value “99”. Incoming calls will then be acoustically optically signaled, and only accepted when the on/off button is pressed. Example: #1234# Receive programming authorization.
Page 16
You can manually stop the muting function by a short activation of the activation button and/or by selecting that IntellyCom ring back schema, which is able to distinguish earliest language and ring back tones. A reliable identification of the call begin cannot be guaranteed with none of the ring back schemas, schema 2 offers the lowest error rate.
Page 17
Connection information Input terminal voltage 24 V to 66 V from the telephone connection Power supply current 28 mA to 100 mA Call signal voltage 35 V to 90 V (23…54 Hz) Larger 5.5 kW at 25 Hz and 30…90 V Call signal impedance Larger 4.0 kW at 50 Hz and 30…90 V Dual-tone multi-frequency signalling (DTMF)
Page 18
Subject to alterations or errors FHF Funke + Huster Fernsig GmbH Gewerbeallee 15-19 · D-45478 Mülheim an der Ruhr Phone +49 / 208 / 82 68-0 · Fax +49 / 208 / 82 68-286 http://www.fhf.de · e-mail: info@fhf.de...