ENGLISH WARNING Arc welding and cutting can be dangerous to the user, people working nearby, and the surroundings if the equipment is handled or used incorrectly. Therefore, the equipment must only be used under the strict observance of all relevant safety instructions.
INITIAL OPERATION Mains connection Usage of the machine The machine should be connected to a mains supply When welding, a heating of various components of and must be correctly earthed. After the mains plug the machine takes place and during breaks these has been connected to the mains the machine is components will cool down again.
MAINTENANCE TECHNICAL DATA Insufficient maintenance may result in reduced operational reliability and could invalidate guarantee. NXT200 AC/DC Mains voltage 1x230 V The NXT welding machines require virtually no PFC (power factor correction) maintenance. However, exposure to extremely Duty cycle 100 % TIG 140 A 40°C...
INITIAL INSTRUCTIONS All "parameters" are set by the use of only one Input voltage variations control knob. These parameters include current, The mains error indicator is illuminated if the pulse time, slope-up time, etc. mains voltage is more than 15% lower or higher than the rated voltage.
Page 7
TIG welding SLOPE DOWN SLOPE UP The parameters can be adjusted with the knob after START they are shown on the display. STOP Press the relative key to select the parameter. The relevant LED will lit. Four-times: The welding process begins by pressing the torch trigger.
Page 8
Post-flow [s]: Electrode pre-heating (TIG AC) Post-flow is the period of time for which gas Pre-heating of the electrode will improve the ignition. flows after the arc is extinguished and is variable 0- It is possible to select 15 levels of pre-heating. It is 20 sec.
Page 9
Reset It is possible to recall all factory standard parameters. In this case the program of the machine will be TIG AC, 2-times, HF with the following parameters: • MMA current 80A • TIG Current 80A • TIG Spot Current 80A •...