Glass Panel Removal; Burner Flame Adjustment - Desa GW30B Installation Instructions Manual

Gravity direct vent wall furnace
Table of Contents

Advertisement

5. To remove the logs from shrink wrap, carefully cut the
plastic around the perimeter of log. Do not tear the logs from
package with out cutting plastic first.
6. Carefully place the log set as shown in the figure below.
The front and rear logs can be placed either with the split oak
or round oak showing, depending on personal preference.
Regardless of which side of the front and rear logs are
showing, the twigs will remain in the same position.

GLASS PANEL REMOVAL

LEFT TWIG
FRONT LOG
LOG ASSEMBLY
7. Front and rear logs have slots for brackets. Be careful not
to alter the pilot or burner location.
8. Next remove the ceramic fiber embers from the bag and
place small pieces on top of burner ember tray located on the
very front of burner with grate. Avoid blocking burner ports
when placing embers.
9. When closing the glass door, make certain the safety door
switch is fully depressed by the door. The burner will not turn
on if the door switch is not fully depressed. Replace the
louver assembly in the reverse order of step 1.
BURNER REMOVAL
BEFORE PROCEEDING, MAKE SURE THE ENTIRE
UNIT IS COOL.
REAR LOG
RIGHT TWIG
Remove the louver assembly.
Open the four latches and swing the door to the left.
Remove the logs.
Remove the screw that attaches the pilot to the burner.
Slide the burner to the right, lift up, and remove from
firebox.
To put the burner back, place the burner to the right inside
the firebox. Slide the burner to the left.
Make certain the orifice is inside the venturi tube when
sliding the burner to the left.
Secure the pilot to the burner with the screw.

BURNER FLAME ADJUSTMENT

The air shutter, located at the base of the main burner has been
factory preset to the proper air-to-gas ratio which results in an
even, clean burning flame cross the burner.
If readjustment is necessary, you can restore the proper flame
setting by loosening the air shutter screw and rotating the air
shutter until proper flame setting is achieved. Don't forget to
retighten screw.
VENTURI – ORIFICE CONNECTION
-8 -
FLAME SETTING
For more information, visit www.desatech.com