Residential space heating appliances fired by wood pellets (104 pages)
Summary of Contents for Lincar Stella 740
Page 1
Residential space heating appliance with boiler fired by wood pellets Stella Siria Mod. 740 – 740/SA Mod. 840 - 840/SA USING – MAINTENANCE MANUAL Equipments built in conformity with European Standards for the marking and according to Art. 15a B-VG Cod.
mod. 740-740/SA–840-840/SA GB Dear Customer, While we thank you for the preference you granted us, we remind you to read carefully the present handbook because it gives You important warnings with particular attention to the installation, utilization, maintenance and to the security of the product in addition to condition of guarantee .
mod. 740-740/SA–840-840/SA GB INS TALLATION S ECTION DES TINATED TO THE INS TALLER Prescriptions and norms • Read carefully the contents of this handbook, it contains important information and instructions for installation, use, maintenance and product safety. • The installation, the electrical as well as the hydraulic connection, the working verification and the maintenance operations must be carried out by a qualified staff only, utilizing always the individual security devices and all other security features foreseen by local laws.
Page 4
In case of outlets of the thermal plant f luid, due to the intervention of the security valve, LINCAR S.p.A. declines any responsibility f or eventual damages to floors or what else had come in contact with the f luid.
mod. 740-740/SA–840-840/SA GB MEASURES FUME EXHAUST AND WATER TUB ES CONNECTIONS. • Should it be necessary to make holes on the wall for the fumes exhaust, you have to: − Measure and draw on the wall at natural size the points for the connection of the stove;...
mod. 740-740/SA–840-840/SA GB Preliminary operations • Take away the packing • Before installation, check the appliance integrity. In case of doubt, do not use the appliance and call the dealer. • P acking materials is for recycle, getting it in the specify container Appliance positioning •...
mod. 740-740/SA–840-840/SA GB ELECTRICAL CONNECTION • The appliance is equipped with an electrical cable having an European plug. It is a type “ Y” connection and therefore any replacement of the cable must be carried out by a qualified staff only. Feeding 1N 230V AC 50Hz. The electrical cable should be disposed in such a way to avoid any contact with hot and sharp parts.
Page 9
mod. 740-740/SA–840-840/SA GB − Internal round section, the square or rectangular section should have round corner with a ray not less than 20 mm − Internal section should be constant, free and indipendent − Rectangluar section with sides ration max of 1,5 −...
Page 10
mod. 740-740/SA–840-840/SA GB Inclination Roof Re Flux Area Highness Z ( m) C (°) 1,85 1,00 0,50 1,50 1,30 0,80 1,30 2,00 1,50 1,20 2,50 2,10 Re-flux Chimney pot area wind damping Chimney Revolving P ot Wind chimney pot for strong Damping horizontal wind...
Page 11
mod. 740-740/SA–840-840/SA GB CONNECTION TO A FLUE • It’ s advisable to read, follow and respect what indicated in the Section Installation. • Connect the heating equipment to the flue / chimney verifying that the exhaust pipe does not enter into the free section of the flue. •...
mod. 740-740/SA–840-840/SA GB NOTE :The installation room should not be put in depressure by other appliances such as suction hoods, chimneys, evacuation flues, present in the room itself or in the adjacent rooms, which are in communication. Technical data Stella Siria Description 740/SA...
• Any responsibility arising from an incorrect use of the appliance is totally at charge of the user and relieve LINCAR S.p.A. from all and any responsibilities. • The appliance must be installed and utilized only inside a room considered by the competent authorities suitable for installation and use.
mod. 740-740/SA–840-840/SA GB Fuel • The fuel to be utilized is GOO D Q UALITY WOO D PELLETS’ Calorific power kWh/kg 4,8÷5,2 Density kg/m Water contents Max 8% o f weight Ash percentage Max 1% of weight Diameter 5 ÷ 6,5 Lenght 20 ÷...
mod. 740-740/SA–840-840/SA GB • Be careful that no external corps, such as pieces of bag, wood pieces or other parts, that can obstruct the screw feeder and damage it, enter into the pellet tank • The load of pellet is done from the top, after having removed the cover. During stove functioning, it is advisable to employ the specific glove, because the stove surface could reach high temperature.
mod. 740-740/SA–840-840/SA GB Setting utilized only by appliances with domestic H O service - Inside of a menu it allows to run back the different menu and submenu. APPPLIANCE REGULATION (to be completely carried out before effecting the 1st Lighting) REGULATION of Heating water Temperature.
mod. 740-740/SA–840-840/SA GB - P ush on P 5 - Regulate the power of the appliance utilizing the buttons P 5 o P6 - Ter minate the regulation of the temperature of the water pressing shortly on button P4, the modification will be memorized and the display returns to the previous indication REGULATION of the Room Te mperature The setting of the room temperature means to put a limit to the heating process of the...
mod. 740-740/SA–840-840/SA GB - P ush P 4 and keep it pressed for few seconds until the display reports the start of the lighting NORMAL STARTING CYCLE P ush P4 and keep it pressed for few seconds The appliance begins an automatic cycle to effect the lighting, this cycle is composed by 3 phases, which are shown on the display : 1-START (duration approx.
mod. 740-740/SA–840-840/SA GB P roduction of warm domestic SANI Domestic warm water has been requested, appliance water WORK commute to max. power to reach the selected temp. (only mod. 740- Automatic Appliance carries out an automatic procedure to CLEANING cleaning cycle of eliminate part of residuals remained into the burner BASKET burner basket...
mod. 740-740/SA–840-840/SA GB -Mechanical security thermostat with manual resetting. This device is controlling the temperature of the water of the boiler, in case a too high temperature (90°C…95°C) is registered it stops immediately the feeding of fuel and a stop cycle starts, while on the display appears “...
Page 21
mod. 740-740/SA–840-840/SA GB • Menu 07 STATUS STOVE (shows the working status of the appliance). • Menu 08 PELLET CORRECT (correction of carburetion of the appliance). • Menu 9 SETTINGS TECHNIC (reserved to TECHNICIANS). MENU 01 (clock setting) Within this Menu you can adjust the time and the date of the electronic card, the set date and time will be utilized as reference for the activation of the switch ON/OFF programs.
mod. 740-740/SA–840-840/SA GB MENU 06 (load initial) Within this Menu you can set the continuous fuel load, this operation can only be effected when the appliance on the display is evidencing “ OFF”. This menu is utilized to fill the screw feeder when the appliance is new or in case of emptying of the pellet container.
Page 23
mod. 740-740/SA–840-840/SA GB day of week TUESDAY CLOCK HOURS hour of current time :38) CLOCK MINUTES minutes of current time (15: CLOCK DAY day of current date /05/2008) CLOCK MONTH month of current date (10/ /2008) CLOCK YEAR y ear of current date 2008 (10/05/ P ay attention to the value of parameters during setting up, because a wrong setting up will...
Page 25
mod. 740-740/SA–840-840/SA GB For a correct execution of the programs, set very carefully the data of Menu 01. Selecting oFF instead of the starting or extinction hour, the stove exclude the automatic starting or extinction Display Descriptio Example Range M-2-4 PROGRAM WEEK-END Activate(on)/ Deactivate(off) M-2-4-01...
mod. 740-740/SA–840-840/SA GB STATUS STOVE Shows informations about the working of the appliance Displayed values: Fume temperature, fume expeller motor rev/min, appliance status, room temperature, boiler pressure, time of fuel loading, and a screening of informations for TECHNICIANS. Menu 08 PELLET CORRECT - (Correction of appliance combustion). Display Description Example...
mod. 740-740/SA–840-840/SA GB Ashtray cleaning Open the lower door, take out the ashtray cover (to release the cover, turn the two lateral hooks), take the ashtray and empty it carefully, paying attention to possible hot combustion residuals, place the ashtray in its housing and closed the cover of the ashtray. DO NOT empty the ashes in inflammable containers, reme mber that into the ashes could be some embers, even after several hours from the extinction.
mod. 740-740/SA–840-840/SA GB We recommend to execute a regular maintenance of the appliance, of the f umes exhaust ducts and of the chimney. In case of a long time of non utilization of the appliance, before lighting the stove, verif y that f ume exhaust ducts and chimney are not obstructed. Accessories The following accessories are supplied with the stove : •...
mod. 740-740/SA–840-840/SA GB Appliance just started. Wait until the appliance has reached the normal working range. The heating plant The room temperature has reached the Set up a higher room temperature. (thermo siphon) is requested value. tepid The boiler temperature has reached Set up a higher boiler temperature.
mod. 740-740/SA–840-840/SA GB Noticed a too Breakdown/block plant Check circulation pump working. circulation pump. high temperature of Breakdown bulb security Verify/replace thermostat, verify the boiler Safety boiler temperature feeler wiring . (it is Thermal necessary to reset manually Air inside the boiler Eliminate air from the thermal plant.
Page 31
mod. 740-740/SA–840-840/SA GB A black-out has happened Empty and clean the burner basket Black-Out and then proceed with the lighting during the phase. regular working. EXAMPLES OF APPLIANCE/PLANT CONNECTION The following connection diagrams are only indications o f some connection possibilities and should not be considered as satisfaction in matter of installations.
740-740/SA–840-840/SA GB Technical data plate. You f ind here enclosed a copy of technical data plate. Lincar S.p.A. Via E. Fermi, 5 – 42046 Reggiolo (RE) – Italy – Tel. +39 0522 972260 – Fax +39 0522 973625 www.lincar.it info@lincar.it...