This section outlines the methods required to install and operate the OSD159 successfully. It should be
studied carefully if damage to the equipment or poor results are to be avoided.
This equipment has been fully tested prior to dispatch and is ready for immediate operation. However it
is advisable to check for external transportation damage before operation. If damage is evident, return
the unit with the packaging to your supplier immediately.
2.2
INSTALLATION
2.2.1
WARNING AND PRECAUTIONS
ELECTROMAGNETIC COMPATIBILITY
WARNING: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
OPTICAL OUTPUT OPERATION
Class 1
The multimode version of the OSD159 is a
Class 1 LED product. Wavelength of 850nm
and <-8dBm power output.
PRECAUTIONS
▲ All service personnel should be provided training as to the hazards of direct viewing of laser
radiation and of the precautionary measures during servicing of equipment
▲ Areas where laser products are installed should be restricted in access to trained service
personnel only and appropriate warning signs posted in the work area.
▲ All laser apertures should be covered by protective covers when not connected to optical
fibers. Never leave outputs uncovered.
▲ Laser equipment should be positioned above or below eye level where possible. Apertures
should be positioned away from personnel.
▲ Protective eyewear should be worn in the vicinity of laser equipment.
PAGE 8
OPTICAL SYSTEMS DESIGN
OSD159 OPERATOR MANUAL
Class 3A
The singlemode versions of the OSD159 are
Class 3A laser products.
1310nm
and
<+5dBm
wavelength of 1550nm and <+7dBm power
output.
Wavelength of
power
output
or