PRECAUTIONS
1.
Do not install the camera near electric or magnetic fields.
Install the camera away from TV/radio transmitters, magnets, electric motors, transformers and audio
speakers since the electromagnetic fields generated from these devices may distort the video image.
2.
Never disassemble the camera beyond the recommendations in this manual nor introduce
materials other than those recommended herein.
Improper disassembly or introduction of corrosive materials may result in equipment failure or other
damage.
3.
Try and avoid facing the camera toward the sun.
In some circumstances, direct sunlight may cause permanent damage to the sensor and/or internal
circuits.
4.
Keep the power cord away from water and other liquids and never touch the power cord with
wet hands.
Touching a wet power cord with the hands or touching the power cord with wet hands may result in
electric shock.
5.
Never install the camera in areas exposed to water, oil or gas.
Water, oil or gas may result in equipment failure, electric shock or, in extreme cases, fire.
6.
Cleaning
Use a damp soft cloth to remove any dirt from the camera body. Use lens tissue or a cotton tipped
applicator and ethanol to clean the camera lens. Please do not use complex solvents, corrosive or
abrasive agents for cleaning.
7.
Do not operate the camera beyond the specified temperature, humidity or power source ratings.
Use the camera at temperatures within -40℃ ~ 60℃ (-40℉~15.5℉) and humidity between
20~80%. The input power source is 12VDC.
Mobile IR Wedge Camera

Operation Instructions

EMW330/EMW330T
Model No.

Advertisement

loading

Summary of Contents for EverFocus EMW330

  • Page 1: Operation Instructions

    Mobile IR Wedge Camera Operation Instructions EMW330/EMW330T Model No. Please read this manual first for correct installation and operation. This manual should be retained for future reference. The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. PRODUCT OVERVIEW......................2 2. FEATURES..........................2 3. CONTENT LIST ........................2 4. SPECIFICATIONS ........................3 5. INSTALLATION ........................4 - 1 -...
  • Page 3: Product Overview

    1. PRODUCT OVERVIEW EMW330 has a streamline wedge type chassis which is suitable for transit/school bus mounting. EMW330 fixed lens model is equipped with dual-position lens and IR illuminator enabling user to adjust the best viewing angle. The dual-position IR illuminators provide clear images up to 50 feet away.
  • Page 4: Specifications

    4. SPECIFICATIONS EMW330 EMW330T 1/3'' SONY Super HAD CCD Pickup Device NTSC or PAL Video Format Scanning System NTSC: 525 TV lines, 60 fields/sec; PAL: 625 TV lines, 50 fields/sec. 768x494(NTSC)/752x582(PAL) Picture Elements 520TVL Horizontal Resolution 0.4 Lux / F=1.2(IR OFF) ; 0 Lux (IR ON)
  • Page 5: Installation

    5. INSTALLATION 1. Loosen 4 screws to separate camera’s base from its cover. 2. Detach light sensor wire from camera body. Light sensor wire - 4 -...
  • Page 6 3. Detach LED illuminator wire from camera body. LED illuminator wire 4. Loosen the screw to make Z-axis adjustment Loose the screw 5. Make Z-axis adjustment - 5 -...
  • Page 7 a) Loosen the 4 screws from fixe-lens bracket (or vari-focal lens bracket). Remove the fixe-lens bracket (or vari-focal lens bracket). b) Adjust the main board bracket right or left 90° , so that the lens can be positioned to the correct direction. c) Screw the lens bracket to the lens to fixe it.
  • Page 8 8. Loosen the 4 screws as shown in figure to detach IR LED panel and light sensor upper bracket from camera base. 9. Replace light sensor upper bracket by the light sensor front bracket. Loosen the 2 screws of light sensor upper bracket. - 7 -...
  • Page 9 10. Replace it by the light sensor front bracket and fixe it with the same screws. 11. Change position for IR LED panels by making them crossed. Using 4 screws to fixe the IR LEDs panel and light sensor front bracket to the camera base. - 8 -...
  • Page 10 1801 Highland Ave. Unit A 415 Oser Ave Unit S Duarte, CA 91010 ,U.S.A Hauppauge, NY 11788 Tel: +1-626-844-8888 Sales: +1-631-436-5070 Fax: +1-626-844-8838 Fax: +1-631-436-5027 Ihr EverFocus Produkt wurde entwickelt und Your EverFocus product designed hergestellt qualitativ hochwertigen manufactured with high quality materials and Materialien und Komponenten, die recycelt und components which can be recycled and reused.

This manual is also suitable for:

Emw330t