Download Print this page

Advertisement

OPERATORS
HANDBOOK
TASKMAN PRESSURE
WASHERS
TASKMAN
PO BOX 41
PLODDER LANE
BOLTON
LANCS
BL4 0LR
Tel: + 44 (0) 845 2304860
Fax: + 44 (0) 1204 854620
www.taskman-uk.co.uk
Issue 6 2013

Advertisement

loading

Summary of Contents for taskman Pressure Washer

  • Page 1 OPERATORS HANDBOOK TASKMAN PRESSURE WASHERS TASKMAN PO BOX 41 PLODDER LANE BOLTON LANCS BL4 0LR Tel: + 44 (0) 845 2304860 Fax: + 44 (0) 1204 854620 www.taskman-uk.co.uk Issue 6 2013...
  • Page 2: Table Of Contents

    CONTENTS Introduction Declaration of Conformity Identification Warranty Terms & Conditions Safe Working Operation Maintenance and Service Technical Information...
  • Page 3 PRIOR TO STARTING ENGINE TURN VALVE TO OPEN POSITION (FIGURE START ENGINE AS PER ENGINE MANUFACTURERS’ INSTRUCTIONS. ONCE UNITERRUPTED FLOW OF WATER IS OBSERVED, TURN VALVE TO CLOSED POSITION (FIGURE 2) PRESSURE WASHER IS THEN READY TO USE AS PER OWNERS’ MANUAL SUPPLIED WITH MACHINE. FIGURE 1 FIGURE 2...
  • Page 4: Introduction

    The contents of this Handbook although correct at the time of publication, may be subject to alteration by the manufacturers without notice. TASKMAN operate a policy of continuous product development. Therefore, some illustrations or text within this publication may differ from your machine.
  • Page 5: Declaration Of Conformity

    Seddons Plant & Engineers Limited DECLARATION CONFORMITY We: Seddons Plant & Engineers Limited, Of P.O. Box 41, Plodder Lane, Bolton, Lancs, England BL4 0LR declare that the following TASKMAN Pressure Washers:- Models:- PW100PH10/11/12, PW140PH12, PW150PH8/11/12/14, PW170PH13/15 PW170DY15, PW200PH13/15/21, PW200DY15, PW90PH12 Serial Numbers:- 1001-99000 To which this declaration relates, with a maximum net installed power of 6.5Kw.
  • Page 6 We guarantee under the provisions of the above Directive (2000/14/EC) that the Sound Power Levels for these equipment models will not exceed:- PW100PH10 104db PW100PH11 99db PW100PH12 104db PW140PH12 107db PW150PH8 104db PW150PH11 103db PW150PH12 107db PW150PH14 106db PW170PH13 106db PW170PH15 106db PW170DY15 114db PW200PH13 109db...
  • Page 7: Identification

    IDENTIFICATION PW90PH12 PW100PH11 PW140PH12 PW100PH12 PW140PH12T PW100PH10GC PW170PH15 PW150PH12GC PW200PH13 PW150PH14 PW200PH15 PW200DY15E PW200DY15ES PW200PH21...
  • Page 8: Warranty Terms & Conditions

    WARRANTY TERMS & CONDITIONS TASKMAN assures you that if any of the parts identified within the Parts section of this manual become defective due to faulty manufacture or materials within 12 months from the date of purchase, the part will be repaired or replaced under warranty free of charge by any authorised TASKMAN Distributor.
  • Page 9 WARRANTY TERMS & CONDITIONS are used to effect a repair, or if lubricants other than those recommended by TASKMAN and the engine manufacturers are used. The equipment must be serviced and maintained in accordance with the service schedules laid down in this handbook. Evidence that these have been complied with may be required before Warranty claims are reimbursed.
  • Page 10: Safe Working

    Engine Operators Handbook. Any modifications to the machine will affect its working parameters and reduce built in safety factors. Refer to TASKMAN before fitting any non-standard equipment or parts. TASKMAN accept no responsibility for any modifications made after the machine has left the factory, unless previously agreed in writing.
  • Page 11 SAFE WORKING Always be aware of the Lance Reaction Force when operating this machine. Always know how to stop the machine and bleed the water pressure quickly. Never over reach or stand on unstable supports, keep your footing and balance at all times. Never operate this machine from ladders or step ladders.
  • Page 12 SAFE WORKING Never smoke whilst filling the fuel tank, mop up any fuel spills immediately and in any event before running the engine and allow time for any vapours from the spilled fuel to disperse before starting the engine. Never run the engine in an enclosed or confined area, exhaust fumes in enclosed areas can kill.
  • Page 13 SAFE WORKING Many liquids used in this machine are harmful if taken internally or splashed into the eyes. In the event of accidentally swallowing oils or fuels, seek qualified medical assistance and advice. Always dispose of waste oils and fuels into designated waste oil storage tanks.
  • Page 14 SAFE WORKING ELECTRICAL STARTING SYSTEMS (Continued) Never remove any electrical cable while the battery is connected in the circuit. Only disconnect the battery with the engine stopped and all switches in the off position Always ensure that cables are fitted to their correct terminal, a short circuit or reversal of polarity will ruin diodes and transistors.
  • Page 15: Operation

    OPERATION Never commence work until the daily service checks have been carried out. WATER SUPPLY CONNECTION High speed pumps can be fed from mains water tap pressure (POSITIVE PRESSURE) or draw from a tank or sump via suction (NEGATIVE PRESSURE) however if used on suction (NEGATIVE PRESSURE) for prolonged periods premature seal wear is likely to result.
  • Page 16 OPERATION Never commence work until the daily service checks have been carried out. PRIMING THE WATER PUMP Each time the machine is put into operation the water pump will require priming before it will operate correctly. Priming the pump and hoses removes any air which may be trapped in the system and which may affect the correct operation of the pump and prevent the full working pressure from being reached.
  • Page 17 OPERATION Never commence work until the daily service checks have been carried out. LOW PRESSURE CHEMICAL APPLICATION The Low Pressure Chemical Application facility is an optional extra and may/may not be available on the machine. Totally immerse the filter on the chemical suction hose in the chemical solution container, connect the opposite end of the hose to the chemical induction on the water pump.
  • Page 18 OPERATION Never commence work until the daily service checks have been carried out. STARTING THE ENGINE Petrol Driven Units Read the engine operators manual before attempting to start the engine. Connect the inlet/suction hose to a suitable tap or completely immerse the inlet filter in the tank or sump.
  • Page 19 OPERATION gun is operated the EASYSTART valve will close and the water will stop discharging. Each time the trigger gun is closed water will discharge through the EASYSTART valve again. This is a built in safety feature of this unit to avoid overheating the pump and to ease starting.
  • Page 20 OPERATION To avoid damage to the water pump and gearbox (if fitted) never allow the diesel engine to run on idle/tick over speed for prolonged periods of time. MODEL PW200 ONLY As water enters the pump it will discharge through the EASYSTART valve in the pump to atmosphere, this is correct.
  • Page 21 MAINTENANCE AND SERVICE DAILY SERVICE CHECKS Read the engine operators manual for items in addition to those listed below. Check condition of suction and pressure hose and lance. Check suction filter, (if fitted) Check the fuel level. Check condition of air filter element, and clean replace as necessary.
  • Page 22 MAINTENANCE AND SERVICE Check all controls for correct operation. Report any faults or missing equipment or damage immediately. WEEKLY SERVICE CHECKS Read the engine operators manual for items in addition to those listed below. All the daily service checks plus check condition of water filter and clean as necessary, the water filter is normally located in the water inlet port of the pressure relief valve, see page 20 to identify the type of filter installed.
  • Page 23 MAINTENANCE AND SERVICE INLET FILTERS-IDENTIFICATION CLEAN OR REPLACE INLET FILTERS FREQUENTLY Filter Type A Filter Type B...
  • Page 24: Maintenance And Service

    MAINTENANCE AND SERVICE FAULT CAUSE REMEDY Inlet Filter blocked or dirty Check & Clean Inlet Filter Pump sucking air Check water supply & Pump running normally but possibility of air ingress. pressure low on installation Valves sticking Check & clean or replace. Unloader valve seat faulty Check &...
  • Page 25: Technical Information

    TECHNICAL INFORMATION Pressure Flow Gearbox Pump Weight Dimensions Model Engine Psi/Bar Ltr/min Type Type (Kg) HxWxL(mm) Honda Petrol 440x340x520 W1210 1350/90 GX120 PW90PH12 Honda 1500/100 Petrol WW909 1500/100 WW909 GX120 470x410x540 PW100PH11 2250/150 GX160 TT1508 GX160 PW100PH12 PW150PH8 Honda 2000/140 Petrol W140 510x450x600...
  • Page 26 TECHNICAL INFORMATION Yanmar Diesel 3000/200 WS201 850x600x100 L100 PW200DY15ES...
  • Page 27 TECHNICAL INFORMATION LUBRICANTS Water Pumps SAE10W/30 Engine oil Gearbox SAE90 Gear Oil Engines Yanmar L100 Diesel:- 10W30 or 20W40 API Classification CD Honda Petrol Engines :- 10W30, 10W40, 15W40 API Classification SF or SH...
  • Page 28 CALIFORNIA Proposition 65 Warning Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects and other reproductive harm...