Download Print this page

User Controls - RDT RM96xx User Manual

Advertisement

User Controls

Factory Settings
The RM96xx is shipped from the factory pre-pro-
grammed to operate with the following settings:-
Serial Port
Mode
Listen Before Tx
Serial Port
Baud Rate
Parity
Data Bits
Stop Bits
RF Parameters
RF Channel
Power Level
Address
RF Data Rate
LED FUNCTIONS (Run Mode)
D10 Carrier Detect
D11 Buffer Full
D12 Receive Serial Data
D13 Transmit Serial Data
D14 RF Receive
D15 RF Transmit
D16 Supply Voltage
D17 Supply Voltage
LED FUNCTIONS (All Modes)
Red=LOW (< -5v)
Green=HIGH (> +5v)
D1 CTS (input to RM9600)
D2 DSR (input to RM9600)
D3 DCD (output from RM9600)
D4 RxD
(input to RM9600)
D5 TxD
(output from RM9600)
D6 DTR (output from RM9600)
D7 Spare (reserved)
D8 RTS (output from RM9600)
FIG. 2 RM96xx Radio Modem Board Layout
Async, FEC On
ON
RS232
9600
None
8
1
1
500mW
0
16K
SW2
User Configuration
Settings are altered by following 3 simple steps:-
1.
Adjust Rotary switch (SW2) for desired
function (see table 1)
2.
Select required parameters using DIL
switch (SW1)
3.
Press 'STORE' button (SW3)
The above steps may be repeated for each Rotary
Switch function indicated in the table on page 14.
(refer to notes for exceptions to this rule)
To ease configuration, LED indicators D10-D17
display the current stored DIL switch settings for
each rotary switch function, excluding functions '0'
and '1'.
99 mm
4 x Mounting holes are M3 (3mm)
D10
D17
ON
SW3
1 2 3 4 5 6 7 8
SW1
UHF Synthesised
FM Transceiver
Type IRDN031/0
Frequency Range
406 to 470 MHz
ERP
500 mW max.
Made in England
Radio Data Technology Ltd
D1
RS485
109 mm
13
D8
DC
RS232
Supply

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Rm96 series