Ideal Air 700500 Installation & Operation Manual

15 seer mini-split air conditioner heat-pump
Table of Contents

Advertisement

15 SEER MINI-SPLIT AIR CONDITIONER HEAT-PUMP
MODEL: 700500
700505
700510
Installation VIDEO AVAILABLE ON www.ideal-air.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 700500 and is the answer not in the manual?

Questions and answers

Jeremy Beddingfield
August 9, 2025

How to dismantle the indoor unit to take the fan out

User image 689732f1d7f56

Summary of Contents for Ideal Air 700500

  • Page 1 15 SEER MINI-SPLIT AIR CONDITIONER HEAT-PUMP MODEL: 700500 700505 700510 INSTALLATION VIDEO AVAILABLE ON www.ideal-air.com...
  • Page 2 vide snow vents. When Connecting Refrigerant Tubing Tighten the nut with a torque wrench for a leak free connection. Open the stop valves all the way and leave open. Check for leaks with soapy water at all refrigerant line connections. NOTE: Depending on the system t...
  • Page 3 Serrer l'écrou avec une clé dynamométrique pour une connexion sans fuite. Ouvrir les vannes d'arrêt tout le chemin et laisser ouverte. Vérifiez pour les les fuites avec la l 'eau savonneuse à tous les connexions de ligne de de fluide frigorigène.
  • Page 4 T o o l n am e C o n t e n t s o f c h a n g e Pr e s s u r e is h ig h an d c an n o t b e m e a s u re d w it h a c o n v en t io n a l ga u g e. T o p r e v e nt er r o ne o u s m ix in g o f ot he r r e fr ig er a n ts , th e d ia m et er of e a c h p o rt h a s b e en c ha n g ed .I t G a u g e m a n if o ld is r e c o m m en d e d th e g au g e w ith s ea ls - 0 .1 t o 5.
  • Page 5 e system before beginning. Installation Accessories Nam e Q’ty Table 4 Cooling/Dry Mode Heating Mode For indoor unit Wall hook bracket Outdoor temperature -10C(14F)~52C(125F) -23C(-10F)~23C(75F) installation Indoor temperature 16C(60F)~30C(90F) 10C(50F)~30C(90F) Use for air conditioner Rem ote controller operation Indoor humidity Battery For rem ote control unit For indoor unit...
  • Page 7 120V,60HZ...
  • Page 11 Remove the waterproofing covers on the outdoor unit quick connectors. Inspect both quick connectors on outdoor unit and lineset for debri, clean if necessary. If debri is allowed to enter system, damage may occur. Connect the quick connect fittings to the outdoor unit valves with 2 wrenches. DO NOT OVER TIGHTEN, DAMAGE &...
  • Page 12 1. Start the A/C, operate in Cooling mode. 2. Remove the cap of the two valves with a wrench. 5. Disconnect the power cable from outdoor unit. 6. Loose the nut of the quick connect pipe from the outdoor unit valve with 2 wrenches INSURE NO DEBRI ENTERS THE QUICK CONNECTS.
  • Page 13 12000Btu/h Electrical Wiring Diagram Outdoor Unit(120V/60HZ) Blue Black Inverter modular White COMPRESSOR CN614 SENSOR (-) CN27 (+) SENSOR PIPE Main PCB SENSOR CN15 Black EXHT CBB65 Reactor Capacitor Blue Blue CN21 (+) Valve (-) CN10 Black Black CN14 Yellow Motor Brown White CN17...
  • Page 14 18000Btu/h Electrical Wiring Diagram Inverter modular Yellow Black Brown PT RT PG LINE TRANS IN CN11 L-IN T2-PIPE T1-ROOM CN15 CN17 WHITE WHITE TRANS OUT BLACK BLACK DISPLAY BOARD TRANSFORMER...
  • Page 15 24000Btu/h Electrical Wiring Diagram Blue Black White COMPRESSOR Inverter modular CN614 SENSSOR CN27 SENSSOR PIPE SENSSOR CN15 EXHT Main PCB Reactor CBB65 Capacitor CN21 Blue Blue Valve CN10 White CN14 Black Black Motor Orange Blue CN17 CBB61 Capacitor (AC) (AC) Rectifier bridge (AC) CN11...
  • Page 16 36000Btu/h Electrical Wiring Diagram CN614 Inverter modular White COMPRESSOR Black Blue PFC INDUCTANCE N( - ) SENSSOR CN27 IN-L P5-N P( +) SENSSOR PIPE P2-P OUT P6 P1 SENSSOR CN15 P3-L Main PCB EXHT P4-N OUT BOARD BLUE Blue CN21 Blue Valve CN10...
  • Page 17 INDOOR PCB & OUTDOOR MAIN PCB & INVERTER MODULAR PCB 36KBTU Outdoor Inverter Modular PCB 12K/18K/24/36KBTU Outdoor Main PCB 24KBTU Indoor PCB 12K/18K/24K Outdoor Inverter Modular PCB 12K/18KBTU Indoor PCB 36KBTU Indoor PCB...
  • Page 18 120v/60hz power 12kbtu 230v/60hz power 24kbtu 36kbtu (3 ) A lw a y s f a s te n th e o u ts id e c o v e r ing o f th e (1 ) M a tc h th e te r m in al blo c k n um b e r s a n d c o nn e c t io n c o r d w ith t h e c o rd c lam p.
  • Page 19 120V/60HZ 230V/60HZ 12KBTU 24KBTU/36KBTU Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc. ). Every wire must be connected firmly. No wire should be allowed to touch refrigerant tubing, the compressor or any moving part.
  • Page 23 9-core signal wires Remote controller filter Air intake grill Carbon filter Photo catalyzer filter Front cover louver Drain hose Power cable with plug Step motor Air deflector assembly Liquid quick connector Gas quick connector evaporator Motor bearing right Motor buffer right Blower motor Motor bearing left Motor buffer left...
  • Page 24 NAME Q'TY NAME Q'TY Top panel Gas valve Back grill Liquid valve Outdoor fan Capillary Condenser Rev valve coil Handle Side panel Front grill Access plate Front panel Capacitor clips Bottom plate Compressor capacitor filter capacitor Wire clip Partition board Electric box Reactor Fan motor capacitor...
  • Page 25: Remote Controller

    Remote Controller LCD Display Temperature UP/DOWN TEMP TEMP ON/OFF Fan Speed Button SWING SWING Swing Button Time Setting Button Mode Button Sleep Mode Button MODE SLEEP Clock Set Button Setting Button CLOCK TIMER SWING C/ F SWING Air Direction Button RESET RESET BUTTERY...
  • Page 26 Timer Operation (Timer-on/Timer-off) Setting the Timer-on You can set the timer-on or timer-off before you sleep Press TIMER button when the unit is running or go home. to set the timer-on. Press button to set the Hr./Min. Press once, the hour will change with 1 hour, the minute will change with 10 minutes.
  • Page 27 Swing Operation ( Vertical Air Direction Adjustment) Please set the following operation while the air-conditioner is running. To start the auto swing operation. Press SWING button. To cancel the auto swing operation. TEMP Please press SWING button again. ON/OFF SWING The auto-swing operation will be cancelled if the SWING button is pressed.
  • Page 28 Sleep Operation Please set the following operation while the air-conditioner is running. Please set this function when you want a quiet environment to rest. To start sleep operation: Press SLEEP button, there will have on the remote controller To cancel sleep operation: Press SLEEP button again.
  • Page 29 Fan Speed and Air Flow Direction Adjustment Please press FAN to change the fan speed. When pressed once, the fan speed will be Select the fan speed and changed in the following sequence: air direction you like. (Low) (Mid) (High) (Auto) Please set the fan speed to high speed if you want to cool down the whole room quickly.
  • Page 30 Select the Mode (Cooling-Dehumidifying-Heating-Ventilation) Select”Auto-Ccooling-Dehumidifying-Heating” press ON/OFF button. Select the mode, and you can adjust the temp. or air direction. Please MODE to select the running mode. Press once, the mode change as the sequence: Auto - Cooling - Dehumidifying - Heating (only for heating pump type) - Ventilation.
  • Page 31 TEMP SWING MODE SLEEP CLOCK TIMER SWING SWING C/ F TEMP SWING MODE SLEEP CLOCK TIMER SWING C/ F SWING...
  • Page 35: Error Codes

    Troubleshooting Guide On indoor unit central dis play: ERROR ERROR CODE TROUBLE SHOOTING CODE INDICATION A. Check the voltage of input AC power is within normal range. B. Check DC power voltage on outdoor unit main OVER CURRENT OR PCB, if the voltage is lower than 150VDC, then replace the LOW CURRENT outdoor unit main PCB;...
  • Page 36 Troubleshooting Guide A. Check if indoor unit fan motor is operating; ANT I-FROSTING IN B. Check if unit is in the cooling mode when ambient COOLING temperature is too low; or is in the heating mode when MODE,ANT I-OVERHE ambient temperature is too hot; C. Check if the resistance ATING IN HEAT ING data of indoor unit fan coil temperature sensor is correct MODE...
  • Page 37 Troubleshooting Guide A. Connection location on outdoor unit main PCB is: CN15 PO\PG\PQ for 12kbtu/18kbtu/ 24kbtu/36kbtu, PO is for OUTDOOR UNIT outdoor ambient temperature sensor, PG is for outdoor fan AMBIENT coil temperature sensor, PQ is for outdoor unit discharge TEMPERATURE gas temperature sensor.
  • Page 38 Troubleshooting Guide On outdoor unit main PCB there are 4 LED lamps, one for power supply and 3 for operational status indication and/or ERROR CODE display. Outdoor unit LED lamps display and error code indication: LED lamp for power supply is lit when system power is supplied. LED lamps’...
  • Page 40 ambient/Indoor/outdoor pipe sensor resistance ambient/Indoor/outdoor pipe sensor...
  • Page 41: Indoor Unit

    WIRING FOR AUXILIARY THERMOSTAT Indoor Unit Yellow White cable connector connector Thermostat White Black cable Black...

This manual is also suitable for:

700505700510

Table of Contents