Water Quality - Bosch GWH 345 ESR-N Manual

Temperature modulated with electronic ignition suitable for heating recirculating potable water
Table of Contents

Advertisement

Pressure drop curves
Note: Flow above 5 GPM is not permitted.
50 feet of head
40 feet of head
30 feet of head
20 feet of head
10 feet of head
0 feet of head
Fig. 9
GWH 345 ESR
50 feet of head
40 feet of head
30 feet of head
20 feet of head
10 feet of head
0 feet of head
Fig. 10 GWH 450 ESR
2.7

Water quality

Water quality can have an impact on appliance performance and appliance longevity, and may not be covered by the
manufacturer's warranty.
For water analysis data call your local water department. If on a well system, have well water analyzed periodically. If
water quality is exceeding one or more of the values specified below, Bosch recommends installing a water condi-
tioner or softener.
Descri-
pH
TDS
ption
(Total
Dissolved
Solids)
Max.
pH
mg/l or
Levels
range
ppm
6.5-8.5
500
Table 2 Water Quality Specifications
6 720 607 909
GWH 345 ESR
0 GPM
1 GPM
2 GPM
GWH 450 ESR
0 GPM
1 GPM
2 GPM
Total
Aluminum
hardness
mg/l or
mg/l or
ppm
ppm
100 (6
0.2
grains)
3 GPM
4 GPM
water flow rate
3 GPM
4 GPM
water flow rate
Chlorides
Copper
mg/l or
mg/l or
ppm
ppm
250
1.0
Appliance details
5 GPM
6 GPM
5 GPM
6 GPM
Iron
Manganese
Zinc
mg/l or
mg/l or ppm
mg/l or
ppm
ppm
0.3
0.05
5.0
9

Hide quick links:

Advertisement

Table of Contents
loading