Installation - Desa LGCFTP Owner's Operation And Installation Manual

Vent-free compact fireplace
Table of Contents

Advertisement

AIR FOR COMbUSTION AND VENTILATION
Vent lation
Grills into
Or
Adjoining
Remove
Room,
Door into
Option 1
Adjoining
Room,
Option 3
12"
Figure 6 - Ventilation Air from Inside
Building Shown with Optional Mantel
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
and one within 12" of the floor. Connect these
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system's circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install fire-
place. Follow all local codes.
Note: Your fireplace is designed to be used in
zero clearance installations. Wall or framing
119508-01B
12"
Ventilation Grills
Into Adjoining Room,
Option 2

INSTALLATION

www.desatech.com
Continued
items directly to the outdoors or spaces open
to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation for required size
of ventilation grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.
Outlet
Air
Inlet
Air
Figure 7 - Ventilation Air from Outdoors
Shown with Optional Mantel
material can be placed directly against any ex-
terior surface of your fireplace, except where
standoff spacers are integrally attached. If
standoff spacers are attached to your fire-
place, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough openings
to create the easiest installation (see Built-In
Fireplace Installation, page 11).
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your unit. If your gas supply is not
correct, do not install fireplace. Call dealer
where you bought fireplace for proper type
fireplace.
WARNING: This appliance is
equipped for either natural gas
or propane/LP gas but not both.
Gas type is indicated on the rat-
ing plate. Field conversion is not
permitted.
Ventilated
Outlet
Attic
Air
Ventilated
Inlet Air
Crawl Space
To Attic
To
Crawl
Space
9