Saturn WARRANTY SERVICE: Please read warranty information first ™ If after reviewing the troubleshooting tips the unit will still not work, you should return it to the • Warnings & Cautions Dealer where you purchased it. They may be able to further evaluate the unit and test its various components and quite possibly will be able to identify and/or fix any problems. If the Dealer is • Saturn Day/Night Temperature, Humidity & CO2 Integration Controller Overview ™ unable to fix the unit, they will return it to us for factory repair. • Instructions for Operation If there are no Dealers in your area, you may contact us directly for technical support. If we • Troubleshooting Tips cannot help you resolve the problem over the phone, we will issue you a Return Merchandise Authorization (RMA) number authorizing you to return the unit to us for factory reconditioning • Controller Specifications (if the controller is currently under warranty). Contact the number below for a RMA number and • Installation Example shipping address. Please complete the form below and include it with your unit, and write the • Warranty Information RMA number clearly on the outside of the box.
Warranty Information controller leaves the ‘CO2 OUTLET’ active until the temperature set point is exceeded. When this occurs, the ‘CO2 OUTLET’ is deactivated and then the ‘FAN OUTLET’ is activated; and • Titan Controls warrants the original purchase of this product against defects in material your exhaust fan will run until the temperature is lower than your preferred setting. After ® the temperature has lowered below the selected temperature level the ‘FAN OUTLET’ is and workmanship under normal use for three (3) years from the date of purchase. defeated and the ‘CO2 OUTLET’ is activated and can begin dosing your garden with CO2 • During the warranty period, Titan Controls will, at our option, and without charge, repair or ® again, if required. This innovative function serves two purposes: One, this allows maximum replace this product if the controller or any of its components fail or malfunction. CO2 coverage with minimum CO2 waste; Two, your exhaust fan is working only when it is required - saving power and wear & tear on your gear. At any time if the humidity set point is • All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) exceeded, the controller will activate the ‘HUMIDITY OUTLET’ and reduce the humidity level number prior to any service of the product. to below your preferred humidity setting. During the nighttime hours the controller defeats • This warranty is in lieu of all other warranties, expressed or implied, including the warranties the ‘CO2 OUTLET’ (No need for CO2 at night) and activates the ‘NIGHT OUTLET’. The of merchantability and fitness for use, and of all other obligations or liabilities on the part of ‘NIGHT OUTLET’ may be used to operate a circulation fan, CO2 exhaust fan using a short the seller. cycle timer, garden maintenance night light or any other device that you would like only to run during the nighttime hours. If during the nighttime hours the temperature exceeds your • This warranty shall not apply to this product or any part thereof which had been damaged preferred setting, then the ‘FAN OUTLET’ is activated to lower the temperature to desired by accident, abuse, misuse, modification, negligence, alteration or misapplication. levels. If the humidity set point is exceeded during the nighttime hours, then the ‘HUMIDITY • Controllers with serial numbers or date tags that have been removed, altered or obliterated; OUTLET” is activated and will lower the gardens humidity to desired levels. This provides broken seals that show evidence of tampering; mismatched board serial numbers or the grower with 24 hour temperature and humidity control. The Saturn 2 is built with the ™ nonconforming parts, are excluded from coverage. highest quality components to provide the user with years of trouble free service. Controllers created for our industry, by our industry! • Titan Controls...
Installation Example • Finally, plug the Saturn 2 into a dedicated 120 Volt – 15 Amp power source. ™ • Use of a surge protection device is recommended to protect your Saturn 2 from potential ™ power damage in areas where this may be an issue. • Your Saturn 2 will now control your equipment at the desired settings. ™ Troubleshooting Tips If the Saturn 2 is not performing as expected, try the following: ™ a. Confirm that your power input source is active by using a voltage test meter, and verify that the power input source is providing 120 Volts of power to the Saturn ™ b. Validate that the power outlets of the Saturn 2 are active by setting the temperature ™ and humidity dials to the lowest settings. Then use a voltage test meter to verify power is flowing through the controller to the power outlets. c. Ensure that the exhaust fan and dehumidifier are ‘ON’ and set to the lowest temperature and humidity levels. d. Verify that the Saturn 2 is set at the proper temperature and humidity levels to activate ™ and deactivate equipment. e. If your ventilation or dehumidification equipment does not turn off, verify that your exhaust fan and dehumidifier are the correct size for your grow area. Increase size of exhaust fan or dehumidifier (if necessary) to cool and dehumidify the garden as quickly as possible. f. If you are still having problems with your Saturn 2, please contact our Technical Service ™...
Need help?
Do you have a question about the Saturn 2 and is the answer not in the manual?
Questions and answers