Aquamarine Water Treatment BBUV 2700 Operation And Maintenance Manual

Filtration & uv system

Advertisement

Quick Links

FILTRATION & UV
SYSTEM
Operation and

Maintenance Manual

Model
BBUV 2700
BBBUV 2700
Aquamarine Water Treatment |122 Capricorn Drive | Capricorn Park | Muizenberg | Cape Town |South Africa
Tel. 021 788 53 41 | Fax 021 788 53 86 |
www.aquamarinewater.co.za

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BBUV 2700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aquamarine Water Treatment BBUV 2700

  • Page 1: Maintenance Manual

    FILTRATION & UV SYSTEM Operation and Maintenance Manual Model BBUV 2700 BBBUV 2700 Aquamarine Water Treatment |122 Capricorn Drive | Capricorn Park | Muizenberg | Cape Town |South Africa Tel. 021 788 53 41 | Fax 021 788 53 86 | www.aquamarinewater.co.za...
  • Page 2: Table Of Contents

    Filtration & UV System Operation and Maintenance Manual Table of Content Introduction ............................3 Safety Precautions ..........................3 General ..............................3 Safety headings ............................. 3 Labeling ..............................4 Specifications ............................4 System Specifications ........................... 4 4.1.1 Size and Weight ............................ 4 4.1.2 Filtration ..............................
  • Page 3: Introduction

    If your system is altered at the site of operation, or if the feed water conditions change, please con- tact Aquamarine Water Treatment on +27 (0) 21 788 53 41 All rights regarding the design and configuration of this system may not be copied or passed on to a third party without permission from Aquamarine Water Treatment.
  • Page 4: Labeling

    Filtration & UV System Operation and Maintenance Manual Labeling Do not remove any warning labels or system labels or direction arrows from the plant as they identify flows and warn against potential hazards. Specifications System Specifications 4.1.1 Size and Weight Length 1050 mm Width...
  • Page 5: System Description

    The warning lights will glow permanently when the unit is on line , if a warning light goes out , this indicates a lamp failure , ballast failure or starter failure. Contact Aquamarine Water Treatment c.c for replacement parts (see spare parts at the end). The U.V tubes should be replaced every 8000 hrs or at least once a year.
  • Page 6: Uv System

    Filtration & UV System Operation and Maintenance Manual UV System 7.4.1 General Function The system is on and in operation when the power is switched on and the green light on the ballast (9) is illuminated. A problematic bulb will be indicated by the red light on the ballast (9) illuminating and by a buzzing sound being emitted from the ballast (9).
  • Page 7: Maintenance

    UV System The U.V lamp should be changes every 8000 hrs or at least once a year. Contact Aquamarine Water Treatment c.c for replacement parts (see spare parts at the end). Caution: Ultra Violet light can cause severe eye problems, blindness or skin problems similar to extreme sun burn.
  • Page 8: Troubleshooting

    Filtration & UV System Operation and Maintenance Manual Troubleshooting Should you have a problem with a Filtration & UV System please contact one of the following people at Aquamarine Water Treatment.  Wade Bills (Engineering, Sales)  Lee Hodgins (Engineering, Sales) ...