Download Print this page

Interface Connections - Vivotek AE-235 Installation Manual

Infrared illuminator enclosure

Advertisement

AC input wiring: connect power lines to an external power cord.
Power cords
III

Interface Connections

DC 12V
You should check the DI and Do settings on a web console in Configuration > Applications > DI and
DO. For example, if you connect the Red line to the DI, its normal status should be High.
Connector Block
DI
Ground
Brown: Line
Yellow/Green: Earth
Blue: Neutral
Once a camera is installed, you can connect
the 12V DC phone jack connector to power the
camera.
Since the housing comes with a light sensor,
which controls when to turn into the night mode
and light the IR LEDs. Connect the red or orange
wire to the DI pin on the terminal block, and the
black wire to the Ground pin.
The following determines which wire (Red or
Orange) should be connected to the DI pin.
Red: If IR trigger signal is on the high position (+5V
DC), connect the Red and Black wires.
Orange: If IR trigger signal is on the Low position
(+0V DC), connect the Orange and Black wires.