DER EE DE-33 Instruction Manual

K-type wireless thermometer

Advertisement

Quick Links

HCA003300-00020R
Instruction Manual
K-Type Wireless Thermometer
Thanks for purchasing K-type Wireless Thermometer DE-33.
Please read the operation manual carefully before using and
keep it properly for contingent use and reference. Thanks!
ELECTRICAL INSTRUMENT CO., LTD.
7F-2, NO.351, SEC.2, CHUNG SHAN ROAD.,
CHUNG HO CITY, TAIPEI HSIEN, TAIWAN
TEL : 886-2-2226-6789(REP.) FAX : 886-2-2226-7979
E-mail: deree@ms21.hinet.net
http://www.deree.com.tw
Model No. DE-33

Advertisement

Table of Contents
loading

Summary of Contents for DER EE DE-33

  • Page 1 Model No. DE-33 Instruction Manual K-Type Wireless Thermometer Thanks for purchasing K-type Wireless Thermometer DE-33. Please read the operation manual carefully before using and keep it properly for contingent use and reference. Thanks! ELECTRICAL INSTRUMENT CO., LTD. 7F-2, NO.351, SEC.2, CHUNG SHAN ROAD., CHUNG HO CITY, TAIPEI HSIEN, TAIWAN TEL : 886-2-2226-6789(REP.) FAX : 886-2-2226-7979...
  • Page 2: Table Of Contents

    Catalogue Ⅰ. Features ......... . . 01~02 Ⅱ.
  • Page 3: Ⅰ. Features

    Ⅰ. Features ● Sensor unit is equipped with 2 thermocouples to detecting the temperature change of environment, water or soil at the same ● Main unit with big LCD display and easy for read. time. ● Simultaneous display 2 sets of temperature measured ●...
  • Page 4: Ⅱ. Introduction Of Main Unit And Sensor Unit

    Ⅱ. Introduction of main unit and sensor unit a. Connect RS-232 cable to link with PC and recording RS-232 socket the temperature change and form in graphic. ④ (equipped PC use (A) Main unit – appearance and functions b. Refer to Help in PC software operation for relevant RS-232 adaptor operation.
  • Page 5: (C) Sensor Unit - Appearance And Placing

    Recording symbol to indicate 24 records of temperature change at ⑰ 4. Do not put sensor unit into fridge or the metallic sealed CH2 in past 12 hours. equipment (enclosure) directly for measurement. Because the ⑱ Indicate temperature range set at HI or LO at CH1 & CH2 signal of sensor unit is blocked and can't transmit to main unit ⑲...
  • Page 6: Ⅲ. Power On Process

    Ⅲ. Power on process Demonstration of measurement (A). Battery installation Always install main unit first and then sensor unit. Follow water temperature instruction of A & B as below to enable transmitting and of aquarium WIRELESS THERMOMETER receiving in good work. TRANSMITTER 1.
  • Page 7: (B). Set Up I.d. (Identity Code)

    2. Once batteries are installed the full segment will display on LCD B. Battery installation of sensor unit for 2 seconds. Follow the steps from dwg#1 to dwg# 7 to complete the installation. CH1 temperature (1) Loose 2 screws on battery door with Philips screw driver. (2) Do not attempt to loose 4 crews marked on dwg#2.
  • Page 8: (C). Set Up Time (Clock)

    Attention: Do not attempt to loose the screws marked. (C). Set up time (clock) After power on must set up clock immediately enable to work dwg#1 dwg#2 with the relevant functions 1. Hold MODE key for 3 seconds to access time set function as dwg#2.
  • Page 9: Ⅳ. Application Of Thermometer

    Ⅳ. Application of thermometer 《ATTENTION》 a. Time set can only operate in simple measuring mode as (A) Key function: dwg#1. In MAX/MIN, LGR or alarm mode can't operate time set as dwg.#6. MODE key shift 4 modes display b. In case, accidentally push MAX/MIN key MAX, MIN symbol 1.
  • Page 10: (B) Measurement Of Temperature

    (1) CH1 & CH2 temperature display ( C) ° (B) Measurement of temperature a. Change display to the simple measuring mode as dwg#1 below. Hold MODE key simple measuring b. Upper layer display of CH1 is for the temperature >3 seconds mode display measured by the thermocouple at A socket.
  • Page 11: (C). Set Up Alarm Function

    (C) Set up alarm function ( e. Set HI or LO temperature: (1) Set up temperature alarm of CH1 and CH2: in condition ● Only one option to set alarm range at HI or LO of the temperature reaches and higher beyong ( ≧HI ) temperature.
  • Page 12: (D). Read Temperature Record

    (D) Read temperature record (LGR CALL) f. Activate alarm function ( display): (1) 12 hours auto data logging for CH1 and CH2 ● Push MODE key to switch dwg#1 to dwg#2 temperature corresponds with real time record. Recording is every 30 minutes with 24 sets maximum. Once capacity is full will start over the recording cycle CH1 temperature from the beginning and the old record will be replaced.
  • Page 13: (E) Search Temperature Of Sensor Unit

    (F) MAX / MIN temperature (E) Search temperature of sensor unit (1) Push SEARCH key for manual search of signal from (1) Maximum / Minimum temperature recording function sensor unit. Every search is lasting 5 minutes. If 5 (set clock before entering MAX/MIN mode). Set minutest search is failed the radius symbol ( MAX/MIN mode starting from dwg#1.
  • Page 14: (G) Low Battery Symbol Of Main Unit And Sensor Unit

    (H) Trouble shooting of main unit (1) Either in MAX/MIN mode, alarm mode or reading temperature record (LGR) mode, can't operate push MAX/MIN key push MAX/MIN key temperate range alarm setting or clock set. All functions only enable at the simple measuring mode. (as below drawing status 1 ~ 3) dwg#5 dwg#6...
  • Page 15: (I) Function Table

    Ⅴ. Specification of main unit and sensor unit (I) Function table Function Key Operation Dwg#1 Initial setting of simple measuring mode to check CH1 & CH2 WIRELESS THERMOMETER current temperature. To set dwg#2~6 must go back to CH1 & CH2 DE -3 3R K-Type WIR ELE SS THE RMOMETE R TRANSMITTER...
  • Page 16 Attention (6) Accuracy (23 °C ± 5°C, 80% R.H. MAX. The repeated sharp flexing can break the thermocouple Type Measurement Resolution Accuracy leads. To prolong lead lifetime, avoid sharp bend in the Ranges(°C) (°C) (%rdg+°C) leads, especially for the cable relief to connector. ±(0.5+1) -199.9~0.0 ±(0.2+0.5)

Table of Contents