PROGRAM SCAN

You can limit the scanning frequency range. There
are 10 memory channel pairs (L0/U0 ~ L9/U9)
available for specifying the start and end frequencies.
It monitors the range between the start and end
frequencies that you have stored in memory channels
L0/U0 to L9/U9. Before performing the Program
Scan, store the Program Scan frequency range to
one of the memory channel pairs L0/U0 ~ L9/U9.

Storing Program Scan Frequency Range

1 Press [VFO].
2 Press [BAND] to select your desired band.
3 Turn the Tuning control or press [ ]/ [ ] to
select your desired start frequency.
4 Press [F], then turn the Tuning control or press
[ ]/ [ ] to select a memory channel from L0 ~
L9.
5 Press [MR] ([ ] or [MNU]) to store the start
frequency in the memory channel.
6 Turn the Tuning control or press [ ]/ [ ] to
select your desired end frequency.
7 Press [F], then Turn the Tuning control or
press [ ]/ [ ] to select the corresponding
channel from U0 ~ U9 (you must select the
same numeric value as in step 4).
For example, if you selected L0 in step 4,
you must select U0 in this step.
8 Press [MR] ([ ] or [MNU]) to store the end
frequency in the memory channel.

Performing the Program Scan

1 Press [VFO].
2 Turn the Tuning control or press [ ]/ [ ] to
select a frequency within the frequency range
of memory channel L0/U0 ~ L9/U9.
3 Press [VFO] (1 s) to start the Program Scan.
4 To stop the Program Scan, press [VFO] or
[PTT].
Note:
If you press [MONI], Program Scan temporarily pauses.
Release [MONI] to resume scanning.
If the Fine Tuning function is ON, the scanning does not stop
at the busy channels.
The transceiver stops scanning in all modes when it detects
a signal.
If more than 2 Program Scan channel pairs are stored and
overlaps the frequency range among the pairs, the smaller
Program Scan memory channel number has the priority.
To perform the Program Scan, the following conditions must
be met. Otherwise, the Band scan starts {page 22}.
• The upper and lower limit frequencies are in the same
frequency band.
• Ln < Un (where "n" is the Program Scan channel number).

MHz SCAN

MHz Scan allows you to scan an entire 1 MHz
frequency range within the current VFO frequency.
1 Press [VFO].
2 Turn the Tuning control or press [ ]/ [ ] to select
a frequency in which to perform the MHz Scan. If
you want to scan the entire 145 MHz frequency,
select any frequency between 145.000 and
149.995 MHz (for example, select 145.650 MHz).
Scan will operate between 145.000 MHz and
145.999 MHz.
3 Press [MHz] (1 s) to start the MHz Scan.
4 To stop the MHz Scan, press [MHz] or [PTT].
Note:
If the Fine Tuning function is ON, you cannot perform the MHz
Scan.
If you press [MONI], MHz Scan temporarily pauses. Release
[MONI] to resume scanning.
7 SCAN
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-f7e

Table of Contents