Sanyo CLT-99 Service Manual page 8

Table of Contents

Advertisement

ADJUSTMENT
10 CH Frequency List of Cordless Telephone
HANDSET
CH (No.)
Tx Freq.
Rx Freq.
(MHz)
1
49.730
30.050
2
49.845
30.100
3
49.860
30.125
4
49.770
30.150
5
49.875
30.175
6
49.830
30.200
7
49.890
30.225
8
49.930
30.375
9
49.990
30.325
10
49.970
30.300
1st IF : 10.695MHz
2nd IF : 455kHz
HANDSET TEST MODE SPECIFICATION
1. Overview
By operating the keyboard SW on the remote unit, the pass or fail of the completion process can be determined through the
status of the LEDs, the sound of the key monitor, etc.
2. Start up
(A) Startup of the TEST MODE by the microcomputer ports.
(i) Before power ON, set to LOW P71 (2 pin).
(ii) INITIAL CHANNEL = 10 CH VCO adjustment
(B) Startup of the TEST MODE by operation of Power ON.
(When the TEST MODE begins, a beep is heard).
(i) The TEST MODE is started up by pressing "1" and "9" keys simultaneously at power on.
(ii) INITIAL CHANNEL = 10 CH VCO adjustment
(C) In case of TEST MODE in this way, there are several ways to change the normal mode.
(i) Detect charge.
(ii) Turn off the power, and turn on the power.
3. High frequency adjustment mode/Call circuit inspection mode
(A) High frequency adjustment channel
(i) VCO ADJUSTMENT CHANNEL : 10 CH (TEST MODE startup)
Tx POWER ON / Rx POWER ON / Rx MUTE OFF
(ii) Tx ADJUSTMENT CHANNEL : 4 CH (FLASH key on)
Tx POWER ON / Rx POWER ON / Rx MUTE ON
(iii) Rx ADJUSTMENT CHANNEL : 6 CH (REDIAL/P key on)
Tx POWER ON / Rx POWER ON / Rx MUTE OFF
(B) Setting of PLL channel (01 ~ 10 CH)
(i) Press two numeric keys (01 ~ 10 : Channel No.). For example : TALK MODE 01 channel
(ii) After, the following operation setting of Tx and Rx are the same number of channel.
a. * key
Tx POWER ON
b. TALK / VOL key
Tx DATA ON, Rx MUTE ON
c. END key
Tx POWER OFF / Tx DATA OFF
(C) Volume Control
Volume Control "Loud / Normal" switch over each time the MEMORY key is pressed.
Initial volume is Normal. (Only Tx POWER ON).
(D) Rx MUTE ON / OFF
Rx MUTE ON / OFF switch over each time the CHANNEL key is pressed. (Only Tx POWER ON).
(E) Detection of battery low
BATT LED is ON.
(F) Key monitor inspection mode
(i) Each time a key is pressed, the TALK LED lights and the key monitor sounds.
(ii) Keys are pressed disorderly, and if after all keys have been pressed, the TALK LED lights for approximately 0.5 sec.
and a beep is heard.
CLT-99/SS (S/M) 6
8
BASE STATION
Rx Local
Tx Freq.
Rx Freq.
(MHz)
Freq. (MHz)
(MHz)
(MHz)
19.355
30.050
49.730
19.405
30.100
49.845
19.430
30.125
49.860
19.455
30.150
49.770
19.480
30.175
49.875
19.505
30.200
49.830
19.530
30.225
49.890
19.680
30.375
49.930
19.630
30.325
49.990
19.605
30.300
49.970
-12-
BASE STATION TEST MODE SPECIFICATION
1. Start Up
(A) Start up of the Test mode by the microcomputer ports.
Rx Local
Before power ON, select the microcomputer ports : 36 pin (high or low), 59 pin -53 pin (short or open),
Freq. (MHz)
62 pin - 54 pin (short or open).
39.035
36 pin
39.150
(TEST)
39.165
HIGH
39.075
39.180
39.135
LOW
39.195
39.235
(B) Start up of the TEST MODE by operation of power ON
39.295
(i) Continue pressing ' PAGE/INT" key.
39.275
(ii) Supply the power keeping "(a)".
(iii) Set the TONE/PULSE switch to PULSE.
(iv) Set the TONE/PULSE switch to TONE.
(v) Release "PAGE/INT" key.
Test mode will be Handset Call Status. (Channel
In case of Test mode in this way, there are several ways to change the usual mode.
(i) Detect charge.
(ii) Turn OFF the power
2. The states of test mode
(A) Change state, press "#" key and then press numeric key (1 or 2 or 3).
For example: Intercom Call
Or each time you press the "SPEAKER" key, the state No. is increased.
The states of test mode
State
State Name
(i)
Handset Call
(ii)
Base Station Call
(Speaker phone)
0 and 1 key
(iii)
Intercom Call
* NOTE: INTERCOM SPEAKERPHONE measurement is not possible at this lest mode.
12/1/00, 3:17 PM
59 pin-53 pin
62 pin-54 pin
(*key)
(Flash key)
Open
Open
Usual Mode
Open
Open
Test Mode (Handset Call)
Short
Open
Test Mode (Handset Call)
Open
Short
Test Mode (Handset Call)
10 CH)
"#", "3".
Condition
While "REDIAL/P" key is pressed, Tx DATA turns ON and Tx MUTE turns ON.
(Set at PULSE mode & RINGER OFF)
By pressing "PAGE/INT" key each time, DTMF is sent ("1", "2" ...).
By pressing "REDIAL" key, PULSE dial is sent. (Set at TONE mode)
Rx MUTE is ON. While "REDIAL/P" key is pressed, Tx DATA turns ON and
Tx MUTE turns ON.
While an incoming call is detected, CHARGE/IN USE LED blinks and "RING"
is heard. (Set at TONE mode)
-13-
Mode
Channel
-
10 CH
4 CH
6 CH
LED
CHARGE/IN USE
CHARGE/ IN USE
& SPEAKER
INTERCOM &
SPEAKER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clt-99ss

Table of Contents