Advertisement

Quick Links

FIRE TABLES
O
WNER
When an appliance is for connection to a fixed piping system, the installation must conform with local
codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54,
International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA B149.1, or Propane
WARNING
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
An LP-cylinder not connected for use shall not
be stored in the vicinity of this or any other
appliance.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the
appliance and immediately call your gas
supplier or fire department.
Report # 527-O-01-5
ANSI Z21.97-2012/CSA 2.41-2012 "Outdoor Decorative Gas Appliances."
CGA 2.17-M91 (R2009) "Gas-Fired Appliances for Use at High Altitudes."
'
M
S
ANUAL
WARNING:
Storage and Handling Code, B149.2, as applicable.
For Outdoor Use Only.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Read the installation, operat-
ing and maintenance instructions thoroughly
before installing or servicing this equipment .
This appliance is designed as an "attended
appliance". Adults must be present when the
unit is operating. DO NOT leave this unit
burning when unattended. If this product is
left burning unattended it may cause damage
or serious injury.
INSTALLER & CONSUMER
These instructions MUST be retained
with this appliance.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or
home.
2014 Firetainment, Inc. 4/14 Rev 1

Advertisement

Table of Contents
loading

Summary of Contents for Firetainment FIRE TABLES

  • Page 1 Never use this appliance in an enclosed space such as a camper, tent, car or home. Report # 527-O-01-5 ANSI Z21.97-2012/CSA 2.41-2012 “Outdoor Decorative Gas Appliances.” CGA 2.17-M91 (R2009) “Gas-Fired Appliances for Use at High Altitudes.” 2014 Firetainment, Inc. 4/14 Rev 1...
  • Page 2: Table Of Contents

    Owners’s Manual For info call: 1 . 888 . 769 . 3444 Page 2 Cover – Important Safety Information.…………………………………………………………………………………………..…….1 Table of Contents…….…………………..………………………………………………………………………………………………2 Important Safety Information Clearances to Combustibles………………………………………………….…………………………...………………...2 Installation & Preparation Guidelines……………………………...………...…………….……………………....3-4 Installation Information Connecting the Gas to the Fire table……….………………………….………………………...……………………….5-7 Instructions Operating Instructions……………………………………………………………………………………………….………...8 Lighting Instructions……………………………………………….………………………………….………….……………8...
  • Page 3: Important Safety Information

    Owner’s Manual For info call: 1 . 888 . 769 . 3444 Page 3 IMPORTANT SAFETY INFORMATION INSTALLATION AND PREPARATION SAFETY GUIDELINES  The fire table is for outdoor use only. DO NOT install or use this fire table inside a building, garage, or any other enclosed area including recreational vehicles and/or boats.
  • Page 4 Owner’s Manual For info call: 1 . 888 . 769 . 3444 Page 4 IMPORTANT SAFETY INFORMATION Cont. INSTALLATION AND PREPARATION SAFETY GUIDELINES The LP-gas supply cylinder to be used must have the following guidelines:  Constructed and marked in accordance with the U.S.D.O.T. Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commision, CAN/CSA-B339, as applicable.
  • Page 5: Clearances To Combustibles

    Owner’s Manual For info call: 1 . 888 . 769 . 3444 Page 5 INSTALLATION INFORMATION CONNECTING THE GAS TO THE FIRE TABLE BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY INFORMATION CONTAINED IN THIS OWNER’S MANUAL, INCLUDING:  Pre-Installation and fire table Preparation Safety Guidelines (pages 3 &...
  • Page 6: Instructions

    Owner’s Manual LP GAS CONNECTION INFORMATION Page 6 INSTALLERS OF ANY FIRETAINMENT PRODUCTS MUST BE LICENSED, CERTIFIED, AND FAMILIAR WITH ALL LOCAL CODE REQUIREMENTS ALL TABLES COME PRE-ASSEMBLED FOR LP APPLICATIONS (BELOW). PLEASE REVIEW THE INFOR- MATION ON THE NEXT PAGE TO CONVERT YOUR FIRETAINMENT TABLE TO BURN NATURAL GAS.
  • Page 7: Instructions

    Owner’s Manual NATURAL GAS CONNECTION INFORMATION Page 7 ANY MODIFICATIONS OR INSTALLERS OF ANY FIRETAINMENT PRODUCTS MUST BE LICENSED, CERTIFIED, AND FAMIL- IAR WITH ALL LOCAL CODE REQUIREMENTS ALL TABLES COME PRE-ASSEMBLED FOR LP APPLICATIONS. PLEASE REVIEW THE INFORMATION ON THIS PAGE TO CONVERT YOUR FIRETAINMENT TABLE TO BURN NATURAL GAS.
  • Page 8: Operating Instructions

    Owner’s Manual For info call: 1 . 888 . 769 . 3444 Page 8 OPERATING INSTRUCTIONS We recommend that before you install your fire table you familiarize yourself with the control valve layout. This will help you be more confident when operating your fire table when fully installed (see figures below for typical control positions).
  • Page 9: Operating Information

     BE CAREFUL not to scratch the bottom of the burner pan with the lazy Susan mount legs, this is not cov- ered under the Firetainment warranty. Warranty does not cover scratches or rust caused by scratches.  DO NOT clean any of the table’s surfaces with abrasive materials, this will potentially scratch a finished...
  • Page 10 Owner’s Manual For info call: 1 . 888 . 769 . 3444 Page 10 ADDITIONAL WARNINGS  MUST have a 1/2” clearance from the bottom of the base to the floor for ventilation.  DO NOT reach under burner pan while hot to disconnect or turn off gas connection until the table has completely cooled.
  • Page 11: Care & Maintenance

    If you have any questions on how to clean your unit, please feel free to contact Firetainment Inc. at 1.888.769.3444.
  • Page 12 This warranty does not apply to any damage caused by shipping, accidents, fading, staining, natural weathering, misuse, alterations or repairs. No other person is authorized to assume liability on behalf of Firetainment, and in no event shall Firetainment be liable for any contributory or subsequent damage related to the merchandise purchased from Firetainment.
  • Page 13: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE Page 13 POSSIBLE CAUSE SOLUTION NOTES PROBLEM Propane tank does not fill Propane tank was not purged Take it to an authorized propane The purging process requires that properly station and re-purge the propane all air is removed from the propane tank tank prior to the first fill The OPD float valve on the pro-...
  • Page 14: Installation / Granite Handling

    Fire Table Installation / Granite Handling Instructions Page 14 Remove the assembled base and all of the other components/accessories from the base box that was shipped on a pallet. Make sure all components are within the box needed for the table assembly. Then position the granite crate in a manner in which it is close to where the table will be assembled, this is due to the weight of the granite and the handling instructions referenced below.
  • Page 15: Installation / Granite Handling

    Fire Table Installation / Granite Handling Instructions Cont. Page 15 BURNER PAN AND CONTROL VALVE INSTALLATION 1. Remove the burner pan and valve assembly from its box (All burners are setup for propane when they leave our facility; please refer to the Owner’s Manual for natural gas conversion instructions). Make sure the knob is turned all the way to the right.
  • Page 16 Owner’s Manual 888 . 769 . 3444 Firetainment.com contact@firetainment.com...