Summary of Contents for QUANTA 230W Security Floodlight

  • Page 1 230W Security Floodlight QUANTA V4.0 -10/11 IQ-NALP-180-300-D-GR...
  • Page 2: General Information

    SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. This unit has a dual light level operation. During darkness the lamp will illuminate constantly at a user defined light level until it detects movement, then the unit will switch to full brightness for a user defined time on period.
  • Page 3: Installation

    SECTION THREE INSTALLATION After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 240V 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to switch the power to the unit ON &...
  • Page 4: Operation And Testing

    SECTION FOUR OPERATION AND TESTING WALK TESTING PROCEDURE The sensor will rotate from left to right. Adjust the sensor to point in the desired direction. See diagram A & H for the different sensor patterns and lens masking. See diagram C & I for the adjustment controls. Set the Time,Dusk and Dim control as follows : TIME - Fully anti-clockwise DUSK - Fully clockwise Dim - Fully anti clockwise...
  • Page 5 TOP VIEW Degrees SIDE VIEW TIME TIMER 2.5m Less sensitive More sensitive...
  • Page 6: Installation Diagram

    INSTALLATION DIAGRAM...
  • Page 7: Connection Diagram

    CONNECTION DIAGRAM Wall Plate Cable Entry Blue Green/Yellow Brown Connect the mains cable to N,E & L connections in the terminal block Match the three pins on the unit to the wall plate.
  • Page 8 The floodlight can be adjusted to angle the beam to cover the required area CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY. LENS MASKING DIAGRAM The arrows indicate the front of the detection area in that section of the sensor Engraving indicates the approx detection...
  • Page 9: Special Functions

    ADJUSTMENT KNOBS TIMER CONTROL MODE The DUSK TIME setting controls how long the unit remains illuminated after dusk if the unit is set in TIMER CONTROL MODE. (See section 5). The unit can be set to illuminate between 1 and 8 hours, then it will SWITCH THE UNIT OFF until Dusk the following evening.
  • Page 10 SETTING UP FOR AUTOMATIC OPERATION. When walk tests are complete, the unit can be switched to automatic operation : The TIME setting controls how long the unit remains illuminated following activation & after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx.
  • Page 11: Technical Specifications

    SECTION FIVE TECHNICAL SPECIFICATIONS Detection Range Up to 12 metres Detection Angle 180º Power Supply 240V ~ 50Hz Maximum Switchable Load 300W Lamp Type 118mm Linear Tungsten Halogen 300W max (R7S cap) Timer Control Adjustable 1 to 8 Hrs Time On Adjustment 5 seconds - 5 minutes Lux Level Adjustment Day &...
  • Page 12: Troubleshooting Guide

    SECTION SIX TROUBLESHOOTING GUIDE PROBLEM SOLUTION o Lamp stays ON all the time at The unit may be suffering from false activation. Cover the night. sensor lens completely with a thick cloth. This will prevent the sensor from "seeing" anything. If the unit now switches o PIR keeps activating for no off after the set time duration and does not re-activate, this reason / at random.