Imperx Adapt-A-Link Family User Manual

Adapt-a-link family converters and repeaters
Table of Contents

Advertisement

Quick Links

Adapt-A-Link Manual
Adapt-A-Link Family
Converters and Repeaters
User's Manual
CONFIDENTIAL NOTICE:
Copyright © 2005, Imperx, Inc. All rights reserved.
Any unauthorized use, duplication or distribution of this document or any part thereof,
without the prior written consent of Imperx Corporation is strictly prohibited.
Imperx Inc.
1
Adapt-A-Link Manual
6421 Congress Ave.
Rev 1.0
Boca Raton, FL 33487
01.14.05

Advertisement

Table of Contents
loading

Summary of Contents for Imperx Adapt-A-Link Family

  • Page 1 CONFIDENTIAL NOTICE: Copyright © 2005, Imperx, Inc. All rights reserved. Any unauthorized use, duplication or distribution of this document or any part thereof, without the prior written consent of Imperx Corporation is strictly prohibited. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave.
  • Page 2: Table Of Contents

    MRC – RS422 to Medium Camera Link Converter ..........61 Chapter 3 – Adapt-A-Link Warranty..................68 OPERATING INSTRUCTIONS .................. 69 WARRANTY ....................... 69 Appendix 1– Cables and Connectors ..................70 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487...
  • Page 3 Figure 25. 100 pin female box jack - TYCO/AMP # 787169-9........... 71 Figure 26. 26 pins Camera Link female box jack – 3M-10226-55G3VC........72 Figure 27. 24 pins DVI female box jack – DVI-D, Molex............72 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave.
  • Page 4 Table 29b. Pin assignments for the second 100 pins input connector.......... 65 Table 30a. Pin assignments for the first (Base) 26 pins output connector........66 Table 30b. Pin assignments for the second (Medium) 26 pins output connector......67 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave.
  • Page 5: C Hapter 1 - Introduction

    Medium Camera Link to RS422 Converter RS422 to Base Camera Link Converter RS422 to Medium Camera Link Converter LVDS to Base Camera Link Converter LVDS to Medium Camera Link Converter Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487...
  • Page 6: General Description

    To overcome this obstacle, IMPERX has developed a series of interface adapters, the Adapt-A- Link family, which convert the interface signals from cameras using DVI, LVDS (RS644) and RS422 standards to a set of signals fully compatible to the Base or Medium configuration Camera Link interface.
  • Page 7: Technical Specifications

    4 LVDS control inputs 1 LVDS data clock 1 RS232 serial interface Clock 66 MHz max Power 6.0 VDC, 300 mA Dimensions 5.0" x 3.0" x 1.5" Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 8 1 RS422 data clock 1 RS232 serial interface Output Base Camera Link Clock 33 MHz max Power 6.0 VDC 300 mA Dimensions 5.0" x 3.0" x 1.5" Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 9 1 LVDS data clock 1 RS232 serial interface Output Medium Camera Link Clock 66 MHz max Power 6.0 VDC, 500 mA Dimensions 5.0" x 3.0" x 1.5" Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 10: Chapter 2 - Adapt-A-Link Features

    Adapt-A-Link Manual Chapter 2 – Adapt-A-Link Features Adapt-A-Link Features This chapter discusses the adapters features and their use. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 11: Dvicl - Dvi To Camera Link Converter

    Detailed views of the DVI input and Camera link output connectors are shown in Appendix 1. Figure 2. DVICL Connectivity Figure 3. DVICL front (top) and back (bottom) views. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 12: Table 1. Pin Assignments For Dvi Interface

    T.M.D.S. Data 5 - T.M.D.S. Data 5 + T.M.D.S. Clock Shield + T.M.D.S. Clock + T.M.D.S. Clock 5 - Table 1. Pin assignments for DVI interface. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 13: Table 2. Dvi-Cl Supported Video Resolution And Data Rates

    " Dual Output Mode", controlled by "M ode" switch. 5. Mo de Switch: Switches operating mode betwee n Single and Dual output mode: Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 14 If this does not resolve the problem, input signal bandwidth may be: a. Too high for single output mode, use dual output mode, b. Below minimum Camera Link clock rate, increase pixel/refresh rate. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave.
  • Page 15: Clcl - Camera Link Repeater

    Camera Link output connectors. Detailed views of the Camera link connectors are shown in Appendix 1. Figure 4. CLCL Connectivity Figu re 5 . CLCL fro nt (top) and back (b ottom) view Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 16: Table 3A. Pin Assignments For The First (Base) 26 Pins Input Connector

    - CC 4 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 3a. Pin assignments for the first (Base) 26 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 17: Table 3B. Pin Assignments For The Second (Full) 26 Pins Input Connector

    + Z 3 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 3b. Pin assignments for the second (Full) 26 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 18: Table 4A. Pin Assignments For The First (Base) 26 Pins Output Connector

    - CC 4 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 4a. Pin assignments for the first (Base) 26 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 19: Table 4B. Pin Assignments For The Second (Full) 26 Pins Output Connector

    2. If the unit generates an output signal but im age is corrup ted or unstable check the cables and make sure they are fir mly attached. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487...
  • Page 20: Lvlv - Lvds Repeater

    Detailed views of the LVDS connectors are shown in Appendix 1. Figure 6. LVLV Connectivity. gure 7. LVL V fron t (t op) a back (b ottom) view Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 21: Table 5. Pin Assignments For The 100 Pins Input Connector

    - ENABLE IN 3 6.0 VD C GROUN + PIXEL CLOCK IN GROUND - PIXEL CLOCK IN GROUND Table 5. Pin assignments for the 100 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 22: Table 6. Pin Assignments For The 100 Pins Output Connector

    - ENABLE OUT 3 6.0 VDC GROUND + PIXEL CLOCK OUT GROUND - PIXEL CLOCK OUT GROUND Table 6. Pin assignments for the 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 23 RS232 (default) to SERIAL DATA with a set of jumpers located inside the box. Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 10. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain.
  • Page 24: Bcl - Base Camera Link To Lvds Converter

    Detailed views of the Camera link input and LVDS output connectors are shown in Appendix 1. Figure 8. BCL Connectivity. Figure 9. B front ( top) and b (botto m) v iews. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 25: Table 7. Bit Assignments For Base Camera Link Interface

    4. FVAL - Frame Valid is defined HIGH (default) for va lid lines. 5. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for m inform ation. 6. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.).
  • Page 26: Table 8. Pin Assignments For The 100 Pins Output Connector

    OUT 3 6.0 VDC GROUND + PIXEL CLOCK OUT GROUND - PIXE L CL OCK OUT GROUND Table 8. Pin assignments for the 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 27: Table 9. Pin Assignments For The 26 Pins Input Connector

    SERIAL DATA with a set of jumpers located inside the box. Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link u nit, if two or more adapter units are used in the same chain.
  • Page 28: Bcr - Base Camera Link To Rs422 Converter

    Camera link input and RS422 output connectors are shown in ppendix 1. Figure 10. BCR Connectivity. Figure 11. B front (top ) and b (botto m) views. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 29: Table 10. Bit Assignments For Base Camera Link Interface

    4. FVAL - Frame Valid is defined HIGH (default) for va lid lines. 5. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for m inform ation. 6. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.) Imperx Inc.
  • Page 30: Table 11. Pin Assignments For The 100 Pins Output Connector

    OUT 3 .0 VDC GROU + PIXEL CLOCK OUT GROUND - PIXE L CL OCK OUT GROUND Table 11. Pin assignments for the 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 31: Table 12. Pin Assignments For The 26 Pins Input Connector

    RS232 (default) to SERIAL DATA with a set of jumpers located inside the box. Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain.
  • Page 32: Blc - Lvds To Base Camera Link Converter

    Detailed views of the LVDS input and Camera link output connectors are shown in Appendix 1. Figure 12. BLC Connectivity. Figure 13. B front (top ) and b (bott om) v iews Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 33: Table 13. Bit Assignments For Base Camera Link Interface

    4. FVAL - Frame Valid is defined HIGH (default) for va lid lines. 5. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for m informatio 6. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.) Imperx Inc.
  • Page 34: Table 14. Pin Assignments For The 100 Pins Input Connector

    + PIXEL CLOCK IN GROUND - PIXE LOCK IN GROUND Table 1 4. P in assignm ents for th e 100 pin s input con nector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 35: Table 15. Pin Assignments For The 26 Pins Output Connector

    Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in th e same chain.
  • Page 36: Brc - Rs422 To Base Camera Link Converter

    Detailed views of the RS422 input and Camera link output connectors are shown in Appendix 1. Figure 14. BRC Connectivity. Figure 15. B front (top ) and b (bott om) v iews Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 37: Table 16. Bit Assignments For Base Camera Link Interface

    4. FVAL - Frame Valid is defined HIGH (default) for valid lines. 5. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for m informatio 6. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.) Imperx Inc.
  • Page 38: Table 17. Pin Assignments For The 100 Pins Input Connector

    + PIXEL CLOCK IN GROUND - PIX EL CL OCK IN GROUND Table 1 7. P in assignm ents for the 100 pi ns input con nector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 39: Table 18. Pin Assignments For The 26 Pins Output Connector

    RS232 (default) to SERIAL DATA with a set of jumpers located inside the box. Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain.
  • Page 40: Mcl - Medium Camera Link To Lvds Converter

    26 pin Camera Link input connectors. Detailed views of the Camera link input and LVDS output connectors are shown in Appendix 1. Figure 16. MCL Connectivity. Figure 17. MCL front (top) and back (bottoms) views. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 41 Port E1 DATA 34 Port E2 DATA 35 Port E3 DATA 36 Port E4 DATA 37 Port E5 DATA 38 Port E6 DATA 39 Port E7 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 42: Table 19. Bit Assignments For Medium Camera Link Interface

    4. FVAL - Frame Valid is defined HIGH (default) for valid lines. 5. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for more information. 6. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.).
  • Page 43: Table 20A. Pin Assignments For The First 100 Pins Output Connector

    6.0 VDC GROUND + PIXEL CLOCK OUT GROUND - PIXEL CLOCK O GROUND Table 20 a. Pin assignm ents for the first 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 44: Table 20B. Pin Assignments For The Second 100 Pins Output Connector

    6.0 VDC GROUND + PIXEL CLOCK OUT 1 GROUND - PIXEL CLOCK OUT 1 GROUND Table 20b. P in a ssignments for the second 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 45: Table 21A. Pin Assignments For The First (Base) 26 Pins Input Connector

    - CC 4 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 21a. Pin assignments for the first (Base) 26 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 46: Table 21B. Pin Assignments For The Second (Medium) 26 Pins Input Connector

    RS232 (default) to SERIAL DATA with a set of jumpers located inside the box. Units sold prio r to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain.
  • Page 47: Mlc - Lvds To Medium Camera Link Converter

    Link output connectors. Detailed views of the LVDS input and Camera link output connectors are shown in Appendix 1. Figure 18. MLC Connectivity. Figure 19. MLC front (top) and back (bottom ) vi ews. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 48 Port E4 DATA 37 Port E5 DATA 38 Port E6 DATA 39 Port E7 DATA 40 Port F0 DATA 41 Port F1 DATA 42 Port F2 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 49: Table 22. Bit Assignments For Base Camera Link Interface

    4. FVAL - Frame Valid is defined HIGH (default) for valid lines. 5. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for more information. 6. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.).
  • Page 50: Table 23A. Pin Assignments For The First 100 Pins Input Connector

    - ENABLE IN 3 6.0 VDC GROUND IXEL CLOCK IN GROUND - PIXEL CLOCK IN GROUND Table 23a . Pin assign ments for the first 100 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 51: Table 23B. Pin Assignments For The Second 100 Pins Input Connector

    + PIXEL CLOCK IN 1 GROUND - PIX EL C LOCK IN 1 GROUND Table 23b. P in a ssignments for the second 100 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 52: Table 24A. Pin Assignments For The First (Base) 26 Pins Output Connector

    - CC 4 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 24a. Pin assignments for the first (Base) 26 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 53: Table 24B. Pin Assignments For The Second (Medium) 26 Pins Output Connector

    RS232 (default) to SERIAL DATA with a set of jumpers located inside the box. Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain.
  • Page 54: Mcr - Medium Camera Link To Rs422 Converter

    Camera Link input connectors. Detailed views of the Camera link input and RS422 output connectors are shown in Appendix 1. Figure 20. MCR Connectivity. Figure 21. MCR front (top) and back (bottoms) views. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 55 Port E1 DATA 34 Port E2 DATA 35 Port E3 DATA 36 Port E4 DATA 37 Port E5 DATA 38 Port E6 DATA 39 Port E7 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 56: Table 25. Bit Assignments For Medium Camera Link Interface

    10. FVAL - Frame Valid is defined HIGH (default) for valid lines. 11. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for m inform ation. 12. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.).
  • Page 57: Table 26A. Pin Assignments For The First 100 Pins Output Connector

    - ENABLE OUT 3 6.0 VDC GROUND IXEL CLOCK OUT GROUND - PIXEL CLOCK OUT GROUND Table 26 a. Pin assignm ents for the first 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 58: Table 26B. Pin Assignments For The Second 100 Pins Output Connector

    + PIXEL CLOCK OUT 1 GROUND - PIX EL CL OCK OUT 1 GROUND Table 26b. P in a ssignments for the second 100 pins output connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 59: Table 27A. Pin Assignments For The First (Base) 26 Pins Input Connector

    - CC 4 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 27a. Pin assignments for the first (Base) 26 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 60: Table 27B. Pin Assignments For The Second (Medium) 26 Pins Input Connector

    RS232 (default) to SERIAL DATA with a set of jumpers located inside the box. Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain.
  • Page 61: Mrc - Rs422 To Medium Camera Link Converter

    Camera Link output connectors. Detailed views of the RS422 input and Camera link output connectors are shown in Appendix 1. Figure 22. MRC Connectivity. Figure 23. MRC front (top) and ba ck (b ottom ) vie Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 62 Port E0 DATA 33 Port E1 DATA 34 Port E2 DATA 35 Port E3 DATA 36 Port E4 DATA 37 Port E5 DATA 38 Port E6 Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 63: Table 28. Bit Assignments For Base Camera Link Interface

    10. FVAL - Frame Valid is defined HIGH (default) for va lid lines. 11. LVAL, DVAL and FVAL can be independently inverted with a set of jumpers located inside the box. Please contact Imperx for m information. 12. CONTROL (0 – 3) – 4 control signals (usually trigger, integration, etc.).
  • Page 64: Table 29A. Pin Assignments For The First 100 Pins Input Connector

    - ENABLE IN 3 6.0 VDC GROUND IXEL CLOCK IN GROUND - PIXEL CLOCK IN GROUND Table 29a . Pin assign ments for the first 100 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 65: Table 29B. Pin Assignments For The Second 100 Pins Input Connector

    + PIXEL CLOCK IN 1 GROUND - PI XEL C LOCK IN 1 GROUND Table 29b. P in a ssignments for the second 100 pins input connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 66: Table 30A. Pin Assignments For The First (Base) 26 Pins Output Connector

    - CC 4 - PAIR 11 Inner Shield Inner Shield Inner Shield Inner Shield Table 30a. Pin assignments for the first (Base) 26 pins outp ut connector. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 67: Table 30B. Pin Assignments For The Second (Medium) 26 Pins Output Connector

    . Units sold prior to October 1, 2004 do not support RS232 interface. Please contact Imperx for more information. 8. 6.0 VDC OUT - Provides power (if needed) for the next Adapt-A-Link unit, if two or more adapter units are used in the same chain. Each unit can provide 1000 mA MAX.
  • Page 68: Chapter 3 - Adapt-A-Link Warranty

    Adapt-A-Link Manual apter 3 – Adapt-A-Link Warranty Adap t-A-Link W arranty This chapter discusses the adapters’ warranty and operating instructions. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 69: Operating Instructions

    Imperx’s standard warranty, which is 1 (one) year parts nd labor. Do not open the box of the unit. Warranty voids if the unit has been open or tampered.
  • Page 70: Appendix 1- Cables And Connectors

    Adapt-A-Link Manual ppendix 1– Cables and Connectors Cables and Connectors is a ppendix provides a quick reference to cables and connectors used i n Adapt-A-Link family Adapters Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 71: Figure 24. 100 Pin Male Cable Plug - Tyco/Amp #749111-8

    B = 62.23 mm, C = 66.60 mm, D = 71.86 mm. Back shell kit TYCO/AMP # 749081-1 Figure 25. 100 pin female box jack - TYCO/AMP # 787169-9. A = 78.23 mm, B = 66.45 mm, D = 84.20 mm Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...
  • Page 72: Figure 26. 26 Pins Camera Link Female Box Jack - 3M-10226-55G3Vc

    Adapt-A-Link Manual Figure 26. 26 pins Camera Link female box jack – 3M-10226-55G3VC. Figure 27. 24 pins DVI female box jack – DVI-D, Molex. Imperx Inc. Adapt-A-Link Manual 6421 Congress Ave. Rev 1.0 Boca Raton, FL 33487 01.14.05...