JUMPER FUNCTIONS
Jumper
J1:
J2:
J3:
J4:
J1: ANTI CARJACKING MODE, 1 OR 2
There are 2 anti-carjacking modes, MODE 1 has 2 ways to enter.
a.) After turning IGN.ON the system will enter anti carjacking mode, within 10 seconds pressing remote
button 1 once or press & hold valet/reset switch for 1 sec will bypass the action of turning IGN.ON & the
system will exit anti carjacking mode. Parking lights flash & siren chirps 1x to confirm exit of anti-
carjacking mode. NOTE: If you fail to exit anti carjacking mode within 10 seconds, you can only exit by
EMERGENCY DISARMING procedure. Parking lights will flash & siren will chirp 4x for confirmation.
b.) With IGN.ON, press remote button 3 & hold for 3 seconds to activate anti carjacking mode.
MODE 2 has one way to enter anti carjacking mode, refer to procedure b.) of MODE 1.
J2: ANTI CARJACKING FUNCTION, YES OR NO
WHEN THE SYSTEM ENTERS ANTI CARJACKING MODE:
a.) From 0-15 seconds nothing happens. From 16-30 seconds LED will flash slowly. From 31-45 seconds LED
will flash fast & siren will chirp 1x every 2 seconds. From 46-70 seconds LED will flash fast & siren will chirp
1x every second. After 70 seconds siren will sound & parking lights flash continuously.
b.) After turning IGN.OFF, siren will sound & parking lights flash continuously for 3 mins. before stopping.
J3: DOOR LOCK & UNLOCK TIMER, 0.5 OR 3.5 SECONDS
You can choose between 0.5 second or 3.5 seconds for central locking signal, typically 0.5 second is used for
electronic central locking and 3.5 seconds for pneumatic central locking.
J4: PASSIVE OR ACTIVE ARMING
PASSIVE:
a.) Once alarm is disarmed if ignition is not turned on & a door is not opened, LED will flash rapidly to signify
auto re-arm is set, then after 30 seconds the system will re-arm & lock doors automatically.
b.) If ignition is not turned on LED will flash rapidly & system will automatically re-arm & lock doors 30
seconds after the last door is closed.
ACTIVE:
a.) Once alarm is disarmed if ignition is not turned on & a door is not opened, LED will flash rapidly to signify
auto re-arm is set, then after 30 seconds the system will re-arm & lock doors automatically.
b.) If a door is opened LED will stop flashing & system will remain disarmed & doors unlocked.
Jumper (ON)
www.viking-au.com/docs/acl-383-manual.pdf
Default
Jumper (OFF)
MODE 1
NO
0.5 secs
PASSIVE
Variant
MODE 2
YES
3.5 secs
ACTIVE

Advertisement