Ethernet Extender Mode Settings

Ethernet Extender mode settings are made very simple by means of a
switch at the rear panel of the Ethernet Extender. The switch has two
positions for Ethernet Extender mode settings. Refer to the table below for
more details. One device must be set to Loc and the other to Rmt when two
devices are connected.
Loc
The device operates in local mode The device operates in remote mode
Front Panel & LEDs
The LED indicators give you instant feedback on status of the Ethernet
Extender:
LEDs
State
Indication
Power on
Steady
Pwr
Pwr stands for POWER
Off
Power off
Ethernet
A valid Ethernet connection established
Steady
Lnk stands for LINK
Transmitting or receiving Ethernet data
Lnk/Act
Flashing
Act stands for ACTIVITY
Neither valid Ethernet connection established nor transmitting/receiving
Off
Ethernet data
Ethernet Connection in full duplex mode
Steady
Fdx
Fdx stands for FULL-DUPLEX
Off
Ethernet Connection in half-duplex mode
Ethernet Extender
Green The Ethernet Extender port transmitting/receiving at 1Mbps, up to 1900M
1
Amber
The Ethernet Extender port transmitting/receiving at 3Mbps, up to 1800M
The Ethernet Extender port transmitting/receiving at 5Mbps, up to
Green
2
1600M
Amber
The Ethernet Extender port transmitting/receiving at 10Mbps, up to 1400M
Green The Ethernet Extender port transmitting/receiving at 15Mbps, up to 1200M
3
Amber
The Ethernet Extender port transmitting/receiving at 20Mbps, up to 1000M
Green The Ethernet Extender port transmitting/receiving at 25Mbps, up to 800M
4
Amber
The Ethernet Extender port transmitting/receiving at 30Mbps, up to 700M
4 + 2
Amber
The Ethernet Extender port transmitting/receiving at 40Mbps, up to 600M
4 + 3
Amber
The Ethernet Extender port transmitting/receiving at 50Mbps, up to 300M
Rmt
Steady
The device operates in remote mode
Loc
Steady
The device operates in local mode
Err
Steady
Error occurred
Lnk
Steady
A valid connection established

Connecting to Power

This Ethernet Extender is a plug-and-play device. Connect the supplied AC
to DC power adaptor to the receptacle on the rear panel of the Ethernet
Extender, and then attach the plug into a standard AC outlet with a voltage
range from 100 to 240V AC.