  • Page 2: Distress Acknowledgement

    Quick DISTRESS Call 1. If off or STANDBY: press ON/OFF. 2. Open DISTRESS lid. Press the DISTRESS button seconds to transmit 3 - 2 - 1 - 3. Press DISTRESS TYPE : Distress RELEASE until RELEASE is displayed MSG. : Undesignated : Unknown Time : Unknown...
  • Page 3: What Is What

    What Is What? 1. Display. 9. TEL/DSC function switch. 2. Indicator lamps. Condition when lit: In TEL mode radiotelephone parameters are shown and Transmitting. selected. CALL: DSC (see button 9) call for you received. In DSC mode DSC parameters are shown and selected. ALARM: Alarm call received.
  • Page 4: Introduction

    Introduction Abbreviations Used in this The SKANTI TRP 1000 series is a new generation of highly inte- Manual grated MF/HF radiocommunication systems for GMDSS. These systems comply with the latest requirements within maritime MF/HF ADDR Address communication. Automatic Gain Control...
  • Page 5: Table Of Contents

    Advanced DSC Calls ............14 Contents Changing a Function ............16 Quick DISTRESS Call ............ii The Function Tree ............ 17 DISTRESS Acknowledgement ..........ii GMDSS Radiotelex Terminal ..........18 What Is What? ..............iii Introduction ..............18 Introduction ................. iv Keyboard Indicator Lamps ..........
  • Page 6: Mf/Hf Fundamental Info

    MF/HF Fundamental Info Propagation of MF and HF Radio Waves DSC (Digital Selective Calling) is an automatic calling system which allows a specific station to be contacted and made aware that a MF/HF radiocommunications provide a medium and long range station wishes to communicate with it.
  • Page 7: Basic Functions

    Setting Transmitter Power Level Basic Functions 1. Press the Shift key followed by the Power Key. Switching ON/OFF 1. Press the ON/OFF button. The output power is set to HIGH, MED or LOW. Repeat until the desired setting is reached. Setting Backlight Level 1.
  • Page 8: Manual Call Functions

    Manual Call Functions Telephony Channel Display Functions: Name of station if selected. Channel number. Soft keys LYNGBY FREQ Switches to Frequency display for viewing or altering frequencies. 4 1 8 STATION Switches to Station display for selection of another station. Steps to the next lower channel number of the station.
  • Page 9: Station Display Functions

    Station Display Functions: Name of station MMSI number of station Soft keys SELECT Selects the station and switches to Channel display for choice of channel number. STATION TABLE CANCEL Returns to Channel display without selecting the station. NAME LYNGBY CALL SIGN Selects previous station.
  • Page 10: Two-Tone Alarm Signal

    Two-tone Alarm Signal To switch to the Two Tone Alarm Signal display: Press the Shift key followed by the Alarm key. Two-tone Alarm Display Functions: Soft keys Press the START button FREQ Returns to frequency display. Starts test of the alarm signal generator. TEST seconds to send alarm Starts transmission of the two tone alarm signal.
  • Page 11: Dsc Main Buttons

    DSC Main Buttons To switch between the DSC STATUS and telephony displays: press TEL/DSC. Soft keys CHANGE DSC STATUS Changes calling watch frequencies. WATCH Switches between calling watch On/Off Distress Watch: 2 12 16 MHz Views watch frequencies. Calling Watch: 2 -- MHz VIEW FREQ Changes distress frequency used default for quick distress calls.
  • Page 12: Dsc Display Operation

    DSC Display Operation Receiving an Individual DSC Call When calling watch is on, your MF/HF set is constantly scanning the selected DSC channels for incoming DSC calls. Lift the handset and press PTT to connect to the caller. Lift HANDSET to connect Individual call received Press VIEW to read out the call.
  • Page 13: Receiving Distress Call

    Receiving DISTRESS Call When switched on, your MF/HF set is constantly scanning all DSC distress channels for incoming DSC distress calls. Distress call received Press VIEW to read out the call. VIEW ABORT Press ABORT to return to TEL screen FROM: 21900100 CALL CONTENT Time:...
  • Page 14: Calling A Ship

    Calling a SHIP Press Tx CALL Select type SHORE of call: Select a SHIP call. SHIP DISTRESS MORE Key in the nine digit MMSI number of the wanted ship. Key in the ship ACCEPT Accept the number. MMSI number < MEMORY A sub menu where a pre-programmed ship can be selected.
  • Page 15: Calling A Shore Station

    Calling a SHORE Station Press Tx CALL SHORE Select type Select a SHORE call. of call: SHIP DISTRESS MORE Key in the nine digit MMSI number of the wanted coast station. Key in the coast ACCEPT Accept the number. station MMSI number <...
  • Page 16: Address Book

    Address Book This MF/HF set is designed with self-explaining menus. The four soft keys on the right side of the display refer to the display text. Open the addr book menu. Lower left side of the display is the data area. Right side shows the Upper left side of the function of the soft keys.
  • Page 17: Using Two Control Units

    If for instance control unit #2 has sent an individual DSC call, control Using Two Control Units unit #2 is to receive and respond to the acknowledgement call that may follow. You can connect two control units to the system. However, it can If a call comes in when both control units are in the DSC Status only be controlled by one control unit at a time.
  • Page 18: Advanced Dsc Calls

    Advanced DSC Calls Extended DSC calls make it possible for you to control the call completely within the international rules, including the possibility of sending data or fax from optional equipment connected to your MF/ HF set. To start an extended call, select EXTENDED as the ‘Type of call’ in the Tx menu below, and then continue in the Extended calls menu on next page.
  • Page 19 EXTENDED Tx call started from “EXTENDED” in the table on the previous page. Enter correct data instead of examples shown in italics : Type of call Address Options Category Telecom 1 Telecom 2 Add. msg. Ackn. INDIVIDUAL Shore: 001234567 No info: Call shore station Routine SSB telephony No info Shore phone: 98765432: Call Phone No.
  • Page 20: Changing A Function

    Changing a Function There are a large number of function settings available, selectable from a function tree, see the next page. This chapter only deals with the principles of how to use the functions tree. An example: Changing the Display Contrast Press SHIFT and FUNC to enter function menu.
  • Page 21: The Function Tree

    The Function Tree Menu Submenu Level 1 Submenu Level 2 Parameters User Display Contrast 0 to 7. High Contrast = 7 Sound Earpiece level Attenuation Level 0 - 15 Alarm level Attenuation Level 0 - 15. Version SW versions for all modules Print DSC Printer On/Off Config...
  • Page 22: Gmdss Radiotelex Terminal

    GMDSS Radiotelex Terminal Introduction The GMDSS Radiotelex Terminal is an option used for handling ‘phasing’ state by transmitting an appropriate control character. After transmission/reception of telex messages over radio. The terminal having verified the other station’s identity both stations will proceed consists of a printer and a keyboard, connected to the transceiver to ‘traffic’...
  • Page 23: Keyboard Indicator Lamps

    Over (F8): Changes the direction of an ARQ connection. Keyboard Indicator Lamps ‘Standby’ Steady light indicates that the terminal is Break (F9): Terminates a connection. ready. Responds by printing ‘Breaking connection’. Flashing light indicates that the printer is off If pressed during transmission of an edited or out-of-paper or the modem is busy/ message this is terminated.
  • Page 24: Switching On

    message may now be transmitted by pressing carriage return (¬ Switching On Enter) followed by the message to be transmitted, either typed in Press F10 and switch on the printer (The ‘Select’ printer indicator directly from the keyboard, or recalled from the text memory by must be on).
  • Page 25: Receiving A Message

    The process may be repeated if ‘N’ is pressed; the modem set-up Receiving a Message mode is left if ‘Y’ is pressed. Reception is possible whenever the terminal is on, indicated by steady light in the ‘Standby’ keyboard indicator. The radio must be The answer back of the modem is generated by combining the 5-digit set to telex mode and to the desired working channel.
  • Page 26: Example Of Fec Transmission

    Example of FEC Transmission Example of ARQ Transmission to a Assuming the GMDSS telex terminal is in Standby and the radio is Coast Station set up to telex mode and to the desired frequencies following a DSC When the GMDSS telex terminal is on, indicated by the ‘Standby’ Distress alert call, proceed as follows: keyboard indicator lamp, and the radio is set up to the desired working channel (and, if requested by the coast station, free signal...
  • Page 27 Send own answer-back by pressing the DE key: 123456789 abcd x The message is now transmitted by pressing carriage return (¬ Enter) followed by the message to be transmitted, either typed in directly from the keyboard, or recalled from the text memory by pressing the MESSAGE key: this message is typed in directly from the keyboard or recalled from the text memory.
  • Page 28 SKANTI A/S Lautrupvang 4 A DK-2750 Ballerup, Denmark Phone: +45 44 74 84 00 Fax: +45 44 74 84 01 Telex: 37292 skanti dk E-mail: skanti@skanti.dk http://www.skanti.dk...