concerning service of Atwood
CAUSE
BLOWER DOES NOT RUN
Temperature selector out of place --------------------Re-set to desired position
Thermostat wires broken or disconnected ----------Not covered under warranty.
Heat anticipator burned out --------------------------Dead short (not covered under warranty). Repair short and then replace
No continuity through thermostat with
contacts closed and switch on. ----------------------Replace thermostat.
Continuity through thermostat with
contacts closed and switch on. ----------------------• Check and reestablish power to thermostat
FURNACE DOES NOT CYCLE PROPERLY
Furnace cycles too quickly ----------------------------Move anticipator to a higher amp setting to lengthen cycle. NOT covered
High temperature variance ----------------------------Move anticipator to a lower amp setting to shorten cycle. NOT covered under
Note: When the anticipator is set properly and the heating system has operated for a few hours, the furnace should
cycle 5-6 time per hour.
®
products by service technicians who have successfully completed
®
products to 866-869-3118 option 5 before proceeding.
thermostat.
Faulty relay drawing more than 1 amp. Replace relay and thermostat. Covered
under warranty.
• Reset tripped circuit breaker.
• Correct poor ground.
• Correct any loose wires.
• Replace defective relay.
• Replace defective motor.
under warranty.
Thermostat located too close to a heat duct. Move thermostat or duct outlet.
NOT covered under warranty.