Kenmore 625.343400 Owner's Manual page 5

Multi-purpose water filter housing
Table of Contents

Advertisement

TYPICAL INSTALLATIONS / TOOLS AND MATERIALS NEEDED
FIG. 1
INSTALLATION ON COPPER PLUMBING USING COMPRESSION FITTINGS
optional shutoff valve
WATER
IN
Note: Be sure to allow a minimum space of 1–1/2"
under the filter for removing the sump, to change the
cartridge.
SOLDERED COPPER INSTALLATION
FIG. 2
(OBSERVE FIG. 1 NOTES)
WATER
IN
3/4" copper
optional shutoff valve
pipe, as req'd.
– MATERIALS AND TOOLS NEEDED –
(see page 6)
THREADED INSTALLATION
FIG. 3
(OBSERVE FIG. 1 NOTES)
WATER
IN
3/4" nipple
optional shutoff valve
– MATERIALS AND TOOLS NEEDED –
(see page 7)
apply several
wraps of
Teflon tape
INLET
3/4" NPT
adaptor,
3/4" NPT x sweat
(apply several wraps of
Teflon tape to threads)
3/4" hex nipple (2)
union fitting (2)
3/4" pipe, as required
5
nut
brass
ferrule
compression
adaptor
– MATERIALS AND TOOLS NEEDED –
" 2 compression adaptors, 3/4" NPT x comp.
(compression end to fit existing copper pipe)
Note: Sears has an installation kit available that
fits 1/2" (5/8" O.D.) and 3/4" (7/8" O.D.) pipe
sizes, Item No. 42–34346.
" Teflon tape
" tubing cutter
" sandpaper or emery–cloth
" 2 wrenches, either open end or adjustable
jaw, size to fit compression adaptors
UNDERSINK INSTALLATION
FIG. 4
(FILTERING WATER TO 1 FAUCET)
OPTIONAL
mounting bracket,
Sears Item No.
SINK
42–34348
hot
cold
shutoff valve
Note: To change the
filter cartridge, you
OPTIONAL
must turn off the
installation kit,
water.
A
nearby
Sears Item No.
shutoff valve is con-
42–34347
vienent. Most sinks
already have shutoff
(also see kit
valves on the supply
above)
pipes.
Note: Be sure to allow a minimum space of
1–1/2" under the filter for removing the sump,
to change the cartridge.
FILTERED
WATER

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents