Advertisement

Quick Links

Description
Power Rating
Remarks
Control
Rated Power 3 Phases
15kW AC1
(3 x 5kW)
Rated Voltage 3 Phases
400V 3N~
Rated Power Single Phase
9kW AC1
Rated Voltage Single Phase
230V 1N~
Frequency
50/60Hz
Switching capacity per phase
21A
Sauna temperature range
40-110°C
Maximum session time
4, 6, 12, 18, 24h
Restrictions
apply according
(preset)
to IEC/EN
60335-2-53
Dimensions INNOVA S types
User Interface
(W) 180 x (H)
105 x (D) 31
Power Controller
(W) 265 x (H)
245 x (D) 75
Dimensions INNOVA B types
(W) 265 x (H)
245 x (D) 75
Weight INNOVA S types
User Interface
120g
Power Controller
1500g
Weight INNOVA B types
1600g
Description
Remarks
Sensor
Temperature Sensor with fuse
Bench Sensors
Bench Temperature Sensor
Optional
Bench Combined Temperature -
Optional
Humidity Sensor
www.sawo.com
Subject to change without notice.
info@sawo.com
Description
Power Rating
Remarks
Steamer
Rated Power 3 Phases
5kW AC1
Rated Power Single Phase
3kW AC1
Rated Voltage
230V 1N~
Switching capacity
21A (3 Phases),
13A (1 Phase)
Maximum sauna temperature
80°C or *55°C
* Depending
for steamer operation
on the type of
Sensor 2.
Automatic water filling
Optional
Optional
Automatic drain valve
Cabin Light
Rating
230V 1N~,
100W AC1
Dimmer optional
Optional
Fan
(with speed
Rating
230V 1N~, 0.5A
control)
Description
Power Rating
Remarks
Power Extension Unit
Rated Power 3 Phases
15kW AC1 (3 x
Additional
Power expansion
5kW)
to maximum of
Rated Voltage 3 Phases
400V 3N~
30kW
Frequency
50/60Hz
Switching capacity per phase
21A
CONTROLS
INSTRUCTIONS MANUAL
ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Control Unit and is the answer not in the manual?

Questions and answers

Summary of Contents for Innova Control Unit

  • Page 1 Automatic water filling Optional apply according Optional (preset) Automatic drain valve to IEC/EN 60335-2-53 Cabin Light Dimensions INNOVA S types Rating 230V 1N~, User Interface (W) 180 x (H) 100W AC1 105 x (D) 31 Dimmer optional Power Controller (W) 265 x (H)
  • Page 2: Table Of Contents

    Table of Contents 1. Introduction of the Innova Controls 1.1 Precautions 2. Operating Instructions 2.1 Quick Start 2.2 Direction of Use 2.2.1 Heater on 2.2.2 Heater off 2.2.3 Pre-run Button 2.2.4 Setting Mode 2.2.5 Dimmer Light 2.2.6 Fan 2.2.7 Cabin Light Button 2.2.8 Key Pad Lock...
  • Page 3: Introduction Of The Innova Controls

    Buttons and States (Illustration) LED indicators LED display Congratulations on your purchase of Innova Control Unit! Light Innova Control Unit is developed to enhance your sauna bathing with a Power variety of interactive tasks. It can adjust temperature, humidity, Pre-run Timer Mode ventilation and light luminosity (advanced model) in your sauna.
  • Page 4: Direction Of Use

    Lock the key pad by pressing the up and the session time (*not all models have all When the control unit is in the pre-run state, Press the on/off button to activate the down arrow keys at the same time for more the same features).
  • Page 5: Water Refill

    The automatic drain function can be In the manual fill, the alarm beeps and enabled or disabled when the control unit is “FILL” will be displayed as long as the user in “OFF” mode. Long press the mode fills the tank.
  • Page 6: Assembly And Installation

    Assembly and Installation Please Note: The Innova Control Unit is composed of the The Innova Control Unit is designed to moni- Fig.2 Make sure you mount the temperature sensor with Innova Interface (Separate or Built-in), Power tor and regulate the functions of the electric...
  • Page 7: Power Controller Board

    However, if the heater is more than 200mm Warning from the wall, place the sensor to the Do not embed the control unit into the wall, because it may lead to overheating of the unit and cause damage! Sensor location with heaters...
  • Page 8: Maximum Session Time

    Door Switch 200mm from the wall SENSOR 2 (Optional) Fig.10 If the control unit is for other than house- is not open for long periods of time when A I R V E N T Fig.11 hold use, the sauna door shall be fitted with the heater is on.
  • Page 9: Installation For Separate Interface

    Temperature fuse is Check the wire between the sensor and the defective. control unit. It has probably overheated. The reason for it needs to be discovered before using the sauna again. A new sensor is needed. If no problem can be found, contact the retailer.
  • Page 10: The Sauna Room

    The Sauna Room Climate of the Sauna Room The climate inside the Sauna Room can be The control unit is working fine, but the The steamer is on and “dry” is displayed, monitored with a dedicated sauna sensors. How to use the Sauna even though there is plenty of water in the heater does not turn on.

Table of Contents